Inlet Station & Remote Dewaterer I N ST A LLAT I O N MA NUA L & R N L E T T A T I O N E M O T E E W A T E R E R SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE CONSERVEZ CES INSTRUCTIONS POUR RÉFÉRENCE ULTÉRIEURE...
Page 2
Unit 1, Abbey Road, Wrexham Industrial Estate, Wrexham, LL13 9RF Declare under our sole responsibility that the following machines; Food Waste Disposers, Impactor Range, Potboy, WastePro, WastePro II, WasteStation, Burnishers, Composters, Inlet Station, Remote Dewaterer and Bench systems As described in the technical construction file (TCF) documentation, are in conformity with the protection requirements of the Electromagnetic Compatibility Directive 2004/108/EC.
IMC as your chosen vendor of choice. IMC is proud to lead the way in terms of ‘green technology’ and to know that together, we can make an important difference in the global war against waste.
Carrier and Supplier immediately if there is a shortage or if an item is damaged. MODEL IDENTIFICATION The IMC Inlet Station & Remote Dewaterer grey water macerator appliances are for use in Commercial establishments only and are for permanent connection.
Page 6
Inlet Station & Remote Dewaterer IMC R EMOTE EWATERER A34/060 – R1 February 2016 P a g e...
Inlet Station & Remote Dewaterer INSTALLATION REQUIREMENTS & SPECIFICATIONS The Inlet Station and Remote Dewaterer require the following electrical and mechanical services for installation ELECTRICAL: Voltage/Frequency: 400V, 3PH, 50 Hz Total Power: 4.1 kW (5.49 hp) The Inlet Station and Dewaterer system contains the following rated motors:...
· This product is to be installed by a qualified IMC appointed installation engineer observing all local and regional codes. · All electrical and water services are to be isolated and locked out before installation or carrying out any remedial work to the IMC Waste appliance.
Inlet Station & Remote Dewaterer INSTALLATION PRIOR TO CARRYING OUT ANY WORK, ENSURE BOTH ELECTRICAL AND OTHER SUPPLY SERVICES ARE ISOLATED Installation of the appliance MUST be carried out in the following chronological order: Selection of site and positioning Waste outlet connection to the main drain.
Inlet Station & Remote Dewaterer Selection Of Site/Positioning & Clearances Select the site of the Inlet Station with care so that it is convenient both for the major source of food waste and for access by machine operators. The machine should be installed as close to the existing drains as reasonably practicable.
Page 11
The IMC Waste appliances require a minimum, 2 persons and the appropriate lifting equipment to position at the site of installation. The IMC Waste appliances can be positioned near to the final place of installation on its shipping pallet, using a pallet truck.
Inlet Station & Remote Dewaterer Waste Outlet Connection The IMC waste appliances are fitted with a standard 51 mm (2”) waste pipe stub outlet for connection to the dedicated waste drain. The IMC Waste outlet is located at the Rear of the Remote Dewaterer unit.
/ length. IMC will provide advice on this. The head of water should not be less than 0.18 bar (1.8m) (18 kPa). The IMC Inlet Station is provided with 2 x ¾” Appliance connections for the Cold water supply at the rear of the machine.
BS6500 must be used. 5.4.3 Run the mains cable to the mains isolator switchbox on the rear of the Inlet Station and connect as shown in figure 3. Run the 3 interconnecting cables from Inlet Station to the Junction Box on the Remote Dewaterer.
Page 15
5.4.4 The Inlet Station system comprises of interconnecting cables that are supplied with the system to power and interface with the Remote Dewaterer. Refer to Figure 4 for the Inlet Station power and interface connection.
Page 16
Inlet Station & Remote Dewaterer Figure 4 - Inlet Station > Remote Dewaterer Interconnection Diagram A34/060 – R1 | 1 6 February 2016 P a g e...
Check that the Emergency Stop button is in the correct ‘OUT’ position – (Turn and release) 5.5.5 Turn on the hot and cold water supplies (Cold (2 off) to Inlet Station, Hot to Remote Dewaterer). Check that there are no water leaks.
Page 18
Inlet Station & Remote Dewaterer A34/060 – R1 | 1 8 February 2016 P a g e...