impro technologies IMPROX I16 Installation Manual

Channel input terminal

Advertisement

Quick Links

ImproX I16 16 Channel Input Terminal

SPECIFICATIONS

Working Environment .................
Input Voltage ................................
Power Requirements
Input Voltage 10 V DC
Indicators all OFF ...................
Input Voltage 30 V DC
Indicators all OFF ...................
Input Voltage 10 V DC
Indicators all ON .....................
Input Voltage 30 V DC
Indicators all ON .....................

Digital Inputs

Type .......................................
Protection Range ...................
Figure 1: Options for End-of-line (EOL) Sensing
I
MPRO
INSTALLATION MANUAL
MODEL NUMBER:
X I16
Mounted vertically, with the Cable Entry
Glands at the lower side, the Terminal is
designed to work in an indoor or outdoor
environment similar to IP43.
10 V DC to 30 V DC, polarity sensitive.
Current (mA)
46.30
19.70
80
31.30
16 Dry Contact Digital Inputs.
+80 V to -80 V single pulse,
+35 V to -30 V continuous.
XIT900-0-0-GB-XX
Power (W)
0.47
0.60
0.80
0.95

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the IMPROX I16 and is the answer not in the manual?

Questions and answers

Summary of Contents for impro technologies IMPROX I16

  • Page 1 MODEL NUMBER: XIT900-0-0-GB-XX X I16 MPRO ImproX I16 16 Channel Input Terminal INSTALLATION MANUAL SPECIFICATIONS Working Environment ....Mounted vertically, with the Cable Entry Glands at the lower side, the Terminal is designed to work in an indoor or outdoor environment similar to IP43.
  • Page 2 Find the following when unpacking the Terminal:  An ImproX I16 16 Channel Input Terminal housed in a Black powder-coated Aluminium extruded Cabinet. The Cabinet is sealed at each end with an Aluminium End Plate, secured with 4 Allen Head Screws (M3 x 12 mm).
  • Page 3 Ensure that you use a CE approved Power Supply Unit. Mounting the Terminal CAUTION: Make certain that you mount the ImproX I16 on a vibration-free surface. Select the mounting position of the Terminal, considering accessibility, routing of wires and visibility of the externally visible LEDs.
  • Page 4 ELECTRICAL CONNECTIONS Connecting the Terminal Figure 2 shows a typical electrical connection diagram for the ImproX I16 Terminal. Figure 2: Typical ImproX I16 Electrical Connections XIT300-0-0-GB-09 March 2012 Page 4...
  • Page 5 Fixed Address Label Once the ImproX I16 is installed, sketch a rough site plan. Attach the loose (additional Fixed Address Label packaged with the Terminal) Fixed Address Label in the position of the Terminal on the sketched site plan. When the system installation is complete and all the units are represented on the site plan by their Fixed Address Labels, file the site plan for future reference.
  • Page 6 USER NOTES XIT300-0-0-GB-09 March 2012 Page 6...
  • Page 7 USER NOTES XIT300-0-0-GB-09 March 2012 Page 7...
  • Page 8 This manual is applicable to the ImproX I16 16 Channel Input Terminal, XIT900-0-0-GB-00. (The last two digits of the Impro stock code indicate the issue status of the product). ImproX I16\English Manuals\LATEST ISSUE XIT300-0-0-GB-09 Issue 10 Mar 2012 \ImprXI16-insm-en-10.docx XIT300-0-0-GB-09...

Table of Contents