Step #3: Initiate Upgrade Process - Nortel CM 100 Release Note

Nortel versalar cm 100 modems: release note
Table of Contents

Advertisement

Release Notes for the CM 100

Step #3: Initiate Upgrade Process

Software Upgrade via SNMP
Use the following procedure to upgrade a CM 100 using an SNMP
manager.
1. Select cable modem device to be upgraded.
2. Select the DocsDev MIB Object ID.
3. Select the Docs_Software MIB Object ID. The SNMP manager
4. Set the Server (docsDevSwServer) IP Address to the IP Address of the
5. Set the Filename (docsDevSWFilename) to the filename of the upgrade
Caution: All parameters must be set exactly as stated. Verify that all
previous steps are complete and accurate, especially file names and IP
Addresses. Verify that the TFTP server is ON and the loadable files are in
the TFTP server's public directory.
6. Initiate the upgrade process by setting the AdminStatus MIB
You can monitor the process if your TFTP server has a display window, or
returns status information to you. The process takes about one minute.
The modem will reset itself during this process. To verify that the software
loaded correctly, examine the SysDescr MIB object, which shows the
software revision.
1-4
displays the softwareInfo Table.
TFTP server.
software that you copied into the TFTP server's default directory. Enter
only the filename. Do not enter the full path to the TFTP server's public
directory.
(docsDevSWAdminStatus) to upgradeFromMgt.
305471-B Rev 02

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cm 100 v2.1

Table of Contents