Vanair Goodall CAP-START Operation Manual And Parts List

Vanair Goodall CAP-START Operation Manual And Parts List

Hydraulic-driven 12v/24v battery starter-charger
Table of Contents

Advertisement

HYDRAULIC-DRIVEN • 12V/24V BATTERY
OPERATION MANUAL AND PARTS LIST
NOTE
This publication contains the
latest information available at
the time of preparation. Every
eff ort has been made to ensure
accuracy.
Vanair Manufacturing, Inc.
reserves the right to make
design change modifi cations
or improvements without prior
notifi cation.
NOTE
Use only Vanair Van-
guard™Premium Synthetic
Compressor Oil and Genuine
Vanair Parts. Inspect and
replace damaged components
before operation. Substituting
non-Vanair oil or non-genuine
Vanair fi lter components WILL
VOID THE COMPRESSOR
WARRANTY!
KEEP THE MANUAL
WITH THE VEHICLE
STARTER • CHARGER
Vanair Manufacturing, Inc.
10896 West 300 North
Michigan City, IN 46360
Telephone (toll free): (800) 526-8817
Service (toll free): (844) VAN-SERV
(844) 826-7378
Telephone: (219) 879-5100
Service Fax: (219) 879-5335
Parts Fax: (219) 879-5340
Sales Fax: (219) 879-5800
www.vanair.com
©2022 Vanair Manufacturing, Inc.
All rights reserved
Read this manual before install-
ing, operating or servicing this
equipment. Failure to comply
with the operation and mainte-
nance instructions in this man-
ual will VOID THE EQUIPMENT
WARRANTY.
NOTE
Making unauthorized modifi ca-
tions to the system components
WILL VOID THE WARRANTY!
Always inform Vanair Manufac-
turing, Inc., before beginning
any changes to the Cap•Start
Hydraulic-Driven Package.
P/N: 090189-OP_r0
Eff ective Date:
JUNE 2022

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the Goodall CAP-START and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vanair Goodall CAP-START

  • Page 1 Inc., before beginning before operation. Substituting any changes to the Cap•Start non-Vanair oil or non-genuine Michigan City, IN 46360 Hydraulic-Driven Package. Vanair fi lter components WILL Telephone (toll free): (800) 526-8817 VOID THE COMPRESSOR WARRANTY! Service (toll free): (844) VAN-SERV (844) 826-7378...
  • Page 2 PRE-AUTHORIZED PRIOR from Vanair or (Vanair designated facility) within the fi rst year of Vanair must be notifi ed in writing within thirty (30) days of any the applicable warranty period. Any additional expedited freight TO PERFORMING such defect or failure.
  • Page 3: Table Of Contents

    SECTION 3: INSTALLATION ............3 - 1 MACHINE PACKAGE RECEIPT/INSPECTION ............3 - 1 GENERAL INSTRUCTIONS ..................3 - 1 DETERMINING THE MACHINE MOUNTING LOCATION ........... 3 - 2 Continued on next page... 090189-OP_r0 (JUNE-2022) TOC - I VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 4 ROUTINE START-UP PROCEDURE .............. 4 - 1 ROUTINE SHUTDOWN PROCEDURE (FIRST AND ROUTINE) ........ 4 - 2 EXTREME CONDITION OPERATION ................. 4 - 3 Continued on next page... TOC - II 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 5 CANOPY AND PARTS ....................7 - 18 DECAL IDENTIFICATION/LOCATION - 1 OF 2 ............7 - 20 DECAL IDENTIFICATION/LOCATION - 2 OF 2 ............7 - 21 Continued on next page... 090189-OP_r0 (JUNE-2022) TOC - III VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 6 7.10 WIRING DIAGRAM - 1 OF 2 ..................7 - 22 7.11 HOSE INSTALLATION GUIDE ................... 7 - 23 TABLE 7B: MAINTENANCE TRACKING LOG ..............7 - 24 TOC - IV 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 7: Warranty

    VANAIR PARTS individual serial numbers respectively (see Figure W-1). Have a list of the symptoms/ This process must be used by owners of Vanair ® condition/malfunctions along with any ap- equipment in situations where a warranted item plicable temperature and pressure read-...
  • Page 8 Before sending a warranty part to a customer, Vanair will need a P.O. or credit card number to cover the cost of the part and shipping. After the part is analyzed and deemed to be covered under warranty, Vanair will issue credit to the customer.
  • Page 9: Safety

    1.3.2 WARNINGS The products provided by Vanair Manufacturing, ® Inc., are designed and manufactured for safe op- • DO NOT perform any modifi cations to this eration and maintenance. But it is ultimately the equipment without prior factory approval.
  • Page 10: Cautions

    Severe personal • DO NOT install safety devices and/or replace- injury and equipment damage can result if op- ment parts other than authorized Vanair ® erated at speeds above the maximum. placement parts.
  • Page 11: California Proposition 65 Warnings

    Always dispose of machine fl uids under the guid- damaged or illegible. ance of all applicable local, regional and/or fed- eral law. CALIFORNIA PROPOSITION Vanair encourages recycling when allowed. For 65 WARNINGS additional information, consult the container label of the fl uid in question. WARNING Discharge from this machine may cause cancer and/or reproductive harm.
  • Page 12 Cap•Start Hydraulic-Driven SECTION 1: SAFETY 12V/24V • Battery Starter • Charger BLANK PAGE 1 - 4 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 13: Section 2: Specifications

    1/4 - 20 UNC 6 ft-bs 5/16 - 18 UNC 13 ft-lbs 3/8 - 16 UNC 23 ft-lbs 1/2 - 13 UNC 55 ft-lbs 3/4 - 10 UNC 200 ft-lbs 090189-OP_r0 (JUNE-2022) 2 - 1 VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 14 OUTPUT CABLE CONNECTOR POWER CONNECTION AC GEN FAN CASE DRAIN AC GENERATOR HYDRAULIC RETURN SOLENOID HYDRAULIC SUPPLY PRESSURE RELIEF VALVE POWER CONNECTOR Figure 2-1: Machine Main Component Locations 2 - 2 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 15: Section 3: Installation

    DISCLAIMER NOTE DO NOT install in any enclosed space without In order to prevent accidental damage to vehi- fi rst contacting Vanair. cle components (fuel tanks, lines, brake lines, wiring harnesses), note their location before drilling any holes. VANAIR MANUFACTURING, INC.
  • Page 16: Determining The Machine Mounting Location

    Refer to Figure 3-3 to determine the additional integration (including oil reservoir size, hy- minimum space requirement measurements. draulic pressure relief, hose size, etc.) for your application. • The external gauges/display must be easily vis- 3 - 2 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 17 Cap•Start Hydraulic-Driven SECTION 3: INSTALLATION 12V/24V • Battery Starter • Charger Figure 3-2: Identifi cation and Dimension Diagram 050211ID_r0 VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 3 - 3 (844) VAN-SERV • www.vanair.com...
  • Page 18: Hydraulic System Filtration

    PREFERRED SHAPE: TALL AND NARROW FILTRATION SHAPE TO AVOID: BROAD AND SHALLOW Vanair recommends using a 10 micron oil fi lter on Figure 3-3: Reservoir Design Shape the hydraulic oil return line. Flow rating of the fi lter 3 - 4 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC.
  • Page 19: Mandatory Reservoir Features

    • An in-line fi lter on the return line is needed to non-tracked or infrequent maintenance practic- protect the system against contaminants be- es may cause this strainer to potentially promote VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 3 - 5 (844) VAN-SERV • www.vanair.com...
  • Page 20: Recommended Hydraulic System Specifications

    (2) ga wire (reference Vanair ground • Load sense = #4 JIC = 1/4” hose (Used for strap no. 267498).
  • Page 21: Routing

    . • The duty cycle and ambient operating tempera- tures. • Other hydraulic equipment which may share the same hydraulic supply system (Vanair recommends a dedicated pump and hydraulic circuit). CONNECTING THE HYDRAU- LIC SUPPLY AND RETURN...
  • Page 22 Cap•Start Hydraulic-Driven SECTION 3: INSTALLATION 12V/24V • Battery Starter • Charger BLANK PAGE 3 - 8 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 23: Section 4: Operation

    5. Allow air pressure to build up in the re- ceiver tank. NOTE 6. Move the PTO ON/ OFF switch to the Flow control needs to be set by the installer for OFF position. closed center units. VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 4 - 1 (844) VAN-SERV • www.vanair.com...
  • Page 24: Routine Shutdown Procedure (First And Routine)

    Figure 4-1: Instrument Panel ROUTINE SHUTDOWN PRO- CEDURE (FIRST AND ROU- TINE) IMPORTANT If start-up and shut-down procedures are not followed, damage to the system and its compo- nents may occur. 4 - 2 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 25 CIRCUITS SUCH AS HEADLIGHTS OR BLOWER MO TOR. IF THIS ERROR TIME REMAINING: XX.XX PERSISTS REFER TO OWNER’S MANUA L Start Vehicle Start Vehicle Figure 4-2: Controller Screen Identifi cation and Navigation VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 4 - 3 (844) VAN-SERV • www.vanair.com...
  • Page 26: Section 4: Operation (Continued)

    Cap•Start Hydraulic-Driven SECTION 4: OPERATION 12V/24V • Battery Starter • Charger BLANK PAGE 4 - 4 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 27: Section 5: Maintenance

    Parts Fax: (219) 879-5340 Sales Fax: (219) 879-5800 www.vanair.com NOTE Operating the machine package in a severe environment may require more frequent service intervals. VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 5 - 1 (844) VAN-SERV • www.vanair.com...
  • Page 28: Parts Replacement And Adjustment Procedures

    For belt replacement order belt no. 282389 (quantity of three [3]). Tension give is approximately 1/4" (5-5.5 lbs new; 4.5-5.0 lbs broken in) of tension play. Figure 5-1: Drive Belt Adjustment 5 - 2 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 29: Replacing The Belt

    fi rst, then positon the belt on both sheave tracks as shown in Figure 5-1. 3. Once belts are properly positioned, the belt is ready to be tightened. 090189-OP_r0 (JUNE-2022) 5 - 3 VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 30 Cap•Start Hydraulic-Driven SECTION 5: MAINTENANCE 12V/24V • Battery Starter • Charger BLANK PAGE 5 - 4 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 31: Section 6: Troubleshooting

    12V/24V • Battery Starter • Charger SECTION 6: TROUBLESHOOTING GENERAL INFORMATION Although Vanair strives to anticipate situations that may occur during the operation life of the ma- This section contains symptoms and usual caus- chine package, the Troubleshooting Guide may es for the most common types of problems that not cover all possible situations.
  • Page 32: Troubleshooting Guide - Hydraulics

    Pump is damaged Check for damaged pump or pump drive—replace as neces- sary, and align coupling. Pump is assembled improperly Overhaul or replace pump. Table continued on next page 6 - 2 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 33 Fluid may be too cold; allow system to warm up. Fluid may be fouled; change system fl uid to correct viscosity fl uid. Table continued on next page 090189-OP_r0 (JUNE-2022) 6 - 3 VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 34 Cylinder or motor is worn or damaged Overhaul or replace cylinder or motor. Hydraulic Motor Rotates Flow is excessive Refer to information under INCORRECT FLOW CONDITION in Excessively this guide. 6 - 4 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 35: Section 7: Illustrated Parts List

    (844) 826-7378 NOTE Telephone: (219) 879-5100 Service Fax: (219) 879-5335 When contacting the Vanair Service Department, please have machine serial number on hand to quickly expe- Parts Fax: (219) 879-5340 dite service. Serial number can be located on the serial plate, as shown.
  • Page 36 Should any part of the machine package that is not listed in Table 7A become damaged or inoperable, non-use, consult Section 5.4.2, Long Term Storage. contact the Vanair Service Department. 7 - 2 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 37 Cap•Start Hydraulic-Driven SECTION 7: ILLUSTRATED PARTS LIST 12V/24V • Battery Starter • Charger NOTES VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 3 (844) VAN-SERV • www.vanair.com...
  • Page 38: Finished Assembly - 1 Of 3

    3. ALL BOLTS TO BE TORQUED TO THEIR RESPECTIVE SAE TORQUE SPECIFICATIONS, FOR THEIR GRADES AND SIZES, UNLESS OTHERWISE SPECIFIED. (2X) SEE NOTE #2 NOTE #1 SEE NOTE #2 6130217ID_r0_1of3 7 - 4 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 39 828304-175 DECAL GROUP CAPSTART 3000, 6110154ID HYDRAULIC CAPSCREW, HEX GR5 1/4-20 x 1/2 829104-050 ID, MANIFOLD ASSY, CS3KH 6120460ID PLEASE NOTE: WHEN ORDERING PARTS, INDICATE MACHINE SERIAL NUMBER. VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 5 (844) VAN-SERV • www.vanair.com...
  • Page 40: Finished Assembly - 2 Of 3

    HERE NOTES: 1. HARDWARE SUPPLIED WITH RELAYS 2. ALL BOLTS TO BE TORQUED TO THEIR RESPECTIVE SAE TORQUE SPECIFICATIONS, FOR THEIR GRADES AND SIZES, UNLESS OTHERWISE SPECIFIED. 6130217ID_r0_2of3 7 - 6 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 41 828304-175 DECAL GROUP CAPSTART 3000, 6110154ID HYDRAULIC CAPSCREW, HEX GR5 1/4-20 x 1/2 829104-050 ID, MANIFOLD ASSY, CS3KH 6120460ID PLEASE NOTE: WHEN ORDERING PARTS, INDICATE MACHINE SERIAL NUMBER. VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 7 (844) VAN-SERV • www.vanair.com...
  • Page 42: Finished Assembly - 3 Of 3

    7.2 FINISHED ASSEMBLY - 3 OF 3 282577-005 HARNESS CLAMP (+) 282039 ALTERNATOR MANIFOLD CLAMP (-) 282418 SOL VALVE CONN 300A SENSOR HARNESS 282040 SENSOR 282577-006 CONTROLLER 277892-02 DISPLAY 6130217ID_r1_3of3 7 - 8 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 43 NEGATIVE 282577-003 CUSTOMER CONN. D +12VDC OUTPUT SIGNAL FOR REMOTE INDICATOR OF HYDRAULIC MOTOR BEING ON RELAY 1 HARNESS 282039 282577-004 282577-006 TO ALTERNATOR NEG. (-) 6060337ID_r1_1of2 (TP) VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 9 (844) VAN-SERV • www.vanair.com...
  • Page 44 2. ALL BOLTS TO BE TORQUED TO THEIR RESPECTIVE SAE TORQUE SPECIFICATIONS, FOR THEIR GRADES AND SIZES, UNLESS OTHERWISE SPECIFIED. 3. HARDWARE TO BE SUPPLIED WITH THE CAPACITORS. 6060337ID_r1_2of2 7 - 10 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 45 CAPSCREW, HEX GR5 5/16-18 x 0.75 829105-075 SCREW,MACHINE 10-32 X 1.0 831702-100 WASHER, FLAT 5/16 838205-071 WASHER, LOCK 1/4 838504-062 WASHER, LOCK 5/16 838505-078 PLEASE NOTE: WHEN ORDERING PARTS, INDICATE MACHINE SERIAL NUMBER. VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 11 (844) VAN-SERV • www.vanair.com...
  • Page 46: Alternator Assembly

    RESPECTIVE SAE TORQUE SPECIFICATIONS, FOR THEIR GRADES AND SIZES, UNLESS OTHERWISE SPECIFIED. REAR REFERENCE 3. USE MEDIUM STRENGTH BLUE THREAD LOCKER. SEE NOTE #1 (4X) (4X) SEE NOTE #3 6050122ID_r0 7 - 12 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 47 CAPSCREW, HEX HD GR 8 1-8 UNC-2A x 4.00 LG 829406-400 SCREW, SER WASH #10-24 x 0.5 829702-050 WASHER, FLAT 3/8” 838206-071 PLEASE NOTE: WHEN ORDERING PARTS, INDICATE MACHINE SERIAL NUMBER. VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 13 (844) VAN-SERV • www.vanair.com...
  • Page 48: Motor Assembly

    2. ALL BOLTS TO BE TORQUED TO THEIR RESPECTIVE SAE TORQUE SPECIFICATIONS, FOR THEIR GRADES AND SIZES, UNLESS OTHERWISE SPECIFIED. 3. LUBRICATE ALL ELASTOMERIC SEALS/GASKETS/O-RINGS BEFORE TIGHTENING. DO NOT TIGHTEN BOLT OR NUT NOTE #1 (3X) 6100281ID_r1 7 - 14 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 49 NUT, HEX 3/8-16 825206-337 CAPSCREW, HEX GR5 3/8-16 x 1.25 829106-125 WASHER, FLAT 5/16” x 0.875” 838206-071 WASHER, LOCK 3/8 838506-094 PLEASE NOTE: WHEN ORDERING PARTS, INDICATE MACHINE SERIAL NUMBER. VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 15 (844) VAN-SERV • www.vanair.com...
  • Page 50: Manifold Assembly

    CONNECTOR, O-RING 3/4 x 3/4 JIC 260387-112 CONNECTOR, #12 MSAE x #8 MJIC 260387-132 MANIFOLD, HYDRAULIC 0-25GPM 281334 3000PSI PLEASE NOTE: WHEN ORDERING PARTS, INDICATE MACHINE SERIAL NUMBER. 6120460ID_r0 7 - 16 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 51: Control Module Assembly

    PLEASE NOTE: WHEN ORDERING PARTS, INDICATE MACHINE SERIAL NUMBER. NOTES: 1. ALL BOLTS TO BE TORQUED TO THEIR RESPECTIVE SAE TORQUE SPECIFICATION, FOR THEIR GRADES AND SIZES, UNLESS OTHERWISE SPECIFIED. 6060352ID_r0 VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 17 (844) VAN-SERV • www.vanair.com...
  • Page 52: Canopy And Parts

    Cap•Start Hydraulic-Driven SECTION 7: ILLUSTRATED PARTS LIST 12V/24V • Battery Starter • Charger 7.8 CANOPY AND PARTS 6030207ID_r0 7 - 18 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 53 PANEL, BACK CS3KH 281313 PANEL, LEFT CS3KH 281315 PANEL, RIGHT CS3KH 281316 LID, CAPSTART3000 HYDRAULIC 281317 PANEL, FRONT CS3KH 6030207ID-A PLEASE NOTE: WHEN ORDERING PARTS, INDICATE MACHINE SERIAL NUMBER. VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 19 (844) VAN-SERV • www.vanair.com...
  • Page 54: Decal Identification/Location - 1 Of 2

    PLEASE NOTE: WHEN ORDERING PARTS, INDICATE MACHINE SERIAL NUMBER. WARNING DO NOT REMOVE OR COVER ANY SAFE- TY DECAL. Replace any safety decal that becomes damaged or illegible. 6110154ID_r1_1of2 7 - 20 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 55: Decal Identification/Location - 2 Of 2

    DESCRIPTION PART NUMBER ITEM DESCRIPTION PART NUMBER LOGO, CAPSTART BY STARTALL 300 0 AMPS 12/24V 282481 DECAL, VANAIR SERIAL TAG 281373-002 LOGO, GOODALL WE START ENGINES 277884 DECAL, CASE DRAIN 5/8 X 1-3/4 276941 DECAL, WARN ELCTRICL SHOCK 2.0” TRIANGLE...
  • Page 56 B-10 OUT 04 IN 16 B-13 OUT 03 HARNESS: 277892-02 IN 04 M12 5-PIN A-CODED OUT 02 IN 03 CUSTOMER OUT 01 CONNECTOR IN 06 HMI 277096 281318_r0 7 - 22 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...
  • Page 57 Allow ample free length for fl exing. 3. Exceeding minimum bend 6. When properly routing, radius will greatly reduce hose use clamps to secure the assembly life. hose in its proper position. VANAIR MANUFACTURING, INC. 090189-OP_r0 (JUNE-2022) 7 - 23 (844) VAN-SERV • www.vanair.com...
  • Page 58 Cap•Start Hydraulic-Driven SECTION 7: ILLUSTRATED PARTS LIST 12V/24V • Battery Starter • Charger TABLE 7B: MAINTENANCE TRACKING LOG DATE DESCRIPTION OF MAINTENANCE PART(S) REPLACED 7 - 24 090189-OP_r0 (JUNE-2022) VANAIR MANUFACTURING, INC. (844) VAN-SERV • www.vanair.com...

Table of Contents

Save PDF