Quick Start — Physical Installation
This section describes how to physically install a WSS. For more information about physical installation, see Nortel
WLAN—Security Switch 2300 Series Installation and Basic Configuration Guide.

Installing the Nortel WLAN Security Switch

Estimated timing: 10 minutes
A WSS can be installed on either a tabletop surface or in an equipment rack.
methods are available for each WSS model.
Table 2: Installation methods
WSS model
2350
2360/2361
2380
2382
When choosing a location for the WSS, ensure that:
The power outlet is within 1.82 m (6 ft) of the device.
There is proper heat dissipation from and adequate ventilation around the
switch.
Tabletop Installation
Step
1
2
3
4
5
Equipment Rack Installation
Step
1
2
Tabletop
X
X
X
X
Action
Ensure that the table surface supports at least 3 kg (6.6 lb).
Carefully turn the WSS upside down on a clean work surface with no debris.
Wipe the four placement locations for the rubber feet to clear away any oil or dust.
Each location area is marked with an 'X'.
Attach the four rubber adhesive feet over the 'X's.
Turn the WSS right-side up, and place the switch in position on the table.
Action
Remove the four bracket screws from each side of the WSS.
Align a bracket over the screw holes:
For a front-mount equipment rack, align the bracket so that the bracket flange is
flush with the WSS front panel and away from the switch.
For a center-mount equipment rack, align the bracket so that the bracket flange
is located near the center screw holes, as shown in
Nortel WLAN - Security Switch 2300 Series Quick Start Guide
Table 2
outlines which installation
Front-mount rack
Center-mount rack
X
X
X
X
X
End
Figure
15