  • Page 1 Installation & Cabling Base Stations Edition 3.2 Confidential GDC-004/68...
  • Page 2 Information as well as drawings and specifications contained in this document are subject to change without prior notice. All trademarks and copyrights mentioned herein are the property of INTRACOM S.A. TELECOM SOLUTIONS and/or their respective owners. Any rights not expressly granted herein are reserved.
  • Page 3 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Document Revision History Revisions This page shows the main changes effected in relation to the previous edition of the WiBAS / WiBAS G5 Base Station Installation & Cabling manual.
  • Page 4 (Page intentionally left blank)
  • Page 5 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Equipment Disposal Disposal of old electrical and electronic equipment (applicable through the European Union and other European countries with separate waste collection systems). This symbol, found on this product and any of its parts or on its operating instructions or on its packaging, indicates that electrical and electronic equipment may not be disposed of as unsorted municipal waste.
  • Page 6 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Statement: Information to the User Class B equipment WiBAS G5 micro-BS and EN 55022 / EN 55032: evo-BS This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
  • Page 7 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Statement: Information to the User , Continued ICES-003/NMB-003: Statement: Information to the User WiBAS G5 ICES-003/NMB-003: Déclaration : Informations à l'utilisateur micro-BS and evo-BS, continued ICES-003: This Class B digital apparatus complies with Canadian ICES- 003.
  • Page 8 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Statement: Information to the User , Continued Class A equipment OSDR and WiBAS G5 dual-BS EN 55022 / EN 55032: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
  • Page 9 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Statement: Information to the User , Continued Class B equipment PONE-OD-DC EN 55022 / EN 55032: This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instruction manual, may cause harmful interference to radio communications.
  • Page 10 The full text of the EU declaration of conformity is available at the following URL: http://emc.intracom-telecom.com/en/start.htm Δήλωση Συμμόρφωσης Με την παρούσα, η Intracom Α.Ε. Τηλεπικοινωνιακών Λύσεων δηλώνει ότι Ελληνικά το προϊόν WiBAS συμμορφώνεται με τις απαιτήσεις της οδηγίας Ραδιοεξοπλισμού 2014/53/ΕΕ, Οικολογικού Σχεδιασμού 2009/125/EΚ, 2017/1369/ΕΕ, οδηγίας...
  • Page 11: Table Of Contents

    WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Table of Contents 1. Introduction .......................... 14 About this Document ......................14 Safety Precautions ......................16 Radio Units and Antennas Compatibility Matrix ..............24 2. Materials ..........................25 3.
  • Page 12 Table of Contents Appendix A - Installing Power Injectors................215 POE-AC112-ID / POE-AC75-ID / POE-ID-AC72 / POE-AC60-ID / POE-AC56-IDH ..216 PONE-OD67-AC ....................... 224 PONE-OD-DC ........................231 POE-HP-OD67-DC ......................241 POE-HP-OD-AC ........................ 245 Appendix B – Terminating Cables ..................248 Ethernet (SF/UTP) ......................
  • Page 13 (Page intentionally left blank)
  • Page 14: Introduction

     WiBAS Product Catalog.  WiBAS Startup & Commissioning.  OmniBAS IDU Installation.  Lightning & Surge Protection for Intracom Telecom Radios – Installation Practices.  Lightning & Surge Protector (LSP) Datasheet. Continued on next page Also available in PtP mode.
  • Page 15 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 About this Document , Continued Conventions This document applies to the following conventions:  Arial Bold blue fonts are used for order codes.  Arial Blue underline fonts are used for document references.
  • Page 16: Safety Precautions

    The above mentioned European Directive provides the reference levels (limits) for assessment of the human exposure to electromagnetic fields based on health effects. European Union, FCC (US) and Industry Canada Reference Levels for microwave frequencies applied to INTRACOM Telecom equipment are given in the following table (Table...
  • Page 17 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Safety Precautions , Continued RF exposure RF Exposure General Guidelines for equipment installation assessment, As a general rule it is expected that the highest level of emission would be continued in line of sight and in close vicinity of the antenna.
  • Page 18 1. Introduction Safety Precautions , Continued RF exposure assessment, Product WiBAS G5 evo-BS 24 GHz continued Antenna Type Omni Antenna Diameter (m) 0.24 0.24 0.212 Antenna Gain (dBi) 14.8 Compliance Boundary (m) General Public 0.20 0.20 0.10 Occupational 0.10 0.10 0.10 Product WiBAS...
  • Page 19 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Safety Precautions , Continued RF exposure RF Radiation Safety Information assessment, This equipment complies with: continued Cet équipement est conforme:  ISED RSS-102  FCC title 47 part 1.1310 ...
  • Page 20  INTRACOM S.A. TELECOM SOLUTIONS and its resellers or distributors are not liable for injury, damage or violation of regulations associated with the installation of outdoor units, antennas or any other accessory related to the radios.
  • Page 21 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Safety Precautions , Continued Working on the Building’s Roof During stormy weather, do not perform any mechanical assembling or antenna installation / alignment works on the building’s roof. The metal structure of towers / masts is prone to lightning.
  • Page 22 1. Introduction Safety Precautions , Continued Local power Source  AC:  Safety requirements require a single pole circuit-breaker to be employed between the local AC power source and power injector.  The circuit breaker must disconnect the mains phase of the AC power source.
  • Page 23 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Safety Precautions , Continued Power Injector Ethernet cable: Connect the OUT receptacle of power injector to the proper receptacle of the radio unit, as described in this manual. Do not connect the power injector’s OUT receptacle to network switches / routers / laptops.
  • Page 24: Radio Units And Antennas Compatibility Matrix

    1. Introduction Radio Units and Antennas Compatibility Matrix WiBAS solution provides high flexibility, through a wide variety of compact Base Station radio units combined with multiple antenna options facilitating demanding coverage scenarios. The following table presents a compatibility matrix between the radio units form factors and the available antennas.
  • Page 25: Materials

    WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 2. Materials Scope This chapter describes the installation materials of the following wireless equipment:  WiBAS OSDR-HUB  WiBAS G5 micro-BS  WiBAS G5 evo-BS  WiBAS G5 dual-BS For each material there is an extensive packing list description to the respective installation procedure.
  • Page 26 2. Materials Materials , Continued Antennas One of the following antennas, depending on site-specific RF planning requirements:  WiBAS OSDR-HUB integrated radio antenna, 10.5 GHz, 90° sectorized, horizontal polarization. Pole mounting kit is included (BRA-1090H-I).  WiBAS OSDR-HUB integrated radio antenna, 10.5 GHz, 90° sectorized, vertical polarization.
  • Page 27 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Materials , Continued Antenna One of the following antenna adaptation kits, depending on site-specific adaptation kits antenna requirements:  Antenna adaptation kit for 26 GHz (OSDR26-360-ANT-ADAPT-KIT).  Antenna adaptation kit for 28 GHz (OSDR28-360-ANT-ADAPT-KIT). Pole mounting One of the following pole mounting kits, based on site-specific mounting kit kits...
  • Page 28 2. Materials Materials , Continued Power One of the following power injectors, depending on site-specific powering injectors requirements:  AC POE injector, indoor, 56 watt (POE-AC56-IDH).  AC POE injector, indoor, 60 watt (POE-AC60-ID).  AC PONE injector, outdoor, 67 watt (PONE-OD67-AC). ...
  • Page 29 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Materials , Continued Cables One of the following cables, depending on site-specific cabling requirements:  Ethernet cable, shielded, Cat5E (SF/UTP) (ETH-CAB-SFTP).  AC power supply cable - 3 x 0.75 mm (AC-PWR-CAB).
  • Page 30 2. Materials Materials , Continued SFPs One of the following SFP, depending on site-specific traffic requirements:  Electrical SFP for 10/100/1000 Base-T operation (SFP-ELGFE-IN).  Optical SFP, multi-mode, up to 500 m, 1.25 Gbit/s, 850 nm (SFP-MM-500M).  Optical SFP, single mode, up to 10 Km, 1.25 Gbit/s, 1310 nm (SFP-SM-10KM).
  • Page 31 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Materials , Continued Others One of the following items, depending on site-specific installation requirements:  Shielded RJ-45 connector for Ethernet cable Cat5E industrial, (ETH-CAB-SFTP) termination.  DC power supply connector, 2 sockets, screw type cable terminals, IP67, UV rated, industrial (UL-ST-CONN-SCR-DC).
  • Page 32: Before Starting The Installation

    3. Before Starting the Installation 3. Before Starting the Installation Scope This chapter describes all the prerequisites that must be considered prior to installing the following wireless equipment:  WiBAS OSDR-HUB  WiBAS G5 micro-BS  WiBAS G5 evo-BS  WiBAS G5 dual-BS...
  • Page 33: Radio Unit Connection Points

    WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 3.1. Radio Unit Connection Points Introduction This section describes all the available connection points of the following wireless equipment:  WiBAS OSDR-HUB  WiBAS G5 micro-BS  WiBAS G5 evo-BS ...
  • Page 34 3. Before Starting the Installation WiBAS OSDR-HUB , Continued Label Description Product description. Frequency band. OSDR determination as Low or High in the link pair. Duplex spacing (MHz). Sub-band (01, 02). Transmit frequencies. Receive frequencies. Continued on next page...
  • Page 35 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 WiBAS OSDR-HUB , Continued Other points Marking Description Anchor point. To fit lanyard for lifting to the pole. Wave guide flange. To install antenna feeder. Latches. To mount antenna. Female threads for M5 To install mounting kit screws.
  • Page 36: Wibas G5 Micro-Bs / Evo-Bs

    3. Before Starting the Installation WiBAS G5 micro-BS / evo-BS Receptacles Marking Description GbE1 Gigabit Ethernet, To connect SFP module (electrical / SFP cage. optical) for carrying:  traffic  inband management. Ethernet, External GNSS module. Electrical RJ-45 (proprietary pin-out). GbE2 Gigabit Ethernet, To connect Ethernet (S-FTP) cable...
  • Page 37 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 WiBAS G5 micro-BS / evo-BS , Continued Label for PRODUCT Label WiBAS G5 micro-BS ITEM Order Code Description Product description (WiBAS G5 micro-BS). Frequency band (GHz). WiBAS G5 micro-BS determination as Low in the link pair.
  • Page 38 3. Before Starting the Installation WiBAS G5 micro-BS / evo-BS , Continued Label for PRODUCT Label WiBAS G5 evo-BS ITEM Order Code Description Product description (WiBAS G5 evo-BS). Denotes Lower and Upper band support, as follows: 24-26 = 24.25 GHz - 26.50 GHz 26-28 = 26.50 GHz - 28.50 GHz 27-29 = 27.50 GHz - 29.50 GHz ORIENTATION Label...
  • Page 39 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 WiBAS G5 micro-BS / evo-BS , Continued Other points Marking Details Anchor point. To fit lanyard for lifting to the pole. Wave guide flange. To connect antenna (HANT28180H- ΜΒ...
  • Page 40: Wibas G5 Dual-Bs

    3. Before Starting the Installation WiBAS G5 dual-BS Receptacles Marking Details To connect a Gigabit Ethernet GbE#1 Ethernet, electrical (SF/UTP) cable for traffic / inband R-J45 (100/1000 Base-T). management / superimposed DC power (POE input). GbE#2 SFP1 cage. To connect a Fiber optic cable for traffic.
  • Page 41 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 WiBAS G5 dual-BS , Continued Label Description Product description. Order code details: b1: Link determination (Low or High) b2: Duplex spacing (MHz). b3: Sub-band. Transmit and receive frequency. Continued on next page...
  • Page 42 3. Before Starting the Installation WiBAS G5 dual-BS , Continued Other points Marking Details Enclosure grounding To connect M5 grounding lug. terminal. STAT Multi-functioning LED. To provide visual indication of system status during operation. M4 screws. To install cable holder. Hooks.
  • Page 43: Radio Unit Cabling Overview

    WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 3.2. Radio Unit Cabling Overview Introduction This section describes all the available cabling connections of the following wireless equipment:  WiBAS OSDR-HUB  WiBAS G5 micro-BS  WiBAS G5 evo-BS ...
  • Page 44 3. Before Starting the Installation Radio Unit Cabling Overview , Continued External The following list shows the external equipment which is used for external equipment for powering: powering External powering using Power Injector Type WiBAS Base Station Order Code G5 micro-BS OSDR G5 dual- -HUB...
  • Page 45: Gigabit Eth Cable For Service Traffic, Inband Management And Powering

    WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Traffic, Inband Management and Powering The Gigabit Ethernet (S-FTP) cable for service traffic, inband management Ethernet cable and external powering applies to the following restriction: length restrictions The maximum length of Gigabit Ethernet (S-FTP) cable (Cat5E or Cat6),...
  • Page 46 3. Before Starting the Installation Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR-HUB injector and WiBAS G5 micro-BS / evo-BS when powering is through power injector with order code POE-AC56-IDH: Marking...
  • Page 47 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR-HUB injector, and WiBAS G5 micro-BS / evo-BS when powering is through power continued injector with order code...
  • Page 48 3. Before Starting the Installation Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR-HUB injector, and WiBAS G5 micro-BS / evo-BS when powering is through power continued injector with order code PONE-OD67-AC:...
  • Page 49 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR-HUB injector, and WiBAS G5 micro-BS / evo-BS when powering is through power continued injector with order code...
  • Page 50 3. Before Starting the Installation Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR-HUB injector, when powering is through power injector with order code POE-AC75-ID: continued Marking Cable Type...
  • Page 51 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued AC power The following schematic shows a cabling overview of WiBAS G5 dual-BS injector, when powering is through power injector with order code POE-AC112-ID: continued Marking...
  • Page 52 3. Before Starting the Installation Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued AC power The following schematic shows a cabling overview of WiBAS G5 dual-BS injector, when powering is through power injector with order code POE-HP-OD-AC: continued Marking...
  • Page 53 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued DC power The following schematic shows a cabling overview of WiBAS OSDR-HUB injector and WiBAS G5 micro-BS / evo-BS when powering is through power injector with order code PONE-OD-DC:...
  • Page 54 3. Before Starting the Installation Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued DC power The following schematic shows a cabling overview of WiBAS G5 dual-BS injector, when powering is through power injector with order code POE-HP-OD67-DC: continued Marking...
  • Page 55 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued IDU with POE The following schematic shows a cabling overview of WiBAS OSDR-HUB capability and WiBAS G5 micro-BS / evo-BS when powering is through IDU with POE capability and order code IDU-O4P:...
  • Page 56 3. Before Starting the Installation Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued IDU with POE The following schematic shows a cabling overview of WiBAS OSDR-HUB capability, and WiBAS G5 micro-BS / evo-BS when powering is through IDU with continued POE capability and order code IDU-O10P:...
  • Page 57 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Traffic, Inband Management and Powering , Continued IDU with POE The following schematic shows a cabling overview of WiBAS OSDR-HUB capability, and WiBAS G5 micro-BS / evo-BS when powering is through IDU with continued POE capability and modem order code...
  • Page 58: Gigabit Eth Cable For Service Powering / Fiber Optic Cable For Service Traffic, Inband Management

    3. Before Starting the Installation Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management Ethernet cable The Gigabit Ethernet (S-FTP) cable for service external powering through length AC power injector applies to the following restriction: restrictions The maximum length of Gigabit Ethernet (S-FTP) cable (Cat5E or Cat6), between WiBAS...
  • Page 59 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued The Gigabit Ethernet (S-FTP) cable for service external powering through Ethernet cable DC power injector applies to the following restriction: length...
  • Page 60 3. Before Starting the Installation Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued The following tables shows the maximum length of optical fiber cables in Fiber optic combination with the SFP type: cable length restrictions Optical Fiber Cable Lengths combined with Gigabit Ethernet SFP:...
  • Page 61 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR- injector HUB and WiBAS...
  • Page 62 3. Before Starting the Installation Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR- injector, HUB and WiBAS G5 micro-BS / evo-BS when powering is through continued power injector with order code POE-AC60-ID:...
  • Page 63 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR- injector, HUB and WiBAS...
  • Page 64 3. Before Starting the Installation Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR- injector, HUB and WiBAS G5 micro-BS / evo-BS when powering is through continued power injector with order code POE-ID-AC72:...
  • Page 65 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued AC power The following schematic shows a cabling overview of WiBAS OSDR- injector, HUB when powering is through power injector with order code...
  • Page 66 3. Before Starting the Installation Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued DC power The following schematic shows a cabling overview of WiBAS OSDR- injector HUB and WiBAS G5 micro-BS / evo-BS when powering is through power injector with order code PONE-OD-DC: Marking...
  • Page 67 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued DC power The following schematic shows a cabling overview of WiBAS OSDR- injector, HUB and WiBAS...
  • Page 68 3. Before Starting the Installation Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued DC power The following schematic shows a cabling overview of WiBAS OSDR- injector, HUB and WiBAS G5 micro-BS / evo-BS when powering is through continued power injector with order code IDU-O4P:...
  • Page 69 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued DC power The following schematic shows a cabling overview of WiBAS OSDR- injector, HUB and WiBAS...
  • Page 70 3. Before Starting the Installation Gigabit ETH cable for service Powering / Fiber Optic cable for service Traffic, Inband Management , Continued DC power The following schematic shows a cabling overview of WiBAS OSDR- injector, HUB and WiBAS G5 micro-BS / evo-BS when powering is through continued power injector with order code OmniBAS...
  • Page 71: Direct Powering / Fiber Optic Cable For Service Traffic, Inband Management

    WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Direct Powering / Fiber Optic cable for service Traffic, Inband Management Introduction This paragraph describes the cabling overview of WiBAS G5 dual-BS when direct powering is used for power and fiber optic cable is used for service traffic and inband management.
  • Page 72 3. Before Starting the Installation Direct Powering / Fiber Optic cable for service Traffic, Inband Management , Continued Direct powering Marking Description WiBAS G5 dual-BS with sectoral 90 integrated antenna. GbE1 interface for Gigabit Ethernet cable (SF/UTP Cat5E) GbE2 interface for fiber optic cable (with SFP module). GbE3 interface for fiber optic cable (with SFP module).
  • Page 73: Site Prerequisites

    WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 3.3. Site Prerequisites Site survey Site survey should be done before start the installation taking in consideration the following: Premises information  Site details (address, contact persons, GPS and/or map co-ordinates, etc.).
  • Page 74 3. Before Starting the Installation Site Prerequisites , Continued  Suitable electrical network port distributor should be available. Network port distributors  The exact location of the network port distributor, as well as the network ports to reserve, should be known prior to installing the equipment. ...
  • Page 75 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Site Prerequisites , Continued Circuit The following table provides the circuit breakers characteristics for breakers powering of power injectors: Order Code Required Circuit Breaker   single-pole MCB 6 A POE-AC75-ID ...
  • Page 76 3. Before Starting the Installation Site Prerequisites , Continued Appendix C – Antenna Pole Space Pole space For pole space requirements refer to requirements Requirements. Pole diameters For pole diameters refer to the paragraphs below: Order Code Pole Diameter MTK-DMA-BX OSDR-360-ANT-MNT-KIT 48 mm to 100 mm HANT2628360V...
  • Page 77 WiBAS / WiBAS G5 Base Stations Installation & Cabling Manual - Edition 3.2 Site Prerequisites , Continued Tower or If the construction is sensitive to sway angles and twisting then try to Monopole install the antenna in a lower height platform (if it is available and installation LOS is clear) in order to minimize the problem.

Table of Contents