RJ-11/12 cables may have
2 connection cables, LED 3 and 4 must light.
4 connection cables, LED 2, 3, 4 and 5 must light.
6 connection cables, LED 1, 2, 3, 4, 5 and 6 must light.
The Numbered LEDs don't indicate that a GOOD connection
exists, only that a connection exists. If the Short or Cross LEDs
are Lit, there is a fault in the cable.
Connected LED/ 3Beepers/ Short LED/ Numbered LEDs
If the Connected LED lights, the Beeper emits 3 beeps, and the
Short LED lights, the cable has a fault. The Numbered LEDs
indicate the location of a short.
Note: In the Short mode, the Numbered LEDs only indicated the
location of the shorts. The other connections in the cable are not
indicated. If more than 3 numbered LEDs light, there may be
multiple shorts in the cable.
Connected LED/ 2 Beepers/ Cross LED/ Numbered LEDs
If the Connected LED lights, the Beeper emits 2 beeps, and the
Cross LED lights, the cable has a fault.
Notes: In the Cross-mode, the Number LEDs indicate
connections but do not indicate the location of the cross.
RJ-11 cables used for telephone connections are often
crossed. Even new cables are often crossed. This seldom
affects the performance of standard analog telephone lines
(POTS). Digital telephone lines and old touch-tone phones
may be polarity sensitive, so a crossed cable may prevent
them from working properly.
Maintenance:
4 in 1 Cable Tester is a precision test instrument and, when
used as described in this manual, should not require
maintenance. There are no internal adjustments. Calibration is
not required.
To clean outside of the tester, use a cloth dampened with a mild
detergent solution. Do not use any abrasive cleansers, or
chemical solvents that may damage the tester.
5
Testing Patch cables:
"Patch" cables have both ends accessible at the same location.
Usually, these cables are less than 25ft in length, and are
not installed in a wall orceiling.Since both ends are accessible,
one end one be plugged into the 4 in 1 Main unit,and the
other into the remote unit. It is unecessary to remove the
remote unit from its docked position on the Main unit.
Testing Installed cables:
If the two ends of testing cable are not in the same location, the
Remote can be detached from the Main unit. Once detached, the
Remote can be attached to one end a cable, and the Main unit
attached to the other end of the cable.
Performing the Test:
Once the Remote and Main unit are attached to the ends of
the cable, testing may begin, simply press and release the
Test Button on the Main unit, observe the LED indicators,
and note the "beep" sound that comes from the Main unit.
Interpreting the Results:
Power LED:
The Power LED should light whenever the "Test" Button is
pressed and released. It will be on for a minimum of 5 seconds.
If the power LED does not light, replace the battery.
Low Battery LED:
The low Battery LED should not light . If it does, replace the
battery.
No connection LED/Single Beep:
If the Remote is not connected to the Main unit with a cable, or
the cable has no intact conductors, the No Connection LED will
light and the Beeper will sound Once.
Note: When testing an RJ-45 STP cable. The S/G must light.
When testing an RJ-45 UTP cable. The S/G LED must not light.
The 4 in 1 is intended to test complete cables. It may not find
faults in cables that are intentionally incomplete. For example,
the standard EIA/TIA 568 RJ-45 terminated Ethernet cable is
expected to contain 8 conductors. If only 4 conductors are used
between the RJ-45 connectors, the 4 in 1 may not properly
identify the faults.
4
User's Manual
4 IN 1
CABLE TESTER
TESTED UPTO
1500 FT.
(Do not use until you read this manual carefully)
BTM2Y
CABLE TESTER
YOUR EXCELLENT HELPER IN CABLE TEST
PM:BM530601-0
WWW.BAYLAN.COM
Need help?
Do you have a question about the BTM2Y and is the answer not in the manual?
Questions and answers