Download Print this page

Advertisement

Quick Links

QUICK START
GATE 1 DG R2BF
GATE 1 DG R2EF
GATE 1 DG R3BF
FULL MANUAL
(Rev. 15)
&
SAFETY
INFORMATION
SEA USA Inc.
10850 N.W. - 21st - unit 160 - Doral - MIAMI - Florida (FL) - 33172 - USA
Telephone
: ++1-305.594.1151
-
++1-305.594.7325
Toll free:
800.689.4716
www.sea-usa.com
sales@sea-usa.com
67412252
REV. 00 - 06/2022

Advertisement

loading
Need help?

Need help?

Do you have a question about the GATE 1 DG R2BF and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for SEA USA GATE 1 DG R2BF

  • Page 1 QUICK START GATE 1 DG R2BF GATE 1 DG R2EF GATE 1 DG R3BF FULL MANUAL (Rev. 15) & SAFETY INFORMATION SEA USA Inc. 10850 N.W. - 21st - unit 160 - Doral - MIAMI - Florida (FL) - 33172 - USA Telephone : ++1-305.594.1151...
  • Page 2: Technical Information

    PRELIMINARY GATE 1 DG JOLLY 3 JOLLY 3 SEACLOUD SEACLOUD GATE 1 DG R2BF (S . 03.04) GATE 1 DG R2EF (S . 03.04) GATE 1 DG R3BF (S . 00.01) OFTWARE REV OFTWARE REV OFTWARE REV TECHNICAL INFORMATION 230V...
  • Page 3 1 - CONNECTIONS WARNING: CONNECT ALL DEVICES WHEN THE CONTROL UNIT IS SWITCHED-OFF JOLLY CLOUD ANT COM START STPD STOP COM PH1 PH2 EDGE1 24VAUX COM 24V(FL) FL(-) OPTIONAL JUMPERS UTOMATIC RECOGNITION OF THE N.C. INPUTS NOT IN USE O JUMPER IS N.C.
  • Page 4 2 - MAIN WIRINGS EXAMPLE OF EXAMPLES OF 10K PHOTOCELLS WIRINGS ANTENNA START GATE 1 DG R 2 BF GATE DG R PARTIAL START GATE DG R STOP PHOTOCELLS WIRINGS EXAMPLE OF 10K PHOTOCELL AND BUZZER WIRINGS 9 10 EXAMPLE OF SAFETY EDGE AND WARNING LAMP WIRINGS UZZER 10K P...
  • Page 5: Inputs Status

    3 - OPERATOR WIRING ON CONTROL UNIT MOTOR 1 (115V) XAMPLE = MCL - M1 CLOSING = MN - M1 NEUTRAL (WHITE) = MOP - M1 OPENING 19 - 20 = CAPACITOR MCL MN MOP CAPACITOR BLUE 230V CAPACITOR SLIDING MOTOR XAMPLE 4 - CONTROL UNIT POWER SUPPLY...
  • Page 6 6 - «START» COMMAND QUICK LEARNING ON THE TX OWER HOLD PRESSED 5 SECONDS PRESS 0 0 11111 0 EXIT STORED BUTTON 11000000 DOWN 7 - WORKING TIMES LEARNING AVE A QUALIFIED SERVICE PERSON TO CARRY OUT THE OPERATIONS IN SAFE CONDITIONS QUICK START - ONLY FOR SLIDING OPERATORS...
  • Page 7 GATE 1 DG (R2BF) - (R2EF) - (R3BF) MENU FUNCTIONS TABLE THE DESCRIBED FUNCTIONS ARE VALID FOR ALL GATE 1 DG VERSIONS, EXCEPT WHERE EXPRESSLY STATED MENU DESCRIPTION DEFAULT NOTES Italiano Italian English English 1 LANGUAGE Français French English Español Spanish Dutch Dutch...
  • Page 8 MENU DESCRIPTION DEFAULT NOTES Automatic Automatic logic - automatic reclosing enabled Open-stop-close-stop-open Step by step type 1 Open-stop-close-open Step by step type 2 Auto- 6 LOGIC matic 2 button Two buttons Safety Safety Dead man Dead man Semi-automatic logic enabled (a START command opens and another START closes the gate - automatic reclosing disabled) 7 TIMER TO CLOSE...
  • Page 9: Special Menu

    SPECIAL MENU PRESS AT THE SAME TIME FOR 5 SECONDS TO ENTER OR TO EXIT THE SPECIAL MENU THE DESCRIBED FUNCTIONS ARE VALID FOR ALL GATE 1 DG VERSIONS, EXCEPT WHERE EXPRESSLY STATED SPECIAL MENU DESCRIPTION DEFAULT NOTES Motor 1 opening torque: by increasing the torque, more strength will be required depends 28 OPENING TORQ 1...
  • Page 10 SPECIAL MENU DESCRIPTION DEFAULT NOTES adjust threshold potentiometer POTENTIOMETER intervention. This parameter self-determines during the THRESHOLD working times learning but can also be adjusted later, on OPENING 1 the condition that the set value is higher than the value depends 1000 shown in VP1 (instantaneous speed values which can be POTENTIOMETER...
  • Page 11 SPECIAL MENU DESCRIPTION DEFAULT NOTES Opening and closing The gate leaf makes an extra movement at the maximum 80 PUSHOVER torque to ensure the tightening of the gate Only closing Only opening To activate the repetition of the pushover function at a 81 PERIODICAL PUSHOVER Off distance of time adjustable from 0 to 8 hours, at hourly intervals...
  • Page 12 SPECIAL MENU DESCRIPTION DEFAULT NOTES Always AUX output always powered In cycle AUX output powered only during cycle Opening AUX output powered only during opening Closing AUX output powered only during closing In pause AUX output powered only during pause Phototest AUX output powered for safety devices testing AUX output powered only during cycle and for safety...
  • Page 13 SPECIAL MENU DESCRIPTION DEFAULT NOTES If the photocell is occupied during closing, the gate Closing reverses the movement; If the photocell is occupied during the pause, it prevents the gate reclosing If the photocell is occupied during opening or closing, it Opening and closing stops the gate movement;...
  • Page 14 SPECIAL MENU DESCRIPTION DEFAULT NOTES If the photocell is occupied during closing, the gate Closing reverses the movement; If the photocell is occupied during the pause, it prevents the gate reclosing If the photocell is occupied during opening or closing, it Opening and closing stops the gate movement;...
  • Page 15 SPECIAL MENU DESCRIPTION DEFAULT NOTES Normal Normal N.C. contact SAFETY EDGE 1 Safety edge protected by a 8K2 resistor enabled Menu available on 8K2 Double Two safety edges protected by a 8K2 resistor enabled models R2BF and R2EF only Photo 1 10K Photocell protected by a 10K resistor enabled Photo 1 10K Double Two photocells protected by a 10K resistor enabled...
  • Page 16 SPECIAL MENU DESCRIPTION DEFAULT NOTES To adjust the temperature threshold to enable the oil LOWER THRESHOLD From -20° to +50° heater (This menu is shown only if the menu 109- -10° TEMPERATURE Thermometer is set to ON) To adjust the temperature threshold to disable the oil UPPER THRESHOLD From -20°...
  • Page 17 NOTES...
  • Page 18 NOTES...
  • Page 20 SEA USA Inc. 10850 N.W. 21st - unit 160 - DORAL - MIAMI Florida (FL) 33172 Phone: ++1-305.594.1151 Toll Free: 800.689.4716 www.sea-usa.com sales@sea-usa.com...

This manual is also suitable for:

Gate 1 dg r2efGate 1 dg r3bf