5. TROUBLESHOOTING
CONDITION
Motor fails to run.
Pressure release valve opens to
discharge grease.
Grease gun fails to dispense
grease.
Grease gun continues to lose
prime.
Battery fails to charge.
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product
becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and
dispose of the product and fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 757500
© Jack Sealey Limited
4
3
POSSIBLE CAUSE(S)
Battery needs recharging.
Faulty wiring to motor.
Blocked line.
Blocked bearing.
Blocked grease fitting.
Grease tube is out of grease.
Loss of prime.
Check valve is not functioning.
Air may be trapped in locations
throughout the grease tube assembly
after bulk filling.
Grease tube follower may be
binding.
Charger may not have power.
Battery may be dead.
01284 703534
Original Language Version
CORRECTIVE ACTION
Recharge battery.
Remove battery, disassemble
handle and check wiring for loose
connections.
Check lines, pipe joints and grease
fittings and remove any obstructions.
Check that the tube contains grease.
Repeat priming operation.
Remove check valve, clean and
inspect the valve seat.
Empty grease tube assembly, refill
and repeat priming operation.
Replace grease tube assembly.
Check the mains charger is providing power.