Safety Instructions; Technical Data - Efco KPX Operating Instructions Manual

Rewind cable reel ex
Table of Contents

Advertisement

Available languages

Available languages

KPX
1. General
The product
The EX rewind cable reel KPX with earthing clamp is used for temporary equipotential
bonding connections.
Intended use
The rewind cable reel KPX complies with ATEX device class II in categories 2G and 2D.
It is therefore intended for use in EX zones 1 and 21 or 2 and 22.
Content of delivery
Rewind cable reel in a robust plastic housing with equipotential bonding conductor and
a grounding clamp permanently connected to it. Optional: supply cable with ring eye
for screwing to earth.

2. Safety instructions

DANGER!
• The rewind cable reel is not allowed to be installed in
zones 0 and 20.
• Never connect under explosive atmosphere.

3. Technical data

Certification according to 2014/34/EU (ATEX)
Conformity to ISO/IEC 80079-34
Protection class
Ambient temperature (T
Case
Compensation conductor
IP protection class
Connecting cable
Dimensions
Weight
EFCO OPERATING INSTRUCTION
Gas
Dust
)
amb
SEV 20 ATEX 0367 X
SEV 20 ATEX 7374
II 2G Ex eb IIC T6 Gb
II 2D Ex tb IIIC T80 °C Db
-40 °C ≤ T
≤ +60 °C
amb
fibreglass-reinforced polyamide
Stainless steel cable Ø 2 mm encased in
PUR Ø 7.75 mm
IP 54
≥ 3 mm
2
L x W x H (300 x 230 x155 ) mm without clamp
3.1 kg incl. clamp
b
12

Advertisement

Table of Contents