Introduction
The ME-PT1 (Pigtail one-wire) adapter is designed to be connected to the
Magnum Energy Auto Generator Start (AGS) controller to allow the connected
generator to be started when an external +12 volt DC supply is applied. This
is useful in applications where there is a requirement to conveniently and au-
tomatically turn the generator on/off externally through a manually controlled
switch or from an automatically controlled switching device.
This adapter provides one pigtail wire and when +12 volts is supplied to this
pigtail wire, causes the Magnum Auto Generator Start controller to start and
run the connected generator.
Info: The high temperature start feature on the ME-AGS is not avail-
able when using the ME-PT1. However, the low battery voltage start
feature is still available.
Installation/Setup - ME-AGS-N (Network Version)
The following pertains to the ME-PT1 when connected to the ME-AGS.
Info: Refer to the ME-AGS-N Operators Manual (64-0005) for installa-
tion, setup and operation of the ME-AGS-N; and the ME-RC Operation
Manual (64-0003) on information to select/adjust settings.
Installation
Refer to fi gure 2 for the following steps to install the ME-PT1:
1. Connect the red wire on the adapter to a +12 volt DC external switching
device (i.e. switch).
2. Plug the ME-PT1 adapter into the REMOTE (purple) port on the ME-AGS-N.
Info: The remote temperature sensor that comes with the ME-AGS-N
and is normally plugged into the REMOTE (purple) port is not used
when the ME-PT1 is connected.
Setup
When using the ME-PT1 with the ME-AGS-N, confi gure the ME-RC to allow the
ME-AGS-N to accept the external input from the ME-PT1 (see fi gure 1):
1. Press the AGS button and rotate the SELECT knob to the '04 Start Temp F'
menu. 2. Press the SELECT knob and rotate the SELECT knob to choose the
'Start=Ext Input' setting. 3. Press the SELECT knob to save this setting.
AGS
press
Status ...
StartTemp = Off
Figure 1, Selecting the Start=Ext Input Setting
Part Number: 64-0025
rotate to
press to select
Status...
Status ...
Start=Ext Input
StartTemp = 65F
Magnum Energy Inc.
1111 80th Street SW, Suite 250
Everett, WA, USA 98203
www.magnumenergy.com
rotate to:
Start=
Ext In p u t
Status ...
.......
StartTemp = 85F
press to save
Status ...
StartTemp = 90F
1

Advertisement

loading

Summary of Contents for Magnum Energy ME-PT1

  • Page 1 ME-PT1 is connected. Setup When using the ME-PT1 with the ME-AGS-N, confi gure the ME-RC to allow the ME-AGS-N to accept the external input from the ME-PT1 (see fi gure 1): 1. Press the AGS button and rotate the SELECT knob to the ‘04 Start Temp F’...
  • Page 2 Box w hen gen needs to start. C o leman A ir C o n d itio n er Z o n e C o n tro l B o x Figure 2, ME-PT1 to ME-AGS-N Installation ©2008 Magnum Energy Inc.
  • Page 3 1. Plug a 6-conductor phone splitter into the REMOTE (purple) port on the ME-AGS-S controller. 2. Plug the ME-PT1 pigtail into one port of the phone splitter and plug the remote switch using its communications cable into the other port of the phone splitter.
  • Page 4 Box w hen gen needs to start. C o leman A ir C o n d itio n er Z o n e C o n tro l B o x Figure 5, ME-PT1 to ME-AGS-S Installation ©2008 Magnum Energy Inc.