Сочи Череповец (473)204-51-73 (4712)77-13-04 (3532)37-68-04 (862)225-72-31 (8202)49-02-64 Екатеринбург Липецк Пенза Ставрополь Ярославль (343)384-55-89 (4742)52-20-81 (8412)22-31-16 (8652)20-65-13 (4852)69-52-93 Иваново (4932)77-34-06 Киргизия Россия Казахстан (996)312-96-26-47 (495)268-04-70 (772)734-952-31 https://lamborghini.nt-rt.ru/ || hgc@nt-rt.ru KYRA D 30 SI UNIT COND INSTRUCTIONS FOR USE, INSTALLATION AND MAINTENANCE...
Page 2
INDEX 1. GENERAL INFORMATION ......................36 2. OPERATING INSTRUCTIONS ....................36 2.1 Introduction ..........................36 2.2 Control panel .......................... 36 2.3 Lighting and turning off ......................37 2.4 Adjustments ..........................37 3. INSTALLATION OF THE APPLIANCE ..................38 3.1 General Instructions ....................... 38 3.2 Place of installation ........................
(details 12 and 13 - fi g.1). Thank you very much for choosing KYRA D 30 SI UNIT COND, a LAMBORGHINI The DHW graduation marks (detail 11 - fi g.1) light up as the DHW sensor tempera- standing boiler with advanced design, state-of-the-art technology, high reliability and turereaches the set value.
Page 4
KYRA D 30 SI UNIT COND 2.3 Lighting and turning off The display activates the Summer symbol (detail 27 - fi g.1): the boiler will only deliv- erdomestic hot water. The antifreeze system remains activated. Boiler not electrically powered To deactivate the Summer mode, press the summer/winter button (part. 6 - fi g.1) againfor 1 second.
KYRA D 30 SI UNIT COND fi g.16 - Low system pressure fault fi g.13 - Curve parallel offset Once the system pressure is restored, the boiler will activate the Press the mode button (detail 10 - fi g.1) again to exit parallel curve adjustment 120-secondair venting cycle indicated on the display by FH.
KYRA D 30 SI UNIT COND Light indicators Characteristic Signalling Adjustment mode LED indicator curve • In normal operation, the LED lights up green Constant speed • LED on/fl ashing in case of a fault Indication of selected adjustment mode Δp-v, Δp-c and constant speed...
Page 7
KYRA D 30 SI UNIT COND The oil feed circuit must be made according to one of the following diagrams, with- ATTENTION out exceeding the pipe lengths (LMAX) given in the table. In case of a power failure, all settings and displays remain stored.
“HAR H05 VV-F” 3x0.75mm2 cable with a maximum outside diameter of After-Sales Technical Service. 8 mm. LAMBORGHINI declines any liability for damage and/or injury caused by unquali- Room thermostat (optional)(remove the existing bridge terminals 17-18) fi ed and un-authorised persons tampering with the unit.
Page 9
KYRA D 30 SI UNIT COND Pump pressure adjustment Position of electrodes - baffl e The pump is factory-set to 14 bar. Use an oil bath gauge to check the pressure. The After fi tting the nozzle, check correct positioning of the electrodes and baffl e, ac- pressure can be adjusted between 11 and 14 bar.
Page 10
KYRA D 30 SI UNIT COND Checks to be made at fi rst lighting, and after all maintenance operations Index Description Range Default involving disconnection from the systems or an operation on safety de- (23) No function vices or partsof the boiler:...
Page 11
KYRA D 30 SI UNIT COND Starting without pre-heater Accessing the electrode and nozzle Flame present • Disconnect the transformer electrode cables and remove the photoresistance 1, Normal operation andt he union 2 connecting the oil pipe to line 3 of the nozzle. Loosen the screws Adjustment stop (TA-TC) 4 andpull out the nozzle-baffl...
Page 12
KYRA D 30 SI UNIT COND Circulating pump Table. 3 - List of faults Faults must only be repaired by qualifi ed specialist technicians, work on electrical Fault Fault Possible cause Cure connections must only be carried out by qualifi ed specialist electricians.
KYRA D 30 SI UNIT COND Fault Fault Possible cause Cure code Faulty mains fre- Check the electrical Electric mains trouble quency system Pressure too low Fill the system Incorrect system water pressure Sensor damaged Check the sensor Probe damaged or wiring...
Page 14
KYRA D 30 SI UNIT COND 5.2 Water circuit 5.3 Diagrams Circulating pumps Head/Pressure loss - Circulating pump head with setting at “fi xed speed”. fi g.40 Boiler pressure losses 1 - 2 – 3 Circulating pump speed fi g.39 - Water circuit - Circulating pump head with setting at “proportional head”.
Page 15
KYRA D 30 SI UNIT COND 5.4 Technical data table Model KYRA D 30 SI UNIT COND Max. heating capacity 29,3 Min. heating capacity 16,0 Max. heat output in heating (80/60) 28,5 Min. heat output in heating (80/60) 15,6 Max. heat output in heating (50/30) 30,0 Min.
Page 16
KYRA D 30 SI UNIT COND ErP product fi che MODEL: KYRA D 30 SI UNIT COND Trademark: LAMBORGHINI Condensing boiler: SÍ Low-temperature boiler (**): NO B1 Boiler: NO Combination heater: SÍ Cogeneration space heater: NO Item Symbol Unit Value Seasonal space heating energy effi...
Page 17
KYRA D 30 SI UNIT COND 5.5 Wiring diagram fi g.42 - Wiring diagram Heating circulating pump Flow switch DHW temperature sensor (optional) TR Ignition transformer Room thermostat (optional) PR Preheater 138 External probe (optional) FR Photoresistance 139 Remote Timer Control (optional)