Devolo MT:2653
Quick Start
C
This
remote
control
the normal
operation for
and management mode for setup. Pushing all
four buttons for 1 sec. turns the device into
management mode (indicated by slow blinking
green LED). Management mode time-out is 10
sec.
In factory default mode pushing one of the four
buttons for 1 sec will start different inclusion
modes:
Button 1: Include (Add) KFOB as sec.
•
controller
Button
2:
Include
•
secondary controller - non secure
Button 3: Include (add) new device into
•
KFOBS network
Button 4: Include (add) new device into
•
KFOBS network - non secure
The process for button 1 and 2 are indicated
with fast red/green blinking, the process for
button 3 and 4 show a fast green blinking. Every
button
push
stops
inclusion only
works
factory default. Once one device is included or
the fob is included as secondary controller
further inclusion and exclusion operation require
to turn the device into management mode. In
management mode
Button 1: Include or Exclude the device as
•
secondary controller
has
two
modes:
daily
(add)
KFOB
the
process.
This
when
device
is
Button 2: Issue Wakeup Notification and
•
send out Node Information Frame
Button 3 followed by short click of button
•
1: Start Secure Inclusion
Button 3 followed by short click of button
•
2: Start Unsecure Inclusion
Button 3 followed by short click of button
•
3: Start Exclusion
use
Button 3 followed by short click of button
•
4: Start Primary Handover
Attention: For convenience reason some special
short cut apply IF and only IF the KFOB is the
primary controller of the network: The first
device included into a button group will
define the commands sent out by this group
regardless
a door lock the button group will turn into door
lock control (value=7). For dimmers and motor
controls the value changes into Multilevel Switch
as
Control (value=1). All other devices will turn the
button group into Basic control (value=2). All
configuration values can be changed if needed.
When KFOB is primary controller the very first
device included will be automatically put
into button group A and the command set will
change according to the rules just mentioned. All
other devices need ot be put in button groups
manually.
Product description
The Secure Key Fob Controller is a 4 button Z-
Wave device capable to act both as primary or
secondary
control
other
switches, dimmer and even door locks
directly. Various options - configurable by Z-
Wave configuration commands - define the
actions and the commands used for this control.
It is possible to use two sets of buttons (one of
fast
on/open/up and one for off/closed/down) or 4
in
single buttons to control 4 different groups of
devices.
The controller also allows triggering scenes in
a central controller. Again different modes can
be
configured
implementations of scenes in different central
controllers in the market.
of
the
default
controller.
The
four
Z-Wave
devices
to
adapt
to
value
of
the
buttons can
such
as
the
various
Need help?
Do you have a question about the MT:2653 and is the answer not in the manual?
Questions and answers