Stratus U773 Manual

12-port fibre channel switch replacement

Advertisement

Quick Links

U773 12-Port Fibre Channel Switch Replacement
Stratus Technologies
R002S-00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the U773 and is the answer not in the manual?

Questions and answers

Summary of Contents for Stratus U773

  • Page 1 U773 12-Port Fibre Channel Switch Replacement Stratus Technologies R002S-00...
  • Page 2 Software described in Stratus documents (a) is the property of Stratus Technologies Bermuda, Ltd. or the third party, (b) is furnished only under license, and (c) may be copied or used only as expressly permitted under the terms of the license.
  • Page 3: Table Of Contents

    Contents Preface 1. Replacing a U773 12-Port Fibre Channel Switch The U773 12-Port Fibre Channel Switch Replacing a Switch Secured Directly to an Emulex Tray Replacing a Switch Secured by the AK-000576 Kit 1-13 Contents...
  • Page 4 Figure 1-7. Securing the Tray in the Cabinet Figure 1-8. Securing the Nut Plate to the Rail and Tray 1-10 Figure 1-9. Installing the Bracket 1-11 Figure 1-10. Securing the Face Plate 1-12 U773 12-Port Fibre Channel Switch Replacement (R993)
  • Page 5: Preface

    Preface The U773 12-Port Fibre Channel Switch Replacement (R002S) documents the removal and replacement of a U773 12-Port Fibre Channel Switch in VOS ftServer V100, V200, V400, V250, V300, V500, and V502 systems. This document is intended for service personnel who service V Series systems with U773 Fibre Channel switches in the field.
  • Page 6 If you are unable to resolve your questions with the help available at these online sites, and the ftServer system is covered by a service agreement, please contact the Stratus Customer Assistance Center (CAC) or your authorized Stratus service representative.
  • Page 7 StrataDOC Web Site Feedback form. • By email to Comments@stratus.com. If it is possible, please include specific information about the documentation on which you are commenting: – For a printed document or a document in PDF format, include the title and part number from the Notice page and the page numbers.
  • Page 8 Preface viii U773 12-Port Fibre Channel Switch Replacement (R002S)
  • Page 9: Replacing A U773 12-Port Fibre Channel Switch

    The U773 12-Port Fibre Channel Switch U773 fibre channel switches are housed in an Emulex tray and secured to the tray by a Stratus-supplied AK-000576 (revision 001) mounting hardware kit. The bracket in the kit allows for the removal of either switch while the system is online. When replacing a U773 switch that is not secured by an AK-000576 kit, you must take the system off-line because you must remove both switches and the tray.
  • Page 10: Replacing A Switch Secured Directly To An Emulex Tray

    Replacing a Switch Secured Directly to an Emulex Tray Tool needed: #2 Phillips-head screw driver. Since you must shut down the system to replace a U773 fibre channel switch that is mounted in an Emulex tray, schedule system downtime before performing this procedure.
  • Page 11: Figure 1-1. Labeling The Cables (D916, Ftscalable Storage, Rear View)

    RAID Array 1 CACHE Activity STATUS Service Controller B CACHE Activity STATUS Maint Switch S1 Maint Switch S0 Service Controller A RAID Array 2 CACHE Activity STATUS Service Controller B CACHE Activity STATUS wom024d Replacing a U773 12-Port Fibre Channel Switch...
  • Page 12: Figure 1-2. Labeling The Cables (D910, Fc Jbod, Rear View)

    Figure 1-2. Labeling the Cables (D910, FC JBOD, Rear View) Maint Switch Maint Switch FC Switch A2 FC Switch B2 C2 D2 C2 D2 JBOD Array 1 Enclosure 4 Enclosure 3 Enclosure 2 Enclosure 1 wom037c U773 12-Port Fibre Channel Switch Replacement (R993)
  • Page 13: Figure 1-3. Rear Brackets With Screws And Nut Plates

    Repeat this step for the corresponding screws and nut plate on the other side of the system. Figure 1-3. Rear Brackets with Screws and Nut Plates vos199a Screws (8) Nut plate (2) Replacing a U773 12-Port Fibre Channel Switch...
  • Page 14: Figure 1-4. Removing The Tray From The Front Rails

    6. At the front of the system, remove the four screws (Figure 1-4) that secure the tray to the front rails and pull the tray with the two switches out of the cabinet. Figure 1-4. Removing the Tray from the Front Rails vos200a U773 12-Port Fibre Channel Switch Replacement (R993)
  • Page 15: Figure 1-5. Removing The Eight Screws From Underside Of Tray

    The U773 12-Port Fibre Channel Switch 7. Remove the eight screws from the underside of the tray (see Figure 1-5). Figure 1-5. Removing the Eight Screws from Underside of Tray vos201a Replacing a U773 12-Port Fibre Channel Switch...
  • Page 16: Figure 1-6. Ak-000576 Kit

    Use only the top and bottom screw holes on each side to secure the four screws, as shown in Figure 1-7. U773 12-Port Fibre Channel Switch Replacement (R993)
  • Page 17: Figure 1-7. Securing The Tray In The Cabinet

    The U773 12-Port Fibre Channel Switch Figure 1-7. Securing the Tray in the Cabinet vos200c Replacing a U773 12-Port Fibre Channel Switch...
  • Page 18: Figure 1-8. Securing The Nut Plate To The Rail And Tray

    Repeat this step in the corresponding part of the other side of the tray. Figure 1-8. Securing the Nut Plate to the Rail and Tray vos199b Nut plate Back end of tray Screws (4) 1-10 U773 12-Port Fibre Channel Switch Replacement (R993)
  • Page 19: Figure 1-9. Installing The Bracket

    Figure 1-9. Installing the Bracket vos199c Bracket Screws (4) d. Install the good switch and the replacement switch into the upgraded tray, and push them into the cabinet until they are seated into the rear bracket. Replacing a U773 12-Port Fibre Channel Switch 1-11...
  • Page 20: Figure 1-10. Securing The Face Plate

    Figure 1-10. Securing the Face Plate vos200b 10. Reconnect the Ethernet and Fibre Channel cables to the U773 fibre channel switches according to the configuration you noted in step 2. 11. Power up the ftServer system and then connect the AC power cords to both switches.
  • Page 21: Replacing A Switch Secured By The Ak-000576 Kit

    Tool needed: #2 Phillips-head screw driver. 1. Remove the AC power cord from the rear of the failed U773 fibre channel switch. C A U T I O N Be sure the partner switch remains in service, otherwise the system could experience serious data loss.
  • Page 22 13. Verify that all devices come back into service, as follows: • Verify that no errors were reported during the boot process. • Use the analyze_system request list_boards to make sure no unexpected fault-codes were registered. 1-14 U773 12-Port Fibre Channel Switch Replacement (R993)