Questions and answers

Summary of Contents for Neumo BioControl

  • Page 1 Installation and Maintenance Instructions BioControl® - Housing including Components PN16 -10°C to +200°C Content: 1. Intended Usage Agreement 2. Field of Application 3. Installation 4. Maintenance 5. Notes and Recommendations 6. Construction 7. Spare Parts 8. Possible Hazards 9. Exclusion of liability Page 1 of 8 Release 02.12.2019 / Dep.
  • Page 2 The weld-on ends of the housing and the pipe connections have to be prepared for the I-seam according to DIN EN ISO 9692-1 Please ensure that the sealing edges of the „BioControl®“ housing are not damaged and cannot be damaged during the operations with the parts.
  • Page 3 DANGER The pipe work may contain corrosive cleansing media residues. Therefore, the pipe sec- tion for the BioControl® housing has to be rinsed thoroughly prior to assembly. Welding the housing: WIG oder WIG-Orbital. Please adhere to the corresponding process regulations and cer-...
  • Page 4 Table 1: Friction recommended tightening torque (t) Coefficient 0,10 14,5 30,0 0,12 16,3 33,0 0,14 17,8 36,0 0,16 19,3 39,0 0,18 20,4 41,0 0,20 21,5 44,0 0,30 10,4 25,5 51,0 0,40 11,3 27,6 56,0 Technical information for the tightening torques for screws: Since different friction coefficients can appear in practice the torques quoted in table 1 can only be adopted as reference values! The torqueses apply for screws EN 24014 / 24017, strength category 70 at room tem-...
  • Page 5 DANGER The pipe work may contain corrosive cleansing media residues. Therefore, the pipe sec- tion for the BioControl® housing has to be rinsed thoroughly prior to assembly. Close, rinse and secure the pipe section of the BioControl® housing Remove the blind cover or measuring device carefully from the housing seat.
  • Page 6 5. Advice and Recommendations: By default, the NEUMO „BioControl®“ components are undetachably marked for a no- minal pressure of 16 bar. Should they be applied for higher pressures, please include the following data in your inquiry to the company NEUMO The required pressure = ..
  • Page 7 The responsibility for draining is generally the responsibility of the plant manufacturer and the end customer. Warranty: In accordance with the general terms and conditions of NEUMO GmbH + Co. KG www.neumo.de 9. Exclusion of liability: In accordance with the general terms and conditions of NEUMO GmbH + Co. KG www.neumo.de...
  • Page 8 Page 8 of 8 Release 02.12.2019 / Dep. QMB/ Rev 11 FB_084_Installation and Maintenance Instructions_BioControl Components-V3.doc...