2 General description The FMC700 is an adapter that recreates an FMC site from the KC705 LPC and HPC FMC sites in order to offer a HPC FMC site as close as possible to ANSI/VITA 57.1. This adapter connects to the KC705 via both FMC connectors and has a FMC standard HPC connector on the other side.
LA[00:21] (Bank 12&13) LA[22:33] (Bank 13) CLK[0:1] (Bank 12&13) Figure 4: User Defined Signal Routing 5.1.1 HPC HA Signal All 24 differential HA signals from KC705 HPC are connected to the FMC through the FMC700. Oct 2012 www.abaco.com - 7 -...
5.1.2 HPC LA Signal All 34 differential LA signals from KC705 HPC are connected to the FMC through the FMC700. 5.1.3 LPC LA Signal 22 differential LA signals (LA00 to LA21) from KC705 LPC are connected to the FMC through the FMC700 and remaining LA signals (LA22 to LA33) are discarded.
FMC700. KC705 provides only 4 differential GTX signals (DP [0:3]). 5.2.2 LPC GTX Signal Differential GTX signals from KC705 LPC are routed to the FMC through the FMC700. These DP signals are connected to bank 117 while HPC GTX clock signals are connected to bank 118.
6 Power All pin assignments are summarized on the Appendix A. 6.1 HPC Power Signal All power signals from KC705 HPC are fully connected to the FMC through the FMC700. 6.2 LPC Power Signal Two VCC12_P (12V ) power signals are routed to the fan connector. VADJ, 3P3V and 3P3VAUX power signals are not connected to HPC power signals.
FMC700 User Manual r1.0 8.2 Cooling 8.2.1 Convection cooling The air flow provided by the fan installed on the adapter will dissipate the heat generated by the on board components from FMC. 9 Safety This module presents no hazard to the user.
FMC700 User Manual r1.0 Appendix A FMC700 Pinout AV57.1 shows the signal definitions of the AV57.1 Standard and KC705 shows the net names of the signals connected to KC705 Yellow highlights indicate LPC signals from KC705, all other signals are from the KC705 HPC connector.