FOR 2000 SERIES WITH QUANTUM AND 2100 - 9100 SERIES
THIS KIT MUST BE INSTALLED BY A QUALIFIED TECHNICIAN
NOTE: If possible, record the Configuration settings before removing
the existing processor control board. This will aid in the
installation of the new processor control board. Reference the
Configuration Menu on Pages 7-8.
1. De-energize the Steffes heating system.
2. Remove the electrical panel cover (painted front panel on 2000 Series
with Quantum and 2100 Series).
3. Disconnect the wiring harness(es) located at the bottom of the board.
4. Disconnect the interface cable (RJ45 connection).
5. 2000 w/Quantum/2100/3100/4100/5100/E5100 Series Systems Only: Remove the thermocouple wiring
(brick core sensor and discharge air on 2100 Series) from the 4-position terminal block on the existing
processor control board.
NOTE: It is extremely important to note the position of any
wires in these locations as they are critical to
system operation and are polarity sensitive.
6. Remove the existing board from the mounting bracket.
7. Mount the new processor control board on the existing bracket.
NOTE: Position nylon washer as shown in Figure 1.
8. Connect the wiring harness(es) and interface cable in the proper
positions.
9. Reconnect the thermocouple wiring (brick core sensor wires and
discharge air on 2100 Series).
NOTE: The thermocouple wires MUST be positioned correctly to ensure proper operation of the
system. See Owner's/Installer's Manual, low voltage wiring diagram, for more information.
10. Re-install the electrical panel cover or painted front cover.
11. Go to the appropriate page of these instructions for the heating system being serviced:
2000 Series Quantum
2100 Series
3100/4100/5100/E5100 Series
6100/7100/8100 Series
9100 Series
Item #1023065R (PCB Control Board Universal)
INSTALLATION
Page 2
Page 3
Page 4
Page 5
Page 6
Page 1 of 16
PROCESSOR CONTROL
BOARD INSTALLATION
Software Version 2.08 or Higher
WARNING
Risk of electric shock. Can
cause injury or death. This
heating system may be
connected to more than one
branch circuit. Disconnect
power to all circuits before
servicing.
FIGURE 1
Document # 1200445 Rev 11
08/10/2022

Advertisement

loading
Need help?

Need help?

Do you have a question about the 1023065R and is the answer not in the manual?

Questions and answers

Summary of Contents for Steffes 1023065R

  • Page 1 BOARD INSTALLATION Software Version 2.08 or Higher FOR 2000 SERIES WITH QUANTUM AND 2100 - 9100 SERIES Item #1023065R (PCB Control Board Universal) THIS KIT MUST BE INSTALLED BY A QUALIFIED TECHNICIAN INSTALLATION NOTE: If possible, record the Configuration settings before removing WARNING the existing processor control board.
  • Page 2 4. Set the value of Location 98 (L098) to the appropriate value shown in Table 1. The values correspond to the Steffes heating system series and geographic location. Location 98 (L098) will revert to a value of zero (0) upon leaving the location.
  • Page 3 4. Set the value of Location 98 (L098) to the appropriate value shown in Table 3. The values correspond to the Steffes heating system series and geographic location. Location 98 (L098) will revert to a value of zero (0) upon leaving the location.
  • Page 4 3. Set the value of Location 98 (L098) to the appropriate value shown in Table 5. These values correspond to the Steffes heating system series and geographic location of the system. Location 98 (L98) will revert to a value of zero (0) upon leaving the location.
  • Page 5 3. Set the value of Location 98 (L098) to the appropriate value shown in Table 7. These values correspond to the model of Steffes heating system. Location 98 (L098) will revert to a value of zero (0) upon leaving the...
  • Page 6 3. Set the value of Location 98 (L098) to the appropriate value shown Initial Location 98 Setup in Table 10. These values correspond to the model of Steffes Values heating system. Location 98 (L098) will revert to a value of zero (0) upon leaving the location.
  • Page 7: Configuration Menu

    CONFIGURATION MENU Steffes heating systems have a Configuration Menu, which allows the systems to be customized to the power company and consumer’s needs. This menu can be accessed on start-up and allows configuration settings to be easily adjusted.
  • Page 8 C003 Power Line Carrier (PLC) Channel Selection - If using PLC communication, this setting must match the channel setting in the Steffes PLC transmitting device. A value of zero indicates PLC is disabled. C004 Optional Controls Configuration...
  • Page 9: Installation

    « Menu de configuration » aux pages 15-16. TENSIONS DANGEREUSES : Risque de décharge électrique, 1. Fermer l’alimentation électrique du système de chauffage Steffes. de blessure ou de mort. Ce 2. Retirer le couvercle du panneau électrique (panneau avant sur les système peut être branché...
  • Page 10 4. Configurer la valeur du canal L098 en se référant aux données du tableau 1. Ces valeurs correspondent à différents systèmes de chauffage Steffes et emplacements géographiques. Le canal L098 est réinitialisé à une valeur de 0 après avoir quitté la configuration du canal.
  • Page 11 4. Configurer la valeur du canal L098 en se référant aux données du tableau 14. Ces valeurs correspondent à différents systèmes de chauffage Steffes et emplacements géographiques. Le canal L098 est réinitialisé à une valeur de 0 après avoir quitté la configuration du canal.
  • Page 12 Configurer la valeur du canal L098 en se référant aux données du tableau 16. Ces valeurs correspondent à différents systèmes de chauffage Steffes et emplacements géographiques. Le canal L098 est réinitialisé à une valeur de 0 après avoir quitté la configuration du canal.
  • Page 13 6100 tableau 18. Ces valeurs correspondent à différents systèmes de chauffage 7100 Steffes et emplacements géographiques. Le canal L098 est réinitialisé à une 8100 valeur de 0 après avoir quitté la configuration du canal. NOTE : Pour savoir comment consulter et/ou modifier les valeurs des canaux, voir la page 15.
  • Page 14 3. Configurer la valeur du canal L098 en se référant aux données du statique intégré tableau 21. Ces valeurs correspondent à différents systèmes de (fabriqués après chauffage Steffes et emplacements géographiques. Le canal L098 7/1/2021) est réinitialisé à une valeur de 0 après avoir quitté la configuration du canal.
  • Page 15: Menu De Configuration

    Menu de Configuration Les systèmes de chauffage Steffes disposent d’un menu de configuration qui leur permet d'être personnalisés selon les besoins du fournisseur d'électricité et des consommateurs. Ce menu est accessible au démarrage et sa convivialité...
  • Page 16 C005 Configuration de l’interrupteur de commande – Si le système utilise la commande par signaux de communication à courants porteurs (PLC), un module d’horloge Steffes ou la commande par signal haute tension, la valeur doit être « 0 ». Pour toutes les autres applications, la valeur doit être « 1 ».