AIR SCRUBBER MODEL: AAS 800 OWNER’S MANUAL SAVE THESE INSTRUCTIONS FOR FUTURE REFERENCE...
Page 2
OWNER’S MANUAL AAS800 AIR SCRUBBER READ AND SAVE THESE INSTRUCTIONS The Air Scrubber is the most compact, portable unit in our popular line of high performance airscrubbers. The Air Scrubber features a 22” x 24” footprint and stands only 14” tall. Weighing less than 35 lbs and featuring a molded handle and stackable design, the Air Scrubber is easy to carry, transport, and store.
OWNER’S MANUAL AAS800 AIR SCRUBBER SPECIFICATIONS Part No. AAS800 Power 240 V, 0.7 A, 170 W Blower 500 CFM Filters: 1st stage 1"Pleated Media, 18" x 18" (optional) 1" Carbon and Potassium Permanganate 2nd stage 2.5" Pleated HEPA 18" x 18" Warranty One Year, 100% Parts and Labor Dimensions Width 22"...
OWNER’S MANUAL AAS800 AIR SCRUBBER OPERATION Transporting the Air Scrubber The Air Scrubber should be transported vertically or horizontally on the appropriate feet located on the bottom of the unit or opposite the handle Electrical Requirements The Air Scrubber can be plugged into a grounded 15 Amp circuit. It draws about 2 Amps with clean filters and no ducting.
Page 5
OWNER’S MANUAL AAS800 AIR SCRUBBER OPERATION CAUTION CAUTION: Exhausting too much air from a space with open combustion devices (e.g. furnace, fireplace or water heater) can cause those devices to backdraft. This can contaminate the space with potentially fatal gases. In such cases, the Air Scrubber must be used in one of the following three ways: A.
Page 6
OWNER’S MANUAL AAS800 AIR SCRUBBER OPERATION Resettable Circuit Breaker The 12 AMP thermal response resettable circuit breaker protects the unit and devices connected to its duplex GFCI outlet. The circuit breaker is designed to sense the total current draw through the circuit. The circuit breaker "trips"...
OWNER’S MANUAL AAS800 AIR SCRUBBER MAINTENANCE WARNING Use extreme caution when changing the HEPA filter as hazardous material could be trapped in the media. Always make sure to dispose of filters in the appropriate way. If you are unsure of how to safely dispose of any filter-consult an industrial hygienist to ensure that all hazardous materials are contained and disposed of properly.
OWNER’S MANUAL AAS800 AIR SCRUBBER MAINTENANCE Optional Activated Carbon/Potassium Permanganate Filters They use a blend of activated carbon and potassium permanganate. This blend removes the vast majority of gaseous contaminants encountered in most filtering applications. The activated carbon removes the heavier volatile organics while the potassium permanganate removes lower molecular weight contaminants.
Page 9
OWNER’S MANUAL AAS800 AIR SCRUBBER ITEM No ITEM No DESCRIPTION DESCRIPTION Screw Strain relief-lq tight Rubber foot Power cord Removable Foam Cap Nut, hex Upper half shell Circuit breaker Buckle Filter net plug alarm lamp Primary efficiency filter AC motor High efficiency filter Fan blade Fixed buckle...