Quick Links

Isotemp Basic water heater has been designed and
produced to ensure that your water heater will give
long and trouble free operation for many years.
It is important, however, that your Isotemp water
heater is correctly installed and maintained. During
the winter period when the unit is not being used it is
essential that it is drained to avoid risk of damage
due to freezing.
Every single Isotemp water heater is individually
pressure tested prior to delivery and carries a 2 year
factory warranty in respect of defects in material
and/or manufacture and a limited 5 year warranty on
the inner tank.
Installation:
1. Placement:
The water heater may be placed in a suitable place with the engine water connectors on the water
heater below the level of the engine header tank. The connection hoses between the engine and the water heater
should be kept as short as possible
2. Mounting:
The water heater can be mounted horizontal, with the safety valve lowest, or vertical with all connec-
tions pointing downwards. The mounting brackets can be turned to fit the bottom or a bulkhead on board. Bear in
mind the weight of the unit when full of water.
3. Water connections:
3.1 Fittings:
Use only fittings and accessories made of non-corrosive material such as brass or stainless steel. Avoid
plastic fittings on the water heater depending on the heat. For the engine cooling water connections, use heat resis-
tant (100°C/210°F) reinforced rubber hoses, resistant to anti-freeze and pressure proved for 5 bar (70 psi). For the
fresh water, use heat resistant fresh water hoses (food industry quality). They shall be rated 8 bar (115 psi).
Seal the threaded connections with e.g. LocTite 243.
3.2 Engine connections (see schedule):
engines. The flow of cooling water from the engine through the water heater must be at least 2 litres/min. If the boat
has two engines, connect the water heater to one engine only.
Connection to the engine shall be done with min. 16 mm / 5/8" hoses and adaptors to avoid restrictions. See the in-
structions in the engine operators manual, regarding hose connection points.
I-61019 S Agata Feltria (PU)
Italy
Phone +390541848030
Fax +390541848563
Operators manual
Basic water heater
.
The water heater may be used with either fresh or sea water cooled
info@indelmarine.com
www.isotherm.com

Advertisement

loading

Summary of Contents for Indel Marine Isotemp Basic

  • Page 1 Operators manual Basic water heater Isotemp Basic water heater has been designed and produced to ensure that your water heater will give long and trouble free operation for many years. It is important, however, that your Isotemp water heater is correctly installed and maintained. During...
  • Page 2: Maintenance

    (EU plug), which should be fitted to a correctly installed socket. This socket as all ”high-voltage” installations on board, must be carried out to fulfil valid regulations. The Isotemp Basic water heater is designed to meet EU regulations in this field.
  • Page 3: Immersion Heater

    Technical data Isotemp Basic Type Volume lit. L x øD x H mm Weight kg Immersion heater 602431B000003 490 x 390 x 395 230V/750W 603031B000003 555 x 390 x 395 230V/750W 604031B000003 660 x 390 x 395 230V/750W 605031B000003 780 x 390 x 395...
  • Page 4: Wiring Diagram

    Principal connection diagram Engine coolant Engine Water tap coolant Hot water out Pressure water pump Cold water in Safety valve Fresh water tank Wiring diagram Over heat protection Thermostat Heating element Brown Blue Yellow-green...
  • Page 5 Thermostats Overheat thermostat, Re-set button under white cap. Operation thermostat ENGINE WATER ACQUA MOTORE FRESH COLD WATER IN INGRESSO ACQUA FREDDA Safety valve with drainage.

This manual is also suitable for: