Summary of Contents for Avalon SteriTech GAMBIT
Page 1
Us e r ’s M a nua l Gambit_User_Manual_EN_v1.0 ENGLISH...
Page 2
Gambit App Developed by Avalon SteriTech, Gambit App offers easy control and monitoring features. It enables users to input basic information such as user name, venue, then set the spray time and duration via Bluetooth. By making these operation data...
Table of Contents 1. Introduction 1. Introduction Avalon Steritech, together with Softbank Robotics, aims to develop innovative products and technologies in the fields of cleaning and bio-decontamination. Gambit is one of the innovations where bio-decontamination capability is introduced to 2. Safety Whiz, the world-leading autonomous vacuum robot.
2. Safety 2.1 Symbols used in these instructions 2.2 Fundamental safety warnings Important warnings carry these symbols. These warnings must be strictly observed. WARNING Failure to observe these indications could result in electric shocks, serious injuries, fire or damages to the appliance. This appliance runs on electricity.
Page 5
• Do not use outdoors. • Do not operate the Gambit system in, at or near a place with flammable liquids, gases, or dust. The Gambit system may • To reduce equipment damage risks associated with powerful electromagnetic fields (such as device interference), avoid create sparks that ignite the dust or fumes.
It is designed to attach onto Whiz, the autonomous vacuum cleaning robot developed by SoftBank Robotics. It can also be attached to the Trolley developed by Avalon Steritech for manual operation.
3.1 Part Description Please refer to the diagram below for schematic description of the Gambit system and related accessories: Gambit system power button Main frame Spraying nozzle manual activation button Main frame grommets Solution level indicator LED light Frame bolts (x6)
4. Frame installation CAUTION 4.5 Frame installation instructions • Make sure the procedure is done on a flat and stable surface. Lift the Whiz handle up about 20cm and hold position. • Make sure all electrical components are switched off before performing frame installation on Whiz. Mount main frame over the Whiz.
• Always check the connection before operation. To check the side latch connection: With the Whiz handle down (auto brake engaged), hold the Whiz handle firmly and pull back the Gambit system via its side latches. To check the bottom latch connection: With the Whiz handle down (auto brake engaged), hold the Whiz handle firmly and pull back the Gambit system via its lower frame.
• Do not operate or turn on the Gambit system when charging. • Make sure Gambit system’s solution tank is empty and the drain valve is in the close position before charging the product. • Never apply excessive force on the power charger and power cord. Do not damage the power supply and extension cable 6.4 Instructions to change the GAMBIT fuse...
Gambit system for disinfection purpose. Details regarding the use of PPE could refer to the instructions of • Check to ensure the Gambit system is not charging, and that it is not connected to the power charger during the filling the disinfectant manufacturer which can be found on its labels or website.
• The Gambit system should be switched off and detached from Whiz. • Do not operate the nozzle outside of the permitted maximum angles. • Check to ensure the Gambit system is not charging, and that it is not connected to the power charger during the filling process.
Ensure the Whiz is switched on. Please refer to the Whiz’s user manual for relevant instructions. • The chemical to be used with Gambit has to be authorized by Avalon SteriTech. Oil-based, flammable acid-based or any Couple the Gambit system to Whiz by following instructions described above.
• Wipe or air dry only; do not use dryer, heater or compress air to dry. Remove all loose items on the ground inside the target area to create a visible and safe path for the Whiz and the Gambit system to operate.
Clean off excess water with a dry cotton swab. Step 2: If no LED light is present, follow instructions in Section 6 to recharge the Gambit system and then try to power on the appliance again.
• To lower the chance of false alarm activation, please adjust Gambit’s nozzle spraying angle, routing and run time • The Gambit solution tank can contain up to 2.5 L of solution. Fill up slowly and ensure there is no solid debris build-up in the disinfection protocol.
How often do I need to clean the Gambit system? • Please refer to Section 10 in the User Manual for detailed instructions on how to clean and maintain the Gambit system. • It is recommended to clean the solution tank after each use. Critical steps are as follows: - Step 1: Drain the solution from the Gambit system.
Page 19
Avalon SteriTech Limited w w w . a v a l o n s t e r i t e c h . c o m...