  • Page 1 OPERATOR MANUAL Basil ® 1000 Feeder Bottle Filler (2004-03-04) P122994-772...
  • Page 3: A Word From Steris Corporation

    The Basil 1000 Feeder Bottle Filler is a manifold-type filler designed for filling Indications for Use basket loads of feeder bottles used in the care of laboratory animals.
  • Page 4 THIS PAGE INTENTIONALLY LEFT BLANK 122994-772 Operator Manual Table of Contents...
  • Page 5: Table Of Contents

    TABLE OF CONTENTS Section Title Page A WORD FROM STERIS CORPORATION ........... i 1 LISTING OF SAFETY PRECAUTIONS AND SYMBOLS ..... 1-1 2 UNCRATING/INSTALLATION INSTRUCTIONS ......... 2-1 2.1 Uncrating Instructions ..................... 2-1 2.1.1 Open Crate ....................... 2-1 2.1.2 Move Unit and Remove Skid ................2-1 2.1.3 Prepare Unit for Installation................
  • Page 6 THIS PAGE INTENTIONALLY LEFT BLANK 122994-772 Operator Manual Table of Contents...
  • Page 7: Listing Of Safety Precautions And Symbols

    Regularly scheduled preventive maintenance, in addition to the faithful performance of the minor maintenance described within this manual, is required for safe and reliable operation of this equipment. Contact STERIS to schedule preventive maintenance. When moving the unit, use a forklift.
  • Page 8 CAUTION – POSSIBLE EQUIPMENT DAMAGE: Use non-abrasive cleaners when cleaning unit. Follow directions on containers and rub in a back and-forth motion (in same direction as surface grain). Abrasive cleaners will damage stainless steel. Cleaners rubbed in a circular motion or applied with a wire brush or steel wool can be harmful to stainless steel. When using Pry Cream, rub in a back-and-forth motion (in same direction as surface grain).
  • Page 9: Uncrating/Installation Instructions

    If unit has been tipped, notify STERIS and arrange to have a service technician review the equipment and determine if unit was dam- aged.
  • Page 10 Tip Indicator Skid Figure 2-1. Crate 122994-772 Operator Manual Uncrating/Installation Instructions...
  • Page 11: Installation Instructions

    1000 Feeder Bottle Filler. b. Utility service lines: • Disconnect switch (not by STERIS) must be installed in the electric supply line near the bottle filler (see Figure 2-2). Disconnect switch must be capable of being locked in the OFF position only.
  • Page 12: Install Anchorage System

    2.2.3 Install Anchorage Once unit is level, install anchorage system as follows: System 1. Mark floor holes position. (If anchoring brackets do not touch the floor use shims.) 2. Using a forklift, move the unit to clear area. 3. Drill holes in floor. 4.
  • Page 13: Installation Checklist

    After installing the unit, complete the following checklist to assure complete 2.3 Installation and correct installation. Contact STERIS to schedule a demonstration of proper equipment operation. Checklist Shutoff valve (not provided by STERIS), for maintenance purposes, is installed on the water line and is in compliance with local codes.
  • Page 14 THIS PAGE INTENTIONALLY LEFT BLANK 122994-772 Operator Manual Uncrating/Installation Instructions...
  • Page 15: Component Identification

    • Timer - Set desired filling time to automatically fill the bottles. Water Line Connection Electrical Control Panel Filler Header with Jets Shutoff Valve Splash Hood Basket Stop Adjustable Feet Figure 3-1. Basil 1000 Feeder Bottle Filler Component Identification Operator Manual 122994-772...
  • Page 16: Accessories

    Stainless-steel manifold headers can accommodate different bottle/basket 3.3 Accessories sizes. Each manifold has individual stainless-steel jets for each bottle. It connects to Bottle Filler by a quick-disconnect clamp. • 5 x 5 Filler Header (Figure 3-2): 3.3.1 Filler Header Dimensions: 14-3/4 x 16-3/4 x 2-3/4" (370 x 430 x 70 mm) Coverage: 25 bottles Figure 3-2.
  • Page 17: Bottle Baskets

    3.3.2 Bottle Baskets Stainless-steel bottle baskets can accommodate different bottle sizes. Refer to Figures 3-4 through 3-7 Figure 3-4. 5 x 5 Bottle Basket Figure 3-5. 5 x 5 Bottle Basket (16 oz bottles [454 mL]) (8 oz bottles [227 mL]) Figure 3-6.
  • Page 18 THIS PAGE INTENTIONALLY LEFT BLANK 122994-772 Operator Manual Component Identification...
  • Page 19: Operating Instructions

    OPERATING INSTRUCTIONS NOTE: Refer to Section 3 for location of components. 4.1 Before Operating Check that unit shutoff valve (water) is open. Equipment See Figure 4-1 4.2 Filling the 1. Place a basket of clean bottles under the filler header manifold up to the Bottles basket stops.
  • Page 20 THIS PAGE INTENTIONALLY LEFT BLANK 122994-772 Operator Manual Operating Instructions...
  • Page 21: Routine Maintenance

    MENT DAMAGE HAZARD: Regularly scheduled pre- NOTE: Never permit unqualified persons to service the bottle filler. ventive maintenance, in STERIS recommends use of the following cleaning products (see Table 7-2 for addition to the faithful per- ordering information): formance of the minor •...
  • Page 22: Daily Cleaning

    At the end of each day, visually inspect each filler manifold jet by looking into 5.2 Daily Cleaning the opening of each jet or by observing the spray pattern of each jet during operation. If a jet appears to be plugged or partially blocked, proceed as follows: CAUTION –...
  • Page 23: Troubleshooting

    If you are unable to correct the problem by using the Troubleshooting Table, MENT DAMAGE HAZARD: or if a problem occurs that is not described in the table, please contact STERIS. Only fully qualified service A factory-trained technician will promptly place your bottle filler in proper personnel should as- working order.
  • Page 24 THIS PAGE INTENTIONALLY LEFT BLANK 122994-772 Operator Manual Troubleshooting...
  • Page 25: Replacement Parts And Products

    Table 7-2. 2. Include the model and serial numbers of your bottle filler on your order. 3. Send your order directly to the STERIS sales and service center serving your area. Contact STERIS if you need parts that are not listed below.
  • Page 26 THIS PAGE INTENTIONALLY LEFT BLANK 122994-772 Operator Manual Replacement Parts and Products...
  • Page 27 Contact Information: Sales and Service: Technical Assistance: STERIS Corporation STERIS Engineering Services 5960 Heisley Road 2424 West 23rd Street Mentor, Ohio 44060 Erie, PA 16506 Tel.: 440 354 2600 Tel.: 814 452 3100 Fax : 440 639 8199 Fax: 814 870 8400...