Inverter Heat Pump Installation & Operation Manual EC 12KW EC 16KW EC 20KW EC 24KW Should the installer or owner be unfamiliar with the correct installation or operation of this type of equipment, you should contact the distributor/manufacturer for the correct advice before proceeding with the installation or operation of this product.
Page 2
Support Contact CUSTOMER SERVICE / TECHNICAL SUPPORT If you have questions about ordering Maytronics Ecoclear® replacement parts, and pool prod- ucts, please contact: Head Office: Brisbane, Queensland Address: 2/91 Rudd Street (entry off Boundary Road), Oxley QLD 4075 Phone Number: 1300 693 657 Email: infoau@maytronics.com...
Notices and Warnings Important Notice This manual provides installation and operation instructions for the prod- uct. Consult Maytronics with any questions regarding this product. Attention Installer: This manual contains important information about the installation, opera- tion and safe use of this product. Leave this manual with the owner and/ or operator of this product after installation.
Page 5
Notices and Warnings Notices and Warnings (Continued) The unit should be located on a solid, level, horizontal surface and se- WARNING curely fixed. Ensure free air-flow to all sides of the unit. Never use an extension cable to connect the unit to the electric power supply WARNING If there is no suitable earthed supply available, have one installed by a...
Contents and Overview Contents • Heat Pump Unit • Owners Manual • Barrel unions x2 • Drain Hose x1 • Anti-vibration pads x4 Overview The swimming pool heat pump is one of the most economical ways of heating your swimming pool ef- ficiently.
Installation Installation Only a qualified service person should install the Ecoclear® Heat Pump. Before installing this product, refer to the Important Warning and Safety Instructions on page 4. Materials Needed for Installation The following items are needed and are to be supplied by the installer for all heat pump installations: 1.
Installation Location and Clearances All criteria given in the following sections reflect minimum clearances. However, each installation must also be evaluated, taking into account the prevailing local conditions such as proximity and height of walls, and proximity to public access areas. The Ecoclear® Heat Pump must be placed to provide clearances on all sides for maintenance and inspection.
Installation Anchor Clamp Installation (Continued) 4. Mark the position of the hole in each clamp on the equipment pad. 5. Use a masonry drill bit and drill a hole in the cement with a diameter as determined by the concrete anchor, at each of the marks on the equipment pad. The hole should be approximately 40mm deep.
Note: Be advised that when pool equipment is located below the pool surface a leak can re- sult in large-scale water loss or flooding. Maytronics is not responsible for such water loss or flooding or damage.
Installation Plumbing Connections - Separate Circulation System The Ecoclear® Inverter Heat Pump can also be connected on plumbing separate to the main filtration system. In this configuration the pump will take water from separate pool outlets and flow directly into the heat pump. A filter is not essential in this configuration, however it may be required in circumstances where there is large debris in the water, or poor water quality, which could cause blockages in the heat pump.
Installation Multiple Heater Type Installation The Maytronics Ecoclear® heat pump may be used in conjunction with a gas or electric heater or any combination of heat sources including solar. When using multiple heater types, all heat sources should be plumbed in series to work correctly and efficiently. A recommended plumb- ing layout for a heat pump / heater / solar combination heating system for a pool / spa com- bination is shown below.
Installation Electrical Connections General Information Wiring connections must be made exactly as shown in the wiring diagram found on the inside of the heat pump access panel; see the wiring diagrams on page 35. The Ecoclear® Inverter Heat Pump must include a definite means of grounding and bonding. There is a ground lug inside the heat pump electrical compartment.
Page 16
Installation Electrical Connections (Continued) Figure 10: Location of Electrical Panel 1. Water Pump Active 2. Water Pump Neutral Figure 11: Electrical Connections for Single Phase Units Inverter Heat Pump Owner’s Manual...
Configuration Configuration Control Panel Figure 12: Control Panel Ref Icon Function Key / Lock Tap the key to lock the screen. Hold the padlock for 3 seconds to unlock the screen. On/Off Tap to turn the heat pump on or off. Time This shows the current time.
Page 18
Configuration Control Panel (Continued) Figure 13: Control Panel Menu Screen Ref Icon Function Settings Tap this to enter the settings menu. Status Tap to enter the status menu. Timer Tap to enter the timer menu. For setting the on/off timer. Clock Tap to enter the clock menu for setting the system time.
Configuration Setting the Clock 1. On the main interface screen, swipe left and to enter into clock setting interface. 2. Tap the date. This will this take you to the date setting interface. Swipe up and down on the Month, Day and Year to select the correct date.
Configuration Turning Heat Pump On and Off When the heat pump is off, the main screen will have a black background and display “OFF” in the centre. To turn the heat pump on, tap the power button . The background will change to blue and the current temperature will be displayed on the screen, indicating the heat pump is on.
Configuration Setting the On/Off Timer The timer option will start and stop the heat pump at the specified times. The heat pump still requires water flow to operate. If there is a water circulation pump connected to the heat pump, the timer will also start the water circulation pump.
Configuration Status Query Important parameters of the heat pump’s current status can be viewed on the status screen. 1. On the main interface screen, swipe left and to enter into the status menu. 2. Tap the status button to enter the sta- tus display.
Configuration Scenario (Operating Mode) The Ecoclear® Inverter Heat Pump has multiple operating modes to optimise the performance and efficiency: 1. On the main interface screen, swipe left and to enter into Scenario setting inter- face. 2. Tap the desired scenario mode. 3.
Automation Connection Connecting the Heat Pump to Automation To connect the external control cable plug to the motherboard: 1. Run a two-conductor cable from the heat pump external control to the low voltage race- way to the motherboard in the Pentair Automation control centre. 2.
Page 25
Automation Connection Connecting the Heat Pump to Automation (Continued) Connect 2-core 1mm2 cable to heat pump “REMOTE” terminals. AUTOMATION WIRING FOR HEAT PUMP ONLY Connect to Relay for Solar Pump (for seperate solar pump system) Solar To solar diverter Connect 2-core 1mm2 cable to heat pump valve actuator “REMOTE”...
Failure to properly maintain your unit can void the warranty. Owner Inspection Maytronics recommends that you inspect your heat pump on a continual basis and especial- ly after abnormal weather conditions. The following basic guidelines are suggested for your inspection: 1.
Maintenance & Troubleshooting Maintenance & Troubleshooting Continued professional technician to inspect the heat pump and replace any part of the control sys- tem which has been submerged. The Ecoclear® Heat Pump will produce condensation (water) while in operation. The heat pump base is designed to allow the condensation to exit through the bottom drain port when the unit is running.
Page 28
Maintenance & Troubleshooting Maintenance & Troubleshooting Continued 5. Cover only the top of the heat pump to prevent debris from falling into the unit. Do not wrap the sides of the heat pump with any plastic or other material that will retain heat or moisture inside the unit.
L5 and L7 on the motherboard. This will connect the flow switch to the automation input. If you cannot correct the fault yourself, please contact Maytronics for after-sales service. Inverter Heat Pump Owner’s Manual...
Maintenance & Troubleshooting System Protections / Error Codes When a fault occurs, the fault icon in the main interface will flash. When an error occurs or the protection mode is set automatically, the wired controller will display an error code as below. To view fault codes, swipe left and tap .
Page 31
Maintenance & Troubleshooting System Protections / Error Codes (Contin- Code Fault Message Possible reasons Remedy Antifreeze Temp. Sensor Antifreeze temp sensor is Check or change the tem- Fault broken or short circuited. perature sensor. Pressure Sensor Fault The pressure sensor is bro- Check or change the pres- ken.
Page 32
Maintenance & Troubleshooting System Protections / Error Codes (Contin- Code Fault Message Possible reasons Remedy F032 Fan Motor2 Fault 1. Motor is in locked-rotor 1.Change a new fan motor state. 2.Check the wire connec- 2.The wire connection be- tion and make sure they tween fan controller and are in good contact.
Page 33
Maintenance & Troubleshooting System Protections / Error Codes (Contin- Code Fault Message Possible reasons Remedy IPM Sampling Cur. IPM sampling electricity is Check and adjust the cur- fault. rent measurement Inv. Temp. Probe Fail Sensor is short circuit or Inspect and replace the open circuit.
Environmental Information Environmental Information This equipment contains fluorinated greenhouse gases covered by the Kyoto Protocol. It should only be serviced or dismantled by professional trained engineers. This equipment contains R32 refrigerant in the amount as stated in the specification. Do not vent R32 into the atmosphere: R32, is a fluorinated greenhouse gas with a Global Warming Potential (GWP) = 677.
Page 40
IMPORTANT Please attach your sales invoice/docket here as proof of purchase should warranty service be required. Please do not return warranty form to Maytronics Australia – Retain for your records. PURCHASED FROM: PURCHASE DATE: SERIAL NO: MODEL NO: Unit 2/91 Rudd Street, Oxley, QLD 4075 | Australia | 1300 693 657 | www.maytronics.com.au Information contained here in remains the property of Maytronics Australia under Australian copyright law.