LACO Technologies TITAN VERSA User Manual page 2

Remote i/o module

Advertisement

Installation
Wiring Recommendations
Do not wire to any of the following items: Analog Input pins (CS11 – I2 and
CS31 – I4), RJ12 port, or USB micro port
Do not wire external 24 Vdc power to 24V pin. Use this power for digital
inputs and digital outputs only
Ensure power is off during all installation wiring
Ensure all wire connections are neat and secured properly. Connector can
be removed for easier wiring assembly
General Wiring and Mounting
Connect M12 cable from Remote I/O port to male M12 port on the I/O
module. This cable provides both power (24 VDC fused at 2.0 amps) and
communication bus
Module can be mounted using two main methods
o
o
Wiring Digital Inputs
Wire either +24 or 0 Vdc to COM port per desired digital input type per the
table below
Digital Input Type
PNP, + voltage to input
NPN style, 0 VDC to input
Wire X0 to X7 per desired application inputs.
2
Install provided DIN rail section to underside of TITAN Versa
frame per picture below. Install module and add stop block on end
Install in separate control panel or anywhere as needed
Wiring to Common
Wire 0 VDC to COM and + Voltage to inputs
Wire +24 vdc to common