Extension module for load management
Procont
-LMC-008-IO
®
User manual and technical data

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Procont LMC-008-IO and is the answer not in the manual?

Questions and answers

Summary of Contents for janitza Procont LMC-008-IO

  • Page 1 Extension module for load management Procont -LMC-008-IO ® User manual and technical data Janitza electronics GmbH Vor dem Polstück 6 35633 Lahnau | Germany Support tel. +49 6441 9642-22 info@janitza.de | www.janitza.de...
  • Page 2 Procont -LMC-008-IO ® Procont -LMC-008-IO ® Extension module for load management Doc. no.: 2.100.131.1.a Date: 02/2023 The German version is the original edition of the documentation...
  • Page 3 Nonetheless, we wish to point out that updates of this document are not always possible at the same time as technical refinements are implemented in our products. Information and specifications are subject to change at any time. Please check for the latest version at www.janitza.de.
  • Page 4: Table Of Contents

    Procont -LMC-008-IO ® TABLE OF CONTENTS 1. Information on the device and the user manual ........6 Disclaimer .
  • Page 5 Procont -LMC-008-IO ® 11. Technical data ..............22 11.1...
  • Page 6: Information On The Device And The User Manual

    Copyright notice In addition to this user manual, please refer to ad- ditional usage information for your device, such as: © 2022 - Janitza electronics GmbH - Lahnau. • Installation instructions. All rights reserved.
  • Page 7: Defective Device/Disposal

    · When doing so, please bear the terms for trans- portation in mind. INFORMATION Please return defective or damaged devices to Janitza electronics GmbH in accordance with the shipping instructions for air or road freight (complete with accessories). Do not attempt to open or repair the device (the...
  • Page 8: Safety

    Procont -LMC-008-IO ® Safety The chapter on Safety contains information which Product safety must be observed to ensure your personal safety The device reflects current engineering practice and avoid material damage. and accepted safety standards, but hazards can arise nonetheless.
  • Page 9: Dangers When Handling The Device

    Equip stranded conductors with wire material damage! ferrules! • Do not use Janitza measurement devices or · Hazardous voltages can be present in all circuit- components for critical switching, control or pro- ry parts that are connected to the power supply.
  • Page 10: Electrically Qualified Personnel

    Procont -LMC-008-IO ® Electrically qualified personnel To avoid bodily injury and material damage, only electrically qualified personnel are permitted to work on the devices and their components, mod- ules, assemblies, systems and current circuits who have knowledge of: · The national and international accident preven- tion regulations.
  • Page 11: Product Description

    Please see the EU declaration of conformity post- operation and maintenance in addition to com- ed at www.janitza.de for the laws, standards and pliance with the safety information and warning directives applied by Janitza electronics GmbH for notices.
  • Page 12: Structure Of The Device

    Procont -LMC-008-IO ® Structure of the device Display and connection assignments Item Function/Designation Display (4 lines, background illumination) LEDs for inputs Relay outputs A8-A5, Outputs (load groups) Digital inputs/outputs Supply voltage Status LED for relay outputs A1-A8 LED on -> output is active LED off ->...
  • Page 13: Operation And Key Functions

    Procont -LMC-008-IO ® Operation and key functions The device is operated via a joystick. · Navigation within the menus. · Device configuration. Menu access: To access the settings menu, press the joystick to the right (ENT) for at least 1 second; to return to the main menu press the joystick to the left (ESC) for at least 1 second.
  • Page 14: Rating Plate

    Janitza electronics GmbH Vor dem Polstück 6 35633 Lahnau / Germany Janitza electronics GmbH Made in Austria Vor dem Polstück 6 35633 Lahnau / Germany www.janitza.de Procont -LMC-008-IO ® 16.0f 10/2021 • 16.0f PROCONT-EMC • 6000302 Made in Austria Aux: 100..240V, 50/60Hz 9-15VA /2021 •...
  • Page 15: Assembly And Installation

    Procont -LMC-008-IO ® Assembly and installation DANGER ATTENTION Risk of injury due to electrical voltage! Material damage due to disregard of the instal- Severe bodily injury or death can result from: lation instructions! · Touching bare or stripped leads that are ener- Disregard of the installation instructions can gized.
  • Page 16: Connection

    Procont -LMC-008-IO ® Connection Connecting the expansion module via a ATTENTION network Material damage due to security vulnerabili- The connection to a Procont -LMC /LMC-Lite is ® ties in programs, IT networks and protocols. made via RS-485 or TCP/IP (interface optional).
  • Page 17: Connecting To The Master

    Procont -LMC-008-IO ® Connecting to the master For the connection to the load management LMC(-Lite) LMC-008-IO device (master module), the station number and the assignment of the outputs to the load groups Patch cable Patch cable Switch/Router must be set. The station number is consecutive in a bus, starting with 1 at the master module (LMC/ LMC-Lite).
  • Page 18: Instantaneous Values On The Display

    Procont -LMC-008-IO ® Instantaneous values on the display Symbol Display Function Time and status 10:45:00 10:45:00 Pending alarms; alarms that have already Alarme (Alarms): Alarme (Alarms): been acknowledged but are still active are Alles OK (All OK) Alles OK (All OK) also displayed here.
  • Page 19: System Settings

    Procont -LMC-008-IO ® System settings 10:45:00 10:45:00 Auswahl Auswahl Spr/Lng: Spr/Lng: Spr/Lng: Spr/Lng: T-Sper T-Sper (Selection): (Selection): German German German German (Key lock):N (Key lock):N System System (back-light):Aut. (back-light):Aut. Grundb Grundb Spr/Lng: Spr/Lng: (Home (Home German German screen):1 screen):1 Sprache/Lan.
  • Page 20: Alarms On The Display

    Procont -LMC-008-IO ® Alarms on the display States of the alarms. Pending alarms can be acknowledged using 1.5 sec "ENT" (Enter). To do so, press the joystick to the right for 1.5 seconds. Alarm Error Ext.Bus Bus failure of a bus device Not-Aus Emergency stop alarm.
  • Page 21: 10. Network Settings

    Procont -LMC-008-IO ® 10. Network settings 10:45:00 10:45:00 Auswahl Auswahl Spr/Lng: Spr/Lng: Spr/Lng: Spr/Lng: T-Sper T-Sper (Selection): (Selection): German German German German (Key lock):N (Key lock):N System System (back-light):Aut. (back-light):Aut. Grundb Grundb Spr/Lng: Spr/Lng: (Home (Home German German screen):1...
  • Page 22: 11. Technical Data

    Procont -LMC-008-IO ® 11. Technical data General Net weight approx. 300 g (0.66 lbs) Device dimensions W x D x H W = 105 mm (4.13 in), H =  86 mm (3.39 in), D = 60 mm (2.35 in) Display 8 digits, 2 lines, LCD display with backlight...
  • Page 23 Procont -LMC-008-IO ® RS-485 interface 3-conductor connection with A, B, GND Protocol Modbus RTU Transmission rate 9.6 kbps, 19.2 kbps, 38.4 kbps Ethernet interfaces LAN 100Base-T Connection 1 x RJ45 Protocols and services Modbus TCP Terminal connection capacity (plug-in) Connectible conductors. Only connect one conductor per terminal point! Single core, multi-core, fine-stranded 0.2 - 2.5 mm...
  • Page 24: Dimensional Drawings

    170 mW Front view thernet LAN 100Base-T RJ45, RS485 Stellen, 2 Zeilen LCD-Display mit Hintergrundbeleuchtung -Achsen Joystick a. 300 g PROCONT LMC-008-IO atensicherung und automatischer Wiederanlauf Max. 4 VA (24 VDC , 150 mA) Made in Austria 106 6TE Side view (Irrtum und technische Änderungen vorbehalten)
  • Page 25: Connection Diagrams

    -LMC-008-IO and boiler semiconductor contactor up to 4 ® 230/400 VAC Control voltage 24 VDC Potental free relais contacts HW-Boiler/Buffer (250 VAC 6 A) E-heating 230/400 VAC PROCONT LMC-008-IO PROCONT LMC-008-IO HW-Boiler/Buffer E-heating Potental free relais contacts (250 VAC 6 A)
  • Page 26: Example Procont ® -Lmc-008-Io And Relay Contactor Up To 8

    Procont -LMC-008-IO ® 11.2.2 Example Procont -LMC-008-IO and relay contactor up to 8 ® Control voltage 24 VDC PROCONT LMC-008-IO PROCONT LMC-008-IO Seite - 15 - von 20...
  • Page 27: 12. Maintenance And Service

    You can reach us: Monday to Thursday between 07:45 am and 5:00 pm and on Friday between 07:45 am and 3:00 pm Janitza electronics GmbH Vor dem Polstück 6 35633 Lahnau, Germany Support. Tel: +49 6441 9642-22 Email: support@janitza.de Website: www.janitza.de...
  • Page 28 Vor dem Polstück 6 | 35633 Lahnau Germany Tel: +49 6441 - 9642-0 info@janitza.de | www.janitza.de Doc. no. 2.100.131.1.a | 02/2023 | Subject to technical alterations. The current version of the document can be found in the download area at www.janitza.de.