HBM453 DISPLAY & BLOW-BY METER SYSTEM
J-TEC flow meters operate on the principle of vortex shedding.
A small strut inside the flow tube creates a Karman vortex street
and the vortex formation is sensed by means of an ultrasonic
beam directed across the tube. The flow meter electronics uses
the vortex frequency to determine the flow rate.
The J-TEC HBM453 is a two piece design, consisting of a
handheld enclosure with a display, battery power compartment,
interface cable and a separate flow measurement body.
J-TEC flow meters have a 12-month warranty period.
SPECIFICATIONS
Measured:
Flow rate measured:
Operating (GAS) temperature:
Operating pressure:
Accuracy:
Repeatability:
Line Size:
Construction:
Interface Cable Length:
Ambient temperature limits:
Response Time:
Power Source:
Display:
*(not approved for explosive gas mixtures, except for crankcase vapors)
5005 Blairs Forest Lane NE, Suite L • Cedar Rapids, IA 52402
phone 319-393-5200 • fax 319-393-5211
Operator's Manual
for the
Air or low pressure gas*
0.8 to 16.0 ACFM (Actual Cubic Feet per Minute)
0º to 200ºF
-5 TO +5 PSIG
± 3% full scale
± 1.0% of reading
5/8" ID
Ryton® (PPS) and ABS plastic
6 feet
-20º to 150ºF
100 milliseconds
4 AA batteries (use alkaline or NiMH rechargeable)
Operation time is approximately 40 hours
on fresh or fully charged batteries
8 characters x 2 lines: Viewing area 1.5" x 0.6"
Top line is the flow
Bottom line is the engineering units (ACFM).