This manual contains important information for safe use and handling of this vacuum cleaner. Disregard of this
manual before start up, use and maintenance may cause damage or danger to persons or material. The USER
must be trained in using the machine – before any use. This manual must be stored with the machine, accessible
to all users.
111 253 000 - 230V
111 253 500 - 120V
Professional Flooring
Technology
Janser GmbH
Böblinger Straße 91
D-71139 Ehningen
Telefon 07034 / 127-0
Telefax 07034 / 8838
info@janser.com
www.janser.com
09-2021

Advertisement

loading
Need help?

Need help?

Do you have a question about the CLEVER II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Janser CLEVER II

  • Page 1 INSTRUCTION MANUAL Mixing Station CLEVER II with Stirring Device R1900 – 230 V with Stirring Device R1800 – 120 V Order-No. 111 253 000 - 230V Order-No. 111 253 500 - 120V Professional Flooring Technology Janser GmbH Böblinger Straße 91...
  • Page 2 Mixing Station CLEVER II with Stirring Device R1900 / R1800 - 2 -...
  • Page 3: Table Of Contents

    Mixing Station CLEVER II with Stirring Device R1900 / R1800 CONTENT 1 Safety 2 Product Information 3 Preparation 9-12 4 Operation 13-18 5 Storage 6 Disposal 7 Maintenance - 3 -...
  • Page 4: Safety

    Mixing Station CLEVER II with Stirring Device R1900 / R1800 1. SAFETY INSTRUCTIONS SYMBOLS WARNING The following show symbols used for the machine. Be sure that you understand their meaning before use. To reduce the risk of injury read the instructions manual carefully before use Danger: Risk of injury and equipment damage.
  • Page 5 Mixing Station CLEVER II with Stirring Device R1900 / R1800 1. SAFETY INSTRUCTIONS 2) ELECTRICAL SAFETY a) Power tool plugs must match the outlet. Never modify the plug in any way. Do not use any adapter plugs with earthed (grounded) power tools.
  • Page 6 Mixing Station CLEVER II with Stirring Device R1900 / R1800 1. SAFETY INSTRUCTIONS 3) PERSONAL SAFETY a) Stay alert, watch what you are doing and use common sense when operating a mixer. Do not use a mixer while you are tired or under the influence of drugs, alcohol or medication.
  • Page 7: Product Information

    Mixing Station CLEVER II with Stirring Device R1900 / R1800 2. PRODUCT INFORMATION 2.1 SPECIFICATIONS Stirring device R1900 R1800 Order-No. 111 252 100 111 252 550 Power Supply 230 V 120 V Motor Power 1900 W 1800 W 1 gear: 150-300 rpm...
  • Page 8 Mixing Station CLEVER II with Stirring Device R1900 / R1800 2. PRODUCT INFORMATION 2.4 CONTROL ELEMENTS Part list Base bracket Operating handle Support tube Plum blossom knob Dust cover plate (optional) Pour material mouth Mixing barrel Barrel hoop Pedals - 8 -...
  • Page 9: Preparation

    Mixing Station CLEVER II with Stirring Device R1900 / R1800 3. PREPARATION STEP 1 FIG 1 WHEEL MOUNTING As shown in FIG 1, 2 x wheels with brake at th back 2 x wheels with no brake at the front...
  • Page 10 Mixing Station CLEVER II with Stirring Device R1900 / R1800 3. PREPARATION Step 3: As shown in figure III, 1. ) disassemble the junction plate firstly, 2. ) disassemble the dust over by the socket head wrench, 3. ) Take outer the mixer carton from the barrel.
  • Page 11 Mixing Station CLEVER II with Stirring Device R1900 / R1800 3. PREPARATION Step 4: As shown in figure IV, 1. ) take out the inner hexagon screw from the mixer, 2. ) assemble the mixer to the junction plate in order of 1~4 as shown in the diagram and tighten by the socket hexagon wrench.
  • Page 12 Mixing Station CLEVER II with Stirring Device R1900 / R1800 3. PREPARATION Dust suction tube Dust hole Step 5: As shown in figure V, 1. ) Put back the dust cover as the figure showes, tighten the screws by the socket head wrench.
  • Page 13: Operation

    Mixing Station CLEVER II with Stirring Device R1900 / R1800 4. OPERATION 4.1 INSTRUCTIONS FOR SAFE USE Safe work with the instrument is only possible after you read thoroughly this manual for use and maintenance and observe precisely the here specified instructions.
  • Page 14 Mixing Station CLEVER II with Stirring Device R1900 / R1800 4. OPERATION 4.1 INSTRUCTIONS FOR SAFE USE MATERIAL Follow the instructions and warnings for the material to be mixed. Material to be mixed can be harmful. Avoid splashing mixed material.
  • Page 15 Mixing Station CLEVER II with Stirring Device R1900 / R1800 4. OPERATION 4.2 STARTING OPERATION AND USE Improper use may damage the device. Observe therefore these instructions: -Use a stirrer up to the specified diameter max Ø 300 mm. -Load the device in such a way that the speed would not drop considerably or that it would stop.
  • Page 16 Mixing Station CLEVER II with Stirring Device R1900 / R1800 4. OPERATION 4.3 ELECTRONIC MOTOR CONTROL 4.4.1 Starting current limiting: The electronically controlled smooth start takes care that the machine starts without jerk. In this manner, the splashing of thin liquid materials is prevent at the same time when switching on the machine.
  • Page 17 Mixing Station CLEVER II with Stirring Device R1900 / R1800 4. OPERATION 4.4 MIXING PROCESS BEFORE MIXING PROCESS Lock the lifting arm firmly on the chassis. Secure the transport rollers using the parking brake. MIXING PROCESS Always pour water into the mix first Always start the device when it is empty or only filled with water Fill the mix through the opening while the machine is running.
  • Page 18 Mixing Station CLEVER II with Stirring Device R1900 / R1800 4. OPERATION 4.5 POUR OUT MIXTURE DISCONNECT THE PLUG BEFORE POURING OUT Stop vacuum Lock the cable on the cover in the cable holder. Stop mixer cleaner operation Release the brake on the transport wheels.
  • Page 19: Storage

    Mixing Station CLEVER II with Stirring Device R1900 / R1800 5 TRANSPORT The device can be moved effortlessly thanks to the four stable transport rollers. To prevent unintentional rolling away, two castors can be secured with a brake. 6 STORAGE The unit should be stored in a dry place where it is protected against freezing.
  • Page 20 111 253 000 / 111 253 500 comply with the EU-Directrive Machinery directive 2006/42/EC EMC directive 2014/30/EU in accordance with with following standards EN ISO 12100:2010 EN 60745-1:2009/A11:2010 EN 55014-1: 2017 EN 55014-2:2015 EN IEC 61000-3-2:2019 EN 61000-3-3:2013/A1/2019 Ehningen, August 2021 Signatory: Olaf Janser, managing director...

This manual is also suitable for:

111 253 000111 253 500