KMT TXS Instruction Manual

S-band telemetry transmitter

Advertisement

Quick Links

KMT - Kraus Messtechnik GmbH
Gewerbering 9
Tel. +49-8024-48737
D-83624 Otterfing
Fax +49-8024-5532
S-BAND TELEMETRY TRANSMITTER
INSTRUCTION MANUAL
OUTLINE DRAWING
latest version of this instruction manual
latest version of the TXS datasheet
TXS
INSTRUCTION MANUAL
www.kmt-telemetry.com
mail
kmt-telemetry.com
@
Mounting Hole
Ø 3.4 mm
→ txs_manual.pdf
→ txs_datasheet.pdf
specifications subject to change without notice
0002 2015
TXS
Page 1 (10)
Dimensions
76.2 x 50.8 x 20 mm

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the TXS and is the answer not in the manual?

Questions and answers

Summary of Contents for KMT TXS

  • Page 1 76.2 x 50.8 x 20 mm OUTLINE DRAWING Mounting Hole Ø 3.4 mm → txs_manual.pdf latest version of this instruction manual → txs_datasheet.pdf latest version of the TXS datasheet specifications subject to change without notice INSTRUCTION MANUAL 0002 2015 Page 1 (10)
  • Page 2: Installation Instruction

    KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com INSTALLATION INSTRUCTION The bottom surface must be securely attached to a baseplate capable of dissipating the power produced by the device. This mounting baseplate must be flat, smooth, and clean.
  • Page 3: Isolation Concept

    KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com ISOLATION CONCEPT There are 3 isolated areas: (1) Power Supply Input (2) System Controller & RF Modulator (3) RF Amplifier (connected to case) To prevent damage caused by ESD events overvoltage protection devices are connected between the iso- lated areas.
  • Page 4 KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com MODULATION ATTENUATORS: There are two attenuators to adapt to different input voltages and to set the desired FM deviation. The input attenuator range is 14 db in steps of 2 dB.
  • Page 5: Power Supply

    KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com POWER SUPPLY The power supply operating range is 10 Vdc to 36 Vdc. The power supply input is gavanically isolated (floating) against all other parts of the device.
  • Page 6: Modulation Input

    KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com MODULATION INPUT ANALOG SINGLE ENDED The single ended analog modulation mode is the most commonly used input type for video transmitters. MODULATION INPUT ANALOG DIFFERENTIAL...
  • Page 7 KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com MODULATION INPUT ANALOG SINGLE ENDED WITH OFFSET The single ended analog modulation input with offset allows the direct dc-coupled connection to an analog source with 1.65 V dc offset (this is ½...
  • Page 8 KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com MODULATION INPUT DIGITAL DIFFERENTIAL (RS422) The RS422 input is suitable for longer distanc- es with twisted-pair cable. This mode guaran- tees the best noise immunity performance.
  • Page 9: Protocol Description

    (1) you'll need a non-inverting TTL-level RS232 connection: TxD(PC) to RxD(TXS)(Pin6) RxD(PC) to TxD(TXS)(Pin13) GND(PC) to GND(TXS)(Pin11) (2) start terminal software 57600,N,8,1 (3) connect power supply TXS will send status screen: RESET; EEPROM_CS=ED85; '?' = HELP MENUE ====[ TXS-S1-P6-Z-X ]========================================================== PIC24FJ64GB004; SW=TXS1; V=001; SN=012345; FREQ=2250.000000; STEP=0.200000;...
  • Page 10 KMT - Kraus Messtechnik GmbH Gewerbering 9 Tel. +49-8024-48737 www.kmt-telemetry.com D-83624 Otterfing Fax +49-8024-5532 mail kmt-telemetry.com COMMANDS: Command Format: pppppp[CR] (pppppp = Parameter, [CR] = ASCII 13) [CR] without parameter = Status; [ESC] = abort current action; -------------------------------------------------------------------------- Change Frequency: 2250F[CR] (2200=2.2GHz;...

Table of Contents