Pro-Sensor Automatic and Manual Lifejacket Inflators Safety Information UML RECOMMENDS THAT LIFEJACKETS ARE WORN BY ALL CREW MEMBERS AT ALL TIMES ABOARD THE VESSEL BEFORE EACH USE: Ensure all crewmembers are fully aware how the Lifejacket operates and also how to manually activate the Lifejacket.
• Simple re-charging procedure. • The Automatic Pro-Sensor is fitted with the latest 'all weather' Cartridge with the added benefit of inhibiting the accidental ingress of moisture and water spray, during hot humid or heavy stormy weather. •...
Page 4
Pro-Sensor Automatic and Manual Lifejacket Inflators How the Automatic version works The UML Automatic system activates when the Cartridge Mechanism comes into contact with water. • The cartridge mechanism is a compressed high powered spring which is held by a paper element.
Page 5
Pro-Sensor Automatic and Manual Lifejacket Inflators How the Automatic version works cont. • When the system has fired automatically the indicator system turns to red, sensing the cartridge has activated and the CO cylinder has been pierced. The indication system will only show green when the product is correctly charged.
Page 6
Pro-Sensor Automatic and Manual Lifejacket Inflators The sensing elements of the Indicator Inflator. When the cylinder is not correctly fitted the indicator will show red. When the firing cap is not correctly fitted the indicator will show red. When the firing cap has activated the indicator will show red.
Page 7
Pro-Sensor Automatic and Manual Lifejacket Inflators How the Manual Inflator works The UML Manual system activates when the pull tab is pulled. • The pull tab is connected to a lever which pushes a plunger forward, in turn forcing a cutter into the CO cylinder.
Page 8
Pro-Sensor Automatic and Manual Lifejacket Inflators Getting familiar with your lifejacket and Inflator Testing Your Lifejacket with the UML Pro-Sensor Automatic Inflator. • If you want to test your life jacket in the water. Open the lifejacket following the manufacturers instructions •...
Page 9
Pro-Sensor Automatic and Manual Lifejacket Inflators Rearming your UML Pro-Sensor Automatic Inflator • Take the new automatic cartridge and screw onto • If fired manually replace the firing arm into the unit. the inflator head in a clockwise direction. Screw right up...
Page 10
Pro-Sensor Automatic and Manual Lifejacket Inflators Getting familiar with your lifejacket and Inflator Testing Your Lifejacket with the UML Pro-Sensor Manual Inflator. • If you want to test your life jacket in the water. Open the lifejacket following the manufacturers instructions •...
Page 11
Pro-Sensor Automatic and Manual Lifejacket Inflators Rearming your UML Pro-Sensor Manual Inflator • When manually fired replace the firing arm into the unit. The arm will click into place, thereby preventing the arm from moving. BLACK WASHER • Check that the cylinder sealing gasket in the end of •...
Page 12
Service and maintenance of your Pro-Sensor Inflators UML Automatic Pro-Sensor Inflator • The UML Automatic cartridge and CO cylinder need replacing after use. • The cartridge must be replaced after 3 years, the expiry date is indicated on the cartridge.
Page 13
Pro-Sensor Automatic and Manual Lifejacket Inflators Ask your dealer for replacement kits • Contact your local dealer to obtain the correct replacement kit The re-charge kit will contain: • The correct CO Cylinder type and size. • An Automatic Cartridge •...