Safety Instructions - Schuch nD8700 Series Operating Instructions Manual

Explosion-proof led-floodlight / plane surface floodlightexplosion-proof led-floodlight / plane surface floodlight
Table of Contents

Advertisement

1. Safety Instructions

Mounting and installation must be done in accordance with the respective regulations.
The light fitting must be protected against overvoltage, overcurrent, short circuits and other
electrical failures.
The light fitting must be operated in an undamaged condition only.
The light fitting may only be opened if it has been disconnected from the mains supply completely.
It is allowed to open the light fitting in a non-explosive (non hazardous) atmosphere only.
The non-stationary use of the light fitting as well as any other inappropriate usage is prohibited.
The operation of the light fitting is allowed within its assessment thresholds only.
In regard to the minimum and maximum admissible ambient temperature potential sources of cold
and heat (e.g. direct heat or solar radiation, cooling units) have to be considered.
If the light fitting is subject to a special application that is influenced chemically, mechanically,
thermically or electrically or if the light fitting will be subject to any kind of vibrations, it is highly
recommended to consult the Adolf Schuch GmbH before starting the installation.
Every structural modification will cause dangerous situations and consequently the certification of
this light fitting will be null and void.
The light fitting is not allowed to be installed in process areas where strong electrical fields
may occur (i.e. HV Sparkling Electrodes or Particle Streams). Reason is to avoid any
electrostatic charge of the light fitting itself.
The filling level of the connection cable should be quite high for avoiding any air penetrating the
inside of the light fitting through the cable.
The stated minimum distance between light fitting and illuminated objects must be observed.
Applying an explosion-proof breathing gland for pressure compensation is not allowed.
Replace damaged parts by original spare parts from the Adolf Schuch GmbH only.
The LED-modules of this light fitting must be replaced by A. Schuch GmbH, by a service technician
who is instructed from Schuch or by any other person with equivalent qualification only.
Special versions with seawater-resistant paintwork:
Caution - Risk of electrostatic discharge!
Fitting to be cleaned with damp cloth only!
In areas with risk of accidental electrostatic charge (e.g. by passing by) the light fitting must
be protected by appropriate measures.
10/2022
L-01424-4-14
2

Advertisement