Digital telemetry system for strain gage applications on rotating shafts (29 pages)
Summary of Contents for KMT TXS
Page 1
76.2 x 50.8 x 20 mm OUTLINE DRAWING Mounting Hole Ø 3.4 mm → txs_manual.pdf latest version of this instruction manual → txs_datasheet.pdf latest version of the TXS datasheet specifications subject to change without notice INSTRUCTION MANUAL 0002 2015 Page 1 (10)
KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com INSTALLATION INSTRUCTION The bottom surface must be securely attached to a baseplate capable of dissipating the power produced by the device. This mounting baseplate must be flat, smooth, and clean.
KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com ISOLATION CONCEPT There are 3 isolated areas: (1) Power Supply Input (2) System Controller & RF Modulator (3) RF Amplifier (connected to case) To prevent damage caused by ESD events overvoltage protection devices are connected between the iso- lated areas.
Page 4
KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com MODULATION ATTENUATORS: There are two attenuators to adapt to different input voltages and to set the desired FM deviation. The input attenuator range is 14 db in steps of 2 dB.
KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com POWER SUPPLY The power supply operating range is 10 Vdc to 36 Vdc. The power supply input is gavanically isolated (floating) against all other parts of the device.
KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com MODULATION INPUT ANALOG SINGLE ENDED The single ended analog modulation mode is the most commonly used input type for video transmitters. MODULATION INPUT ANALOG DIFFERENTIAL...
Page 7
KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com MODULATION INPUT ANALOG SINGLE ENDED WITH OFFSET The single ended analog modulation input with offset allows the direct dc-coupled connection to an analog source with 1.65 V dc offset (this is ½...
Page 8
KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com MODULATION INPUT DIGITAL DIFFERENTIAL (RS422) The RS422 input is suitable for longer distanc- es with twisted-pair cable. This mode guaran- tees the best noise immunity performance.
Need help?
Do you have a question about the TXS and is the answer not in the manual?
Questions and answers