Table of Contents Chapters Sections Safety Instructions Safety Instructions Introduction Product View Specifications Product Specifications Installation Before Installation Additional Tools and Parts Charging Station Installation Disassemble Logo Cover Secure Mounting Bracket Fasten the Charging Station Input Power Cord Installation Choosing Conduit Attaching Compression Lugs Electrical Wiring Set Operating Current...
Safety Instructions This guide contains instructions and warnings should not attempt to fix, repair, or that must be followed when installing and adjust it. using the Electric Vehicle Supply Equipment (EVSE). Before installing or using the EVSE, Always turn off the input power before read this entire guide including the WARNING repairing or maintaining this equipment.
Page 5
without written approval may void the user’s WARNING: RISK OF ELECTRIC SHOCK authority to operate this equipment. Follow the basic precautions when using Industry Canada statement: electrical products. Read all the instructions before using this equipment. This equipment complies with ISED’s license- exempt Radio Standards Specifications (RSS).
Remark The box should consist of the following Lucid Ensure that the components: Connected variant in the box 1. Lucid Connected Home Charging Home Charging is accurate per the Station and Cable Station OR use type. LTE Lucid variant is only for...
Product Specifications Item Lucid Connected Home Charging Station, NA Lucid Connected Home Charging Station, LTE, Application Residential Commercial Voltage 208 - 240VAC, Single Phase 208 - 240VAC, Single Phase Frequency 60Hz 60Hz Current Adjustable up to 80A Adjustable up to 80A...
Page 10
Item Lucid Connected Home Charging Station, NA Lucid Connected Home Charging Station, LTE, Certifications UL 1998/2231/2594 UL 1998/2231/2594 FCC Part 15B FCC Part 15B FCC Part 15.247 (WLAN 2.4GHz) FCC Part 15.247 (WLAN 2.4GHz) FCC Part 15.225 (RFID 13.56MHz) FCC Part 22/24/27...
Before Installation Safety Check Check the exterior packaging for signs of mishandling and ensure the equipment was not damaged during shipping. Before connecting the product to the power supply, check that the power supply voltage and current rating corresponds with the power supply details shown on the product rating label.
Additional Tools and Parts Tool Size Screw Appropriate for wall/pedestal material Compression Lugs Used to land branch circuit wires on terminal block Philips Screwdriver Torx Screwdriver T20H (included in the box) Torque Wrench >40 lb-in Installation...
Charging Station Installation Disassemble Logo Cover 1. Remove 2x M4 screw with T20H bit. 4. Remove 2x M4 screw with T20H bit, and remove rear mounting bracket. 2. Slide logo cover up and remove by pulling from charging station housing. Secure Mounting Bracket Secure the main body mounting bracket to the wall with the appropriate screw.
1. Fasten mounting bracket. 4-Hole Mounting Fasten the Charging Station Fasten the charging station onto mounting bracket. 2-Hole Mounting 1. If the user is planning to use a “Top or back input” and “Ethernet cable”, drill the appropriate holes before mounting to any surface.
Page 16
3. Place the charging station on the mounting bracket. 4. Fasten the charging station on the mounting bracket by tightening the 2x M4 screws. Installation...
Choose the appropriate conductors in and national electrical codes, and standards. accordance with all applicable, state, local, and national electric codes and standards. Model Terminal Conductor Rating Lucid Connected L1, L2 2 AWG 90 º Home Charging Copper 8 AWG Station...
Page 18
Conduit Torque 1 " 35 kgf.cm 30.36 lb-in 6. Remove the cable tie and connect the jumper wire. Then, reassemble the top cover, and fasten the M4 screw. 3. Fasten the copper wire on the corresponding terminal block. The wiring instruction is printed in front of the terminal block (L1/L2/G).
To set the operating current, configure SW1, SW2, SW3, SW4 from DIP switch If the Lucid Connected Home Charging Station is installed on a breaker smaller than 100A, the dip switches support de-rating the station to match said breaker. This same table below can also be found on a sticker inside the station for ease of use.
Page 20
Item Continuous Output Configure Circuit Breaker Size** DOWN DOWN DOWN DOWN DOWN 80A (Default) 100A DOWN Installation...
Charging Status Indicators The Lucid Connected Home Charging Station's LED status indicators illuminate the vertically- oriented LUCID logo on the front cover of the station. Color and Pattern Intensity Definitions Action White Solid Plugged In, Not Charging When battery is supplying...
Page 23
Color and Pattern Intensity Definitions Action Orange Solid Battery Board Fault Ask an electriction to: Replace the battery board if needed Troubleshoot: If problem presists contact Lucid customer care. Operations...
Have the following ready before connecting c. This will then load the Lucid Web your station to the internet. Connecting your Configurator login screen. Enter station to the internet should be completed...
Page 25
7. Select the Cloud tab under Setup, and ensure Lucid Cloud is selected. The Customer’s Lucid ID is displayed. Click Apply. Note: This must be the same Lucid ID email address that the customer used to create their Lucid account for the vehicle and mobile app.
Additional Power-On Operations Authorization (For LTE Model only) station will automatically retry charging three times. Before charging an electric vehicle, the LTE Power Outage Recovery model includes an RFID reader, which must be authorized to begin the charging session. This RFID reader is available on the right Please allow up to 15 minutes after side of the unit, showing the RFID symbol for power resumes before the station will be...
Who is the Warrantor? such as chips, dents, cracks and scratches. Lucid USA, Inc. is the warrantor in the United States and Lucid Motors Canada ULC is the Abuse and/or misuse of the Lucid Home warrantor in Canada (collectively "Lucid”).
Page 28
Limited lodging expenses, and incidental charges like Warranty. phone, fax, or postal expenses, even if Lucid is advised of the possibility that such damages Limitations on Liability are reasonably foreseeable...
General Care The exterior of the charging station is designed to be water and dust resistant per NEMA 3R rating'. To ensure proper maintenance of the charging station, follow these guidelines: When cleaning, do not direct streams of water at the unit despite the enclosure's water resistance.
Customer Support If the power cable or the charging plug is damaged, please contact Customer Support. 1-888-99 LUCID (1-888-995-8243) customercare@lucidmotors.com Operations...
Need help?
Do you have a question about the Connected Home Charging Station and is the answer not in the manual?
Questions and answers