FOUNTAINS.COM TOP-500EIS-100-12 Quick Setup Manual

Smart weather electronic ignition system (sweis)

Advertisement

Quick Links

Advertisement

Table of Contents
loading

Summary of Contents for FOUNTAINS.COM TOP-500EIS-100-12

  • Page 2: Table Of Contents

    TABLE OF CONTENTS SYSTEM OVERVIEW..........................3 ELECTRONICS............................3 GAS VALVE AND PILOT COMPONENTS ....................3 GAS REQUIREMENTS..........................4 IGNITION CONTROL SPECIFICATIONS ....................4 INSTALLATION............................5 PROPER VENTING..........................8 ACCEPTABLE MEDIA..........................8 OPERATION............................8 MAINTENANCE ............................9 HELPFUL TIPS FOR PROPER OPERATION..................10 12V SYSTEM CLEARANCE FROM COMBUSTIBLES ................14 TROUBLESHOOTING .......................... 15 PARTS LIST &...
  • Page 3: System Overview

    VIEW The Smart Weather Electronic Ignition System utilizes CSA certied components to be added to an outdoor product. Installation must conform with local codes or, in the absence of local codes, with the National Fuel Gas Code, ANSI Z223.1 / NFPA, or International Fuel Gas Code. The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electric Code, ANSI/NFPA 70, if applicable.
  • Page 4: Gas Requirements

    GAS REQUIREMENTS FUEL TYPE GAS PRESSURE REQUIREMENTS Prior to making gas connections, ensure appliance being installed is compatible with the available Pressure Natural Gas Propane Gas gas type. Check the label on the appliance to conrm appliance gas type requirement. Minimum 3.5”...
  • Page 5: Installation

    INSTALLATION STARTUP WARNING: Inspect all components beore installation. A small amount of air will be in the gas supply lines. When I any parts are damaged contact your supplier. DO NOT INSTALL DAMAGED PARTS. rst lighting appliance it will take a short time or air to purge from lines.
  • Page 6 MUST READ! BURNING MEDIA INSTALLTION WARNING: I the inormation in this manual is not ollowed exactly, a re or explosion may result causing property damage, personal injury, or loss o lie. WARNING: Placement o media (glass, lava, stone, etc.) MUST cover pilot assembly.
  • Page 7 GAS CONNECTION Installation or repair should be perormed by a qualied The SWEIS box may now be mounted to the burner or service technician who is locally licensed. The appliance burner & pan combination. Thread sealant must be should be inspected before use and at least annually by used on all pipe thread connections.
  • Page 8: Proper Venting

    PROPER VENTING OPERATION WARNING: HOT - DO NOT TOUCH - MAY RESULT IN WARNING: Venting is required to dissipate heat and SEVERE BURNS any residual uel. Failure to provide proper ventilation - Supervise children in same area as the appliance. could result in overheating and or explosion.
  • Page 9: Maintenance

    MAINTENANCE PRIOR TO EACH USE WARNING: Maintenance should only be perormed Inspect or debris in re eature – remove debris prior by a qualied service technician. The appliance should to use. be inspected beore use and at least annually by a SEMI-ANNUALLY qualied service technician.
  • Page 10: Helpful Tips For Proper Operation

    HELPFUL TIPS FOR PROPER OPERATION Cross ventilation is REQUIRED! A minimum o 1 square inch o ventilation is required or every 25,000 BTUs on each side o the installation. Air ow is your riend! Media (lava rock and glass) minimum o 1/2" and no larger than 2" in diameter. Media must not cover the pilot.
  • Page 11 WWW.THEOUTDOORPLUS.COM PAGE 11 909.460.5579...
  • Page 12 WWW.THEOUTDOORPLUS.COM PAGE 12 909.460.5579...
  • Page 13 WWW.THEOUTDOORPLUS.COM PAGE 13 909.460.5579...
  • Page 14: System Clearance From Combustibles

    MINIMUM 12" CLEARANCE FROM BURNER TO FLOOR WWW.THEOUTDOORPLUS.COM PAGE 14 909.460.5579...
  • Page 15: Troubleshooting

    TROUBLESHOOTING THE SWEIS IS INSTALLED BUT WHEN TURNED ON Electrical Current: NOTHING HAPPENS: I purging the gas line does not solve the problem, The most common cause is an electrical wiring the ignition failure is most likely that the igniter is or power issue.
  • Page 16 WWW.THEOUTDOORPLUS.COM PAGE 16 909.460.5579...
  • Page 17 TROUBLESHOOTING GUIDE SEQUENCE OF FAULT CHECK RESULT ACTION(S) OPERATION Check or 14V at No or low Make sure transormer is powered. I so, replace Transformer voltage transformer. Check wiring or continuity, replace i broken. No Function / No LED Power ON Indication Check or 14V at No or low...
  • Page 18: Parts List & Accessories

    PARTS LIST & ACCESSORIES 24" PILOT IGNITER PILOT IGNITER PILOT IGNITER ASSEMBLY COVER GLOW PLUG TOP-500PIR TOP-PIC TOP-PIGP MINI & STANDARD CAPACITY UNITS TOP-500PIRHC HIGH CAPACITY UNITS BLUETOOTH PILOT TRANSFORMER CONTROLLER ORIFICE(S) TOP-PI23 | #23 ORIFICE OPT-12V TOP-500BLU MINI CAPACITY UNITS TOP-PI30 | #30 ORIFICE STANDARD &...

This manual is also suitable for:

Top-500eis-200-12Top-500eis-300-12