ALLREDI MARCO 151E Operator's Manual

ALLREDI MARCO 151E Operator's Manual

Remote control switch

Advertisement

Quick Links

Before using this equipment, read, understand and follow all instructions
in the Operator's Manuals provided with this equipment. If the user and/
or assistants cannot read or understand the warnings and instructions,
the employer of the user and/or assistants must provide adequate and necessary training to ensure
proper operation and compliance with all safety procedures pertaining to this equipment. If Operator's
Manuals have been lost, please visit www.allredi-us.com, or contact Allredi at 563.324.2519 for
replacements. Failure to comply with the above warning could result in death or serious injury.
OPERATOR'S MANUAL
MARCO
®
CONTROL SWITCH
151E REMOTE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the MARCO 151E and is the answer not in the manual?

Questions and answers

Summary of Contents for ALLREDI MARCO 151E

  • Page 1 If Operator’s Manuals have been lost, please visit www.allredi-us.com, or contact Allredi at 563.324.2519 for replacements. Failure to comply with the above warning could result in death or serious injury.
  • Page 2: Company Profile

    Company Profile Allredi was formed in the early 2020, when two of the largest distributors in the blasting, coating, safety, and environmental industry, APE Companies and Marco Group International, joined forces. While the qualities both companies are known for have not changed, a lot about our business is new. New abilities. New agilities. New ways to help you win.
  • Page 3: Table Of Contents

    TABLE OF CONTENTS Company Profile ........1 Definition of Terms ....... 2 Hazard Identifications .
  • Page 4: Hazard Identifications

    HAZARD IDENTIFICATIONS Failure to comply with ANY WARNING listed below could result in death or serious injury.  OSHA sets exposure limits to protect workers from exposure to respirable crystalline silica, 29 CFR 1910.1053. Airborne dust could increase the exposure levels beyond permissible limits. Breathing dust containing silica could cause silicosis, a fatal lung disease.
  • Page 5  For equipment manufactured by entities other than Allredi, you must consult the Original Equipment Manufacturer operator’s manuals, information, training, instructions and warnings, for the proper and intended use of all equipment.
  • Page 6 HAZARD IDENTIFICATIONS Failure to comply with ANY CAUTION listed below may result in minor or moderate injury.  Static electricity can be generated by abrasive moving through the abrasive blasting hose causing a shock hazard. Prior to use, ground the abrasive blasting pot and abrasive blasting nozzle to dissipate static electricity.  High decibel noise levels are generated during the abrasive blasting process which may cause loss of hearing.
  • Page 7: Air & Abrasive Consumption Chart

    AIR & ABRASIVE CONSUMPTION CHART Failure to comply with ANY NOTICE listed below could pose a hazard to personnel or property.  See Air & Abrasive Consumption Chart for estimated abrasive consumption rates and required air flow (cubic feet per minute). Your system must meet these minimum requirements to ensure proper function and performance.
  • Page 8 “THE BIG PICTURE” Marco 151E Remote Control Switch ®...
  • Page 9: Daily Pre-Operation Checklist

    Switch Operator's Manual for applicable instructions. * Optional or alternative device. Abrasive Blasting Pot Exhaust Muffler – Inspect Abrasive Blasting Pot Ask your Allredi Representative Exhaust Muffler (24) at start and end of daily use. Replace element of Abrasive for more details.
  • Page 10: Operating Instructions

    100 feet from the abrasive blasting control systems pot. The Marco 151E Remote Control Switch manufactured by Allredi™ features a spring- ® resulting in the release of high speed abrasive assisted safety tab and control handle, providing a dual “Fail-to-Safe”...
  • Page 11: Installation

    INSTALLATION Marco 151E Remote Control Switch ® W-562 Always depressurize the entire system, disconnect all power sources and lockout/ tagout all components before any maintenance or troubleshooting is attempted. Failure to comply with the above warning could cause electrical shock and inadvertent activation of equipment resulting in death or serious injury.
  • Page 12: Maintenance

    MAINTENANCE Disassemble and Assemble Marco 151E Remote Control Switch ® W-562 Always depressurize Maintenance of the Marco 151E Remote Control Switch is limited to the daily cleaning and ® the entire system, the immediate replacement of damaged or worn parts. disconnect all power sources and lockout/ tagout all components...
  • Page 13: Disassemble And Assemble Marco ® 151E Remote

    MAINTENANCE Disassemble and Assemble Marco 151E Remote Control Switch ® Marco 151E Remote Control Switch ®...
  • Page 14: Troubleshooting

    TROUBLESHOOTING If the Marco 151E Remote Control Switch does not function properly, check the following: ® W-562 Always depressurize the entire system, SYMPTOM (Cause) ACTION disconnect all power sources and lockout/ Remote Control Switch will not Handle is not making contact with Micro tagout all components activate when Remote Control Handle Switch.
  • Page 15: Limited Warranty

    LIMITED WARRANTY ADDITIONAL TECHNICAL DATA Seller warrants to the original purchaser that the Product covered by this Limited Warranty will remain free from defects in workmanship or material under normal commercial use and service for a period of one year from the The associations listed date of shipment to the original Purchaser.
  • Page 16 251.338.7525 Winnipeg, Manitoba 281.930.0905 204.256.3324 800-252-7848 / WWW.ALLREDI-US.COM Allredi™ and Marco are registered trademarks of Allredi, LLC. Literature #1090063_1/16/23 ® Part #1090063_05/11/16 All other brand names or marks are used for identification purposes and are trademarks of their respective owners.

Table of Contents