  • Page 1 ISO 9001:2015 Instruction Manual Leaders in Dehumidification Unlimited Customisation_______ at Limited Cost...
  • Page 2: Introduction To Product

    I. Important Notices for Safety Before application, please read all the instructions. ● Before application, please confirm that the power supply is 220V/50HZ or 380V/50HZ. ● Do not stop operation of the dehumidifier by pulling out the power cord. ● Be careful with movement of dehumidifier and avoid rolling on and damaging the wire.
  • Page 3 ● Button Function 1. “POWER” button Press this button to start the machine, it enters start-up mode after the buzzer buzzes twice Press this button to stop the machine, it enters stop mode after the buzzer buzzes once 2. “TIMER” button Press this button for once, and it enters the mode of current time setting;...
  • Page 4 can only be stopped after working for at least 3 minutes; the compressor can only be re- started 3 minutes after it stops; 3. If works under low temperature, the dehumidifier may judge the system temperature automatically and defrost automatically; when defrosting, the indicator of defrosting is light, the fan works and compressor stops working.
  • Page 5: Safe Operation And Maintenance

    defrosting for 15 minutes; e. When the system detects that humidity sensor exceeds the limited range, the system enters mode of humidity sensor failure. Under this mode, LCD displays humidity failure code “E2” and the system enters continuous dehumidification. f. After temperature/humidity sensor failure is eliminated, the system works normally. V.
  • Page 6: Operation Notices

    Do not stop operation of dehumidifier by pulling out the power cord. Otherwise fire or electric shock accident may be caused. VI. Operation Notices 1. When moving the machine, do not incline the machine for over 45°to avoid damaging the compressor. 2.
  • Page 7: Warranty

    Humidity sensor failure Warranty Thank you for choosing Indurre dehumidifier. It will bring you great convenience on both work and life. If there is any failure, please contact our repair department or after- sale service center. We will offer you good consultancy and repair service.
  • Page 8 8. Within the warranty period, parts to be replaced must be exchanged with old ones for new ones. TERMS AND CONDITIONS OF WARRANTY 1. This Warranty is applicable to the first purchaser of the product further, the Warranty is applicable only if a defect has been identified to be on account of faulty material or work man ship and not due to improper usage.
  • Page 9 4. The Warranty is effected in Delhi and claims if any, shall be made only before the competent Courts, having jurisdiction in Delhi. No claims what so ever shall be made against the company outside Delhi, not with standing that the product may have sold or delivered or any stipulation or commitment in respect there of may have made elsewhere.