Compressed air filters

Advertisement

Quick Links

Quincy
Compressed air filters
QAF, QCF, QMF, QPF, QWS 6-1500
Instruction book

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the QAF 6-1500 and is the answer not in the manual?

Questions and answers

Summary of Contents for Quincy Compressor QAF 6-1500

  • Page 1 Quincy Compressed air filters QAF, QCF, QMF, QPF, QWS 6-1500 Instruction book...
  • Page 3 Quincy Compressed air filters QAF, QCF, QMF, QPF, QWS 6-1500 Instruction book Original instructions Copyright notice Any unauthorized use or copying of the contents or any part thereof is prohibited. This applies in particular to trademarks, model denominations, part numbers and drawings.
  • Page 4: Table Of Contents

    Instruction book Table of contents Safety precautions......................4 ........................... 4 AFETY ICONS ................... 4 AFETY PRECAUTIONS DURING INSTALLATION ....................5 AFETY PRECAUTIONS DURING OPERATION ................5 AFETY PRECAUTIONS DURING MAINTENANCE OR REPAIR ....................... 6 ISPOSAL OF USED MATERIAL Description........................7 ........................7 ENERAL DESCRIPTION ............................
  • Page 5 Instruction book ........................25 IMENSIONS AND WEIGHT 2920 7195 00...
  • Page 6: Safety Precautions

    Instruction book Safety precautions Safety icons Explanation Danger to life Warning Important note Safety precautions during installation 1. Install the equipment where the ambient air is cool and as clean as possible. Consult section Reference conditions and limitations. 2. During installation or any other intervention on the equipment or one of the connected machines, the machines must be stopped, de-energized and the isolating switch opened and locked before any maintenance or repair.
  • Page 7: Safety Precautions During Operation

    Instruction book Safety precautions during operation All responsibility for any damage or injury resulting from neglecting these precautions, or non-observance of the normal caution and care required for installation, operation, maintenance and repair, even if not expressly stated, will be disclaimed by the manufacturer.
  • Page 8: Disposal Of Used Material

    Instruction book 7. Never use a light source with open flame for inspecting the interior of the device. 8. All regulating and safety devices shall be maintained with due care to ensure that they function properly. They may not be put out of action. 9.
  • Page 9: Description

    Instruction book Description General description Quincy filters are available in a number of grades and sizes. (P, M, C, A, sizes 1–18) (WS, sizes 1–13) Naming of the filters: QPF (flow)(connection)(-/indicator/gauge) Example: QPF 280 (G1 1/4) G is a Quincy P grade Filter with a nominal flow of 280 scfm, a N1 1/4 connection with a pressure gauge.
  • Page 10 Instruction book Grade Description Maximum air Air flow Differential pressure Drain inlet pressure Indicator Gauge • Coales 16 bar From inside to • Size 1– • Size 1– Automatic cing outside 2: Not 2: Not drain filters available available general •...
  • Page 11 Instruction book Grade Description Maximum air Air flow Differential pressure Drain inlet pressure Indicator Gauge • Particul 20.7 bar From outside • Size 1– • Size 1– Manual drain to inside 2: Not 2: Not filters available available for dust protecti •...
  • Page 12 Instruction book Grade Description Maximum air Air flow Differential pressure Drain inlet pressure Indicator Gauge • Oil 20.7 bar From inside to Manual drain vapour outside odour remova l filter • Air flows through activate carbon, which absorb s oil vapour s and odours...
  • Page 13: Options

    Instruction book Drains The automatic mechanical float drain valve will discharge liquid from the filter bowl when it reaches a fixed level in the bowl. Automatic float drain The manual drain can be used to manually discharge dust or liquid from the filter bowl. Manual drain valve Options Filter connection kit...
  • Page 14 Instruction book Always observe the correct air flow direction. Install a G filter upstream of a C grade filter. An arrow indicating the air flow direction is shown on the filter head or differential pressure indicator. Wall mounting kit For wall mounting, a special set is available as option. Fit the mounting brackets with bolts, washers and nuts to a solid frame within easy reach, leaving sufficient space for maintenance and service.
  • Page 15 Instruction book Electronic drain The electronic drain is a zero loss, electronically operated drain valve, specially designed to drain oil condensate. A sensor senses the condensate level. If this level exceeds a preset value, the drain waits for a fixed programmed time, then a solenoid valve is activated and the condensate is discharged.
  • Page 16: Installation

    Instruction book Installation General remarks When installing the filter, keep in mind the following: • Be sure that the piping is internally clean, especially downstream of the filter. • Select the filter grade in line with the application requirements. When selecting the filter size, take care that the maximum flow capacity is not exceeded to make sure that filtration performance and filter lifetime are guaranteed.
  • Page 17: Specific Remarks

    Instruction book • Open and close isolating valves slowly, as a sudden pressure rise or pressure drop can cause irreversible damage to the filter element. Specific remarks P filter The P grade filter can be used in installations where high oil or dust loads are expected. In critical applications it is recommended to install a grade G (for oil) or a grade S (for dust) or a grade C (for oil) or a grade D (for dust) filter downstream the P filter to improve the air quality.
  • Page 18: Iso 8573-1

    Instruction book S filter and D filter When the S and D filters are used with an adsorption type air dryer, install the filter downstream of the dryer. V filter To protect the activated carbon element, a V filter must always be preceded by a G and C filter. The filter should be mounted as close as possible to the point of use of the air.
  • Page 19 Instruction book A few examples are given in the image below. General purpose protection With grade P filter: air quality to ISO 8573-1: class 4:-:3 With grade G filter: air quality to ISO 8573-1: class 3:-:3 High quality air with reduced dew point (air quality to ISO 8573-1: class 1:4:1) General purpose protection and reduced oil concentration (air quality to ISO 8573-1: class 1:-:2)
  • Page 20: Iso 12500

    Instruction book Components shown in above image Item Description Item Description Compressor with after cooler D filter G filter (or P filter in configuration A) Refrigerant dryer C filter Desiccant dryer V filter (for critical applications) Compressor with integrated dryer S filter VT filter Compressed air may come into direct or indirect contact with food.
  • Page 21: Maintenance

    Instruction book Maintenance Maintenance When maintaining the filter, keep in mind the following: • On filters with manual drain valve, open the latter at regular intervals to evacuate collected dust or liquid. • In case an automatic drain valve or a solenoid timer drain is installed, manual draining can be carried out by opening the valve counterclockwise to release collected condensate.
  • Page 22: Service Intervals

    Instruction book 6. Remove the drain valve by unscrewing the retaining nut underneath the bowl. 7. Remove the O-ring from the filter head and clean the o-ring groove. Position a new O-ring in the filter head. 8. Reinstall the drain valve in the bowl using the retaining nut (tightening torque 3 Nm). 9.
  • Page 23 Instruction book Note that the indicator or gauge will not move into the red area but will stay yellow or orange during operation. The filter elements of dust filters (S, D) should be replaced after 8000 running hours or after 12 months (whichever comes first).
  • Page 24: Technical Data

    Instruction book Technical data Reference conditions Air inlet pressure 7 bar(e) 102 psig Air inlet temperature 20˚C 68 ˚F Ambient temperature 20˚C 68 ˚F Principal data Maximum compressed air inlet pressure Coalescing filters Coalescing filters (P-G-C) + WS: 16 (P-G-C) + WS: bar(e) 232 psig Minimum compressed air inlet pressure...
  • Page 25 Instruction book G filter and C filter Challenge/inlet oil concentration mg/m Initial pressure drop over filter when dry mbar Initial pressure drop over filter when saturated mbar Oil carry-over (aerosol) 0.01 mg/m Total mass efficiency >99.25 >99.9 Remark Typical Typical installati installati on (1)
  • Page 26: Rated Flow At Reference Conditions

    Instruction book WS filter Total bulk water removal efficiency Typical pressure loss at rated flow mbar Rated flow at reference conditions For P, G, C, S, D and V filters Size m³/h scfm l/min 11.7 23.6 1416 33.1 1986 2400 49.4 2964 58.9...
  • Page 27: Correction Factors

    Instruction book Size m³/h scfm l/min 151.4 9084 330.3 1189 19818 401.1 1444 24066 708.3 2550 1500 42498 Correction factors When the actual working pressure differs from the reference pressure, multiply the nominal capacity of the filter with the corresponding correction factor to obtain the correct capacity. Operating pressure bar(e)
  • Page 28 Instruction book Size Filter Filter Filter Manual Automatic Service dimension A dimension B dimension C Drain length Drain length distance E (mm) (mm) (mm) D (mm) D (mm) (mm) 1005 Size Filter Filter Filter Manual Automatic Service dimension A dimension B dimension C Drain length Drain length...
  • Page 29 Instruction book Size Filter volume, Weight (kg) Shipping Shipping width Shipping head+bowl (l) length (mm) (mm) height (mm) 0.25 1020 10.5 1175 10.5 1175 11.5 1175 12.5 1300 Size Filter volume, Weight (lb) Shipping Shipping width Shipping head+bowl length (in) (in) height (in) (gal)
  • Page 30 Instruction book For WS filters Size Filter Filter Filter Automatic Service dimension A dimension B dimension C Drain length D distance E (mm) (mm) (mm) (mm) (mm) Size Filter Filter Filter Automatic Service dimension A dimension B dimension C Drain length D distance E (in) (in) (in)
  • Page 31 Instruction book Size Filter volume, Weight (kg) Shipping Shipping width Shipping head+bowl (l) length (mm) (mm) height (mm) 0.25 0.25 Size Filter volume, Weight (lb) Shipping Shipping width Shipping head+bowl length (in) (in) height (in) (gal) 0.03 0.55 10.24 2.56 2.56 0.03 0.55...
  • Page 32 Instruction book Size Filter volume, Weight (lb) Shipping Shipping width Shipping head+bowl length (in) (in) height (in) (gal) 1.19 17.64 28.74 9.25 8.66 2920 7195 00...
  • Page 34 Performance You Demand. Reliability You Trust. www.quincycompressor.com...

This manual is also suitable for:

Qcf 6-1500Qmf 6-1500Qpf 6-1500Qws 6-1500