TFP ELIMINATOR
Installation & Operating Instructions for
ME500XF, ME500XC, ME800XF, ME800XC, ME1400XF, ME1400XC, ME1400XCM,
ME2000XC, ME2000XF, ME2500XCR, ME2500XFR, ME4000XF, ME4000XC, ME6000XF,
ME6000XC
Features
High efficiency collection for wet mist
Low power consumption
motors available in various voltages
Durable epoxy powder paint
Low maintenance
Easy to change collectors
Compact design
rd
Optional 3
stage filters
Applications
Machining centers
Boring mills
Screw Machines
Die casting machines
High speed grinders
Mounting
1. The TFP ELIMINATOR can be suspended from above, attached directly to the top of
the machine or bolted to a support frame. Make sure that the support has adequate
strength. For congested areas, purchase the column mount which will fit into a small
floor space and will place the TFP-ELIMINATOR 7 feet above the floor.
2. To provide access for maintenance, a minimum clearance of 30" (77cm) is required
above the ME500XF, ME800XF, ME1400XF, ME1400XCM, ME2000XF, ME2500XFR,
and ME2500XCR. The minimum clearance above the ME4000XF and ME6000XF is
50" (127 cm).
3. When suspending the smaller units ME500, ME800, ME1400, ME2000XF and
ME2500XC and ME2500XF series units, use the four mounting holes at each top
corner. A chain or cable can be attached to these holes to suspend the unit from
overhead steelwork. When mounting on a support frame, bolt to the frame using the
four holes at the bottom of the ME500XF, ME800XF, ME1400XF, ME2000XF,
ME2500XC and ME2500XF series units and the eight holes at the bottom of the
ME4000XF and ME6000XF units.
1 of 10
TFPS V8
12/03/09