AP Bio-Dri II Instructions

Air inlet door

Advertisement

1004 East Illinois Street • Assumption, IL 62510 • 1-217-226-4421

Inlet Door Assembly Instructions

1. Construct frame and rough opening for inlet door. Ensure that the inside surface of both rough
openings is 3'' from the inside corner of the door hinge according to detail.
2. Assemble two (2) hinges (B) to top and bottom of door (A), using bolt (C) and nylock nut (D).
With two (2) persons, lift door and hinges over rough opening on inside of air mixing chamber and
center vertically. Ensure that the corner of the hinges are against the inside corner of the framing as
shown in
Figure
1. Secure door and hinges to frame with four (4) lag screws (E) through each of the
four (4) hinges (B) and into the framing.
Inside corner for
door hinge
Ref #
Part #
A
AP-5292
Inlet Door 4' x 6' Black
B
AP-5291
Inlet Door Pivot Frame Support - Hinge
C
S-7935
Bolt, HHCS 1/2''-13 x 1'' ZN Grade 5
3. According to
Figure 2 on Page 2.
to hinge. Ensure it is centered vertically within the rough opening and secure with four (4) lag screws
(E) into the framing. Also vertically centered on opposite side of rough opening, install short straight
brace (H) and secure with four (4) lag screws (E) into the framing.
4. Install the tubular brace (J) to the lower hole on the outer face of the short straight brace (H). Rotate
the tubular brace downward to about 45° until the bottom end fits inside the rough opening. Secure
with a lag screw (E) to the framing.
5. Install the bottom anchor plate (I) between diagonal and straight braces, using four (4) bolts (L) and
four (4) nylock nuts (M).
6. Lay linear actuator (F) on top of bottom anchor plate (I) and connect rod end of actuator to pivot hole
in door. Secure rod connection with bolt (N) and nylock nut (D).
7. Lay top anchor plate (I) on top of linear actuator (F), diagonal brace (G) and straight brace (H),
then install long pivot bolt (K) through top anchor plate, actuator and bottom anchor plate. Secure
with nylock nut (D). Align top anchor plate mounting holes with diagonal brace and straight brace.
Secure with four (4) bolts (L) and four (4) nylock nuts (M).
Date: 05-06-16
V1.0
Printed in the U.S.A.
Copyright © 2016 by The GSI Group, LLC
www.gsiag.com
Figure 1
Description
Qty
Install long diagonal brace (G) to inside of rough opening closest
Bio-Dri II™ Air Inlet Door
Assembly Instructions
Ref #
Part #
1
D
S-8260
Nylock Nut 1/2''-13 ZN Grade 5
4
E
S-7308
Lag Screw 3/8'' x 2'' HH ZN
2
PNEG-1984
Instructions
(See Figure 1.)
Description
Qty
2
16
PNEG-1984
Page 1 of 4
CN-324780

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Bio-Dri II and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for AP Bio-Dri II

  • Page 1 Instructions Bio-Dri II™ Air Inlet Door Assembly Instructions 1004 East Illinois Street • Assumption, IL 62510 • 1-217-226-4421 Inlet Door Assembly Instructions 1. Construct frame and rough opening for inlet door. Ensure that the inside surface of both rough openings is 3'' from the inside corner of the door hinge according to detail.
  • Page 2 Bio-Dri II™ Air Inlet Door Assembly Instructions Inlet Door Assembly Instructions (Continued) Figure 2 Ref # Part # Description S-8260 Nylock Nut 1/2''-13 ZN Grade 5 S-7308 Lag Screw 3/8'' x 2'' HH ZN AP-5300 Linear Actuator Assembly for Inlet Door...
  • Page 3 Re-Cycle position in order to keep birds and debris from entering the air mixing chamber. When the Bio-Dri II™ is in Pre-Bake mode, Bake mode or Post Bake mode, the inlet door should be in Re-Cycle position in order to allow the hot air to Re-Cycle through the system. The only time the inlet door should be in Purge position, is during the 8 minute purge time at the end of the cycle, in order to clear out deadly gas fumes and quickly cool the room down, prior to safe entry.
  • Page 4 Bio-Dri II™ Air Inlet Door Assembly Instructions Inlet Door Adjustment Instructions (Continued) Figure 3 Ref # Part # Description TD-101463 Limit Switch AP-5388 Bracket, Limit Switch Mounting S-10171 U-Bolt, 5/16''-18 for 1-1/4" Pipe ZN AP-5389 Actuator Bracket 326-1047-9 U-Bolt, 5/16''-18 x 1-3/8'' x 2-3/1''...

Table of Contents