Download Print this page

Advertisement

Quick Links

1.
1.1.
1.2.
1.3.
1.4.
1.5.
1.6.
MANUAL GIGASYNC V2
GIGASYNC
Base Unit
how it looks
block diagram
voltage range
connectors scheme
ethernet pinout, sync-in and sync-out
LED legend
OPT functions
Cartridges
how they look
comparative table
LED legend
9.KEY
Installation
Software update
WEB Interface
Command Line Interface
pag. 2
pag. 2
pag. 2
pag. 3
pag. 3
pag. 4
pag. 4
pag. 4
pag. 4
pag. 5
pag. 5
pag. 6
pag. 6
pag. 6
pag. 7
pag. 8
pag. 9
pag. 13
VER. 2 REV. 1
1

Advertisement

loading

Summary of Contents for 9dot GIGASYNC V2

  • Page 1 5 comparative table pag. 6 LED legend pag. 6 9.KEY pag. 6 1.3. Installation pag. 7 1.4. Software update pag. 8 1.5. WEB Interface pag. 9 1.6. Command Line Interface pag. 13 MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 2 GPS antenna. For a correct operation of the surge protectors, it is necessary to connect the ground terminal GND. MAIN POWER ETHERNET PORT GPS ANTENNA CONNECTOR POWER PRESENCE LEDs CARTRIDGE REDUNDANT POWER CONNECTORS SYNC OUT / SYNC IN MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 3 The two CPUs are powered by an isolated converter. In this way it is guaranteed maximum immunity against electrical faults on the supply lines of the cartridges. Functions available only on PoE-CS Cartridge. ** Functions available only on PoE and PoE-CS Cartridge. MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 4 WiFi on / off ALARM LED starts flashing after switching on or off WiFi interface about 5 seconds off RESET after about 30 seconds turns the configuration reset and restore the factory settings LED STATUS MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 5 TVS and GDT surge arresters on each line. GS-G-PoE | GS-G-PoE-CS LAN Ports FRONT VIEW PoE Ports STATUS LEDs SIDE VIEW BACK VIEW KEY SLOTS MAIN CONNECTOR GS-G-TER Terminals FRONT VIEW STATUS LEDs SIDE VIEW BACK VIEW MAIN CONNECTOR MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 6 The cartridges can be inserted and removed from the Base Unit even if the system is powered and operational. It is preferable to connect the devices to be powered after the insertion of the cartridge to ensure proper calibration of the readings. MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 7: Installation

    CARTRIDGE SLOTS No fixing screws for the cartridges are required, the connector provides sufficient strength to prevent that they do not inadvertently fall. To remove the cartridge pull hard the handle. MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 8: Software Update

    GigaSync automatically validate the update installation package. During the update procedure, GigaSync continues to power the devices connected to it and continues to inject the sync pulse. When the red LED stops flashing, the software update is complete. MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 9 The load applied to each port is indicated by a color so as to make it readily apparent which are the devices with greater consumption and closer to the maximum load limit. GREEN, <50% YELLOW, 50% - 75% RED,> 75% MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 10 It is possible also to enable the Sync Cascade and feed the Sync-IN port for the direct supply of a uGPS. LOG tab displays the events. MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 11 10 seconds on the port. SYNC only in PoE cartridges, enables desired type synchronization. RENAME It allows to edit the description of the port to identify it in a simple way. MANUAL GIGASYNC V2 VER. 2 REV. 1...
  • Page 12 It is also possible to check the status of integrity of the With the TAB key you can view the complete menu and update packages and perform the update. typing the command. MANUAL GIGASYNC V2 VER. 2 REV. 1...