In swimming pools, fish ponds, etc, ensure location is clear of people and animals, including removal of fish from pond.
9
This pump is not designed for continuous use in a fish pond or similar water feature or display.
8
DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.
8
DO NOT use the pump for any purpose other than for that which it is designed.
8
DO NOT use to pump chemicals, fuels or salt water.
8
DO NOT insert hands into the mouth of the pump as this could lead to injury.
8
DO NOT use to pump septic tanks or settling pits. DO NOT pump any liquids other than water.
8
DO NOT operate the pump out of water. The pump pick up area must be completely submerged during operation.
8
DO NOT exceed the maximum submersible depth - see specifications.
8
DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.
8
DO NOT use in swimming pools if people could come into contact with the water whilst pump is in use.
8
DO NOT use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids.
8
DO NOT carry the pump by its electrical cable, or outlet pipe. Use the handle only.
8
When not in use switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe
8
location.
WARNING! DO NOT allow uncontrolled discharge of contaminated water which would pollute the environment.
Children from age 8 years and above, persons with reduced physical, sensory or mental capabilities, those with lack of experience
and knowledge can use the appliance, if they have been given supervision or instruction concerning use of the appliance In a safe
way to understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance on the
appliance shall not be maintained by children without supervision.
2. INTRODUCTION
WPC100.V3: Manufactured from corrosion resistant materials with steel motor case and polypropylene base cover. Max. Output: 100L(22gal)/
min, Max. Head: 6m. Minimum water depth of just 5mm. Designed for clean water although this pump will accept small particles up to 5mm.
Suitable for the effective drainage of cellars, sinks, cisterns, baths and the general transfer of water.
WPC235A.V3: Manufactured from corrosion resistant materials with steel motor case and polypropylene base cover. Minimum water depth of
just 5mm. Designed for clean water although this pump will accept small particles up to 5mm. Automatic low water cut-out. Suitable for the
effective drainage of cellars, sinks, cisterns, baths and the general transfer of water.
WPC250A.V2: Manufactured from corrosion resistant materials with steel motor case and polypropylene base cover. Minimum water depth of
just 5mm. Designed for clean water although this pump will accept small particles up to 5mm. Automatic low water cut-out. Suitable for the
effective drainage of cellars, sinks, cisterns, baths and the general transfer of water.
3. SPECIFICATION
Model No.
WPC100.V3
Cut out
Manual
Maximum head
6m
Maximum output/min
100L/min
Maximum particle size
5mm
Maximum water depth
7m
Minimum water depth
5mm
Motor power
250W
Outlet OD
25/38mm
Supply
230V
4. BEFORE USE
4.1.
Read all safety warnings and all instructions. Failure to follow all warnings and instructions may result in electric shock, fire and/or
serious injury. Save all warnings and instructions for future reference.
4.2.
The pump can be connected to any shock-proof plug which has been installed according to regulations in force.
WARNING! When the pump is to be used near swimming pools or garden ponds and in their area of protection, it must be
equipped with a PRCD (residual current circuit breaker) with a nominal trip current of max.30mA . The pump must not be
operated while people are in the swimming pool or in the garden pond. Please contact your electrician.
WARNING! (Important for your own security) Before starting to run your new submersible pump, please have the following items
checked by an electrician:
• Ground connection
• Zero conductor
• Fault current breaker switch must correspond the safety regulations in force in that region.
They must work faultlessly.
4.3.
The electrical connections must be protected from moisture.
4.4.
If there is danger of flooding, the electrical connections must be taken to higher ground.
4.5.
Circulation of aggressive fluids, as well as the circulation of abrasive materials must be avoided at all costs.
4.6.
The submersible motor-driven pump must be protected from frost.
4.7.
The pump must be protected from running dry.
4.8.
Access on the part of children should also be prevented with appropriate measures.
4.9.
These submersible pumps is designed for the circulation of water with a maximum temperature of 35° C. This pump may not be
used for other fluids, especially motor fuels, cleaning fluids, and other chemical products.
© Jack Sealey Limited
WPC235A.V3
WPC250A.V2
Automatic
Automatic
8.5m
9.5m
217L/min
250L/min
5mm
5mm
7m
7m
5mm
5mm
750W
900W
25mm/38mm
25mm/38mm
230V
230V