Genesis CD–2G, CD–5G, & CD–7G Installation & Operations Manual SECTION 1 General Information SECTION 2 Installation 1A. Description 2A. Location The Genesis ™ Corona Discharge series ozone The CD-2G, CD–5G, & CD–7G are designed for wall mounting. See Figure 1. Mount generator...
Genesis CD–2G, CD–5G, & CD–7G Installation & Operations Manual 3. Install the four mounting bolts through the Wall 2. The injector assembly is also equipped with a Mounting Brackets and into the anchors. compression fitting. Connect the other end of ozone tubing to the injector suction port as 2B-2.
Genesis CD–2G, CD–5G, & CD–7G Installation & Operations Manual SECTION 3 Operation WARNING: Pool pump flow must not be shut- down when the ozone generator is operating. Doing so may cause water to back flow into the 3A. Initial System Start-Up system and damage the generator module.
Genesis CD–2G, CD–5G, & CD–7G Installation & Operations Manual DEL OZONE COMMERCIAL PRODUCT LIMITED TWO YEAR WARRANTY The limited warranty set forth below applies to products manufactured by DEL OZONE – 3580 Sueldo Street, San Luis Obispo, California 93401, and sold by DEL OZONE or its authorized dealers. This limited warranty is given only to the first retail purchaser of such products and is not transferable to any subsequent owners or purchasers of such products.
Page 10
Genesis CD–2G, CD–5G, & CD–7G Installation & Operations Manual OZONE Material Safety Data Sheet SECTION I: MATERIAL IDENTIFICATION IDENTITY: OZONE (Gaseous) ISSUED: February, 1992 FORMULA: O REVISED: May 12, 2014 Description (origin/uses): Occurs in atmosphere from UV light action on oxygen at high altitude. Commercially obtained by passing air between electrodes carrying a high voltage alternating current.
Page 11
Genesis CD–2G, CD–5G, & CD–7G Installation & Operations Manual Chemical Incompatibilities: Ozone is chemically incompatible with all oxidizable materials, both organic and inorganic. Conditions to Avoid: Ozone is unstable at room temperatures and spontaneously decomposes to oxygen gas. Avoid ignition sources such as heat, sparks, and open flame.
Page 12
Genesis CD–2G, CD–5G, & CD–7G Installation & Operations Manual Page 1 of 3 Material Safety Data Sheet NFPA 704 Designation Hazard Rating This MSDS complies with OSHA’s Hazardous Communication Standard 29 CFR 1910.1200 and OSHA form 174. 4 = Extreme...
Page 13
Genesis CD–2G, CD–5G, & CD–7G Installation & Operations Manual Page 2 of 3 Material Safety Data Sheet Cont. Product Name AQUEOUS OZONE SOLUTION IV HEALTH HAZARD DATA Threshold Limit Value NOT DETERMINED Route of Exposure Inhalation Ingestion Skin Not Hazardous Eye Contact Hazard Exposure may cause mild eye irritation, but is not expected.
Page 14
Genesis CD–2G, CD–5G, & CD–7G Installation & Operations Manual Page 3 of 3 Material Safety Data Sheet Cont. Product Name AQUEOUS OZONE SOLUTION VII SPILL OR LEAK PROCEDURES Steps To Be Taken If Material Is Released NONE Or Spilled Waste Disposal...
Page 16
3580 Sueldo Street, San Luis Obispo, CA 93401 | 800.676.1335 | o3info@delozone.com | www.delozone.com EPA Estab. No. 071472-CA-001...
Page 17
Manual Addendum for Ozone Generator Models: CD-2G-PRO, CD-2G-50-PRO CD-5G-PRO, CD-5G-50-PRO CD-7G-PRO, CD-7G-50-PRO NOTE: KEEP THIS SHEET & ATTACH TO INSTALLATION & OPERATION MANUAL (4-1391-01). The –PRO models are custom variations of the standard ozone generators. These versions have a 4-20mA control assembly, variable high voltage power supply, and revised wiring.
Need help?
Do you have a question about the DEL ozone CD-2G and is the answer not in the manual?
Questions and answers