1. INTENDED USE
This product is for lighting purposes only and: -may only be mounted radiating downwards -can be installed indoors and outdoors -has
protection class IP65, suitable for use in damp areas -must not be exposed to strong mechanical loads or heavy soiling -may not be
operated after damp or dirty storage until after a condition check -may not be changed or modified, otherwise the operating permit and
conformity will expire with immediate effect! It is not allowed to remove the type plate.
 If the aforementioned points are not observed, a short circuit or electric shock may occur! There is danger to life!
2. GENERAL SAFETY INSTRUCTIONS
 The complete installation may only be carried out by an authorized electrician who is familiar with the applicable guidelines.
Hereinafter referred to as „qualified electrician".
 For safe handling of the product, the user must have read and understood the installation/operating instructions completely before
using the device for the first time.
 The product may only be used if it is alright. If the device or parts of it are defective, it must be repaired by a qualified electrician.
 Only use lamps/light source approved by the manufacturer. The max. lamp wattage in watts is not allowed be exceeded.
 Safe operation of the product is only guaranteed if these instructions are followed. Therefore, keep these assembly/operating
instructions. SSC-LUXon GmbH accepts no liability if the instructions given here are not followed or the lamp is subjected to
improper use.
3. TECHNICAL DATA / EXPLANATION OF SYMBOLS
Model:
RW-1 (round) | QW-1 (square)
Voltage:
12V oder 230V / 50Hz
Description:
Recessed light
Protection type:
IP65
Light source:
LED module
Material:
Aluminium / steel
Measurements:
Ø 84mm | 84x84mm
Cutout:
68mm
Installation depth incl.
50mm
module-model 5W:
Rotation range:
-
Swivel range:
-
4. ASSEMBLY and CONFIGURATION
 Caution: The connecting cable must be disconnected from the power supply before starting work (switch off the main switch/fuse)!
Only use parts which are supplied with the product or which are clearly marked as equipment! Otherwise the product may not be
sufficiently safe!
 The cable routing shown in the illustrations is for simplified purposes only. They in no way represent a recommendation for
connection! The connection may only be carried out by a qualified electrician.
 When drilling, pay attention to cables and gas and water lines. Always route the cable so that it does not touch the luminaire. Fig.5.2
Assembly location:
The product is suitable for installation in suspended ceilings. The product may only be installed on a stable, tilt-resistant and level
surface. The minimum distances in Fig. 5 must be observed! Sufficient air circulation must be ensured! Do not cover the product
under any circumstances, especially not with insulating material! Fire hazard Fig.5.1!
 Components of the luminaire and especially the lamps/light sources become hot during operation. Especially in the case of
halogen lamps/light sources. Keep a sufficient distance (0.5 m) from easily flammable objects (e.g. curtains, drapes, etc.) and
flammable materials (ignition temperature<250°C)!
Individual assembly steps:
1. Measure and cut out the cut-out (Ø see technical data table) (Fig.1)
2. Insert the bulb into the recessed luminaire as follows: Fig.2.1 - Pull off part A from part B; Fig.2.2 - Guide the lamp sideways into the
holder; Fig.2.3 - Put part A back onto part B
3. Connect the mains cable (Fig.3)
4. Push the spring clips upwards and insert the lamp into the cut-out (Fig.4.a + b)
5. Suitable for ceilings of 3-20mm thickness (Fig.5)
6. Make sure that the product cannot fall down after assembly!
7. The product is now ready for use
5. OPERATION, BULB REPLACEMENT, FAULTS & DISORDERS
 Never look directly into the light source!
 Replacement of lamps/light sources:
Caution: Disconnect the connecting cable from the power supply before replacing lamps/light sources!
Halogen lamps/lamps become very hot during operation - risk of burns! Therefore, do not touch the protective glass or the reflector!
Allow to cool down before replacing! Do not cover! There is a risk of fire when covering (e.g. with towel)! Lamps with protective cover
may only be operated with complete protective cover!
What to do in case of error?
In case of an error, the device must be switched off immediately. The product may only be operated if it works correctly. The device may
only be put back into operation after it has been checked by a qualified electrician! This is the case if:
1. there is visible damage, 2. the product is not working corrctly, 3. there is smoke, steam, or audible crackling noises, 4. overheating can
Distance to illuminated objects
be detected
min. 0.5m
 Caution: There is a danger to life - repairs to the product or work on parts carrying mains voltage may only be carried out by
qualified electricians.
Protection class II
Avoidance of disturbances and fire hazards:
It is not allowed to cover the product under any circumstances. Air circulation must be ensured. Nothing may be attached or hung on
Can be used indoors and
the product, especially no decoration.
outdoors.
6. CLEANING & CARE INSTRUCTIONS
Do not cover with insulating
material
The product may only be wiped dry or carefully with a slightly damp and lint-free cloth. The product is not allowed to be removed for
this purpose. Do not use abrasive or sharp objects or aggressive cleaning agents. Do not use solvents.
Installation only by qualified
electrician
7. DISPOSAL INSTRUCTIONS
Disconnect the device from the
mains power before starting any
Keep packaging material and small parts away from children and animals. Danger of suffocation!
work
Make sure to dispose packaging in accordance with the applicable guidelines of your local authority. Devices marked with the
crossed-out waste garbage do not belong in the household waste! You are obliged to hand in these devices at one of the free
collection points in your municipality. You can obtain more information from your local authority, the relevant town hall or a
local or regional waste disposal company.

Advertisement

loading
Need help?

Need help?

Do you have a question about the RW-1 and is the answer not in the manual?

Questions and answers

Summary of Contents for SSC-LUXon RW-1

  • Page 1  Safe operation of the product is only guaranteed if these instructions are followed. Therefore, keep these assembly/operating may only be operated with complete protective cover! instructions. SSC-LUXon GmbH accepts no liability if the instructions given here are not followed or the lamp is subjected to improper use.
  • Page 2 Fig.2.3 Fig.3 Fig.1 Fig.2 Fig.2.2 Fig.4 Fig.4 Cutout Ø see table Fig.5.1 Fig.5.2 Fig.5 Please note: For 230V power supply, keep a minimum distance of 2.25 m between floor and ceiling!

This manual is also suitable for:

Qw-1