Installationsanleitung / Installation Instruction FLD2...
FLD2...
2
3
1
click
Installation / Wiring diagram
FLD2
F
=I
max.
L
Leitungsführung / Cable routing
3 PE4
1 PE2
3
2
0,14 - - 2,5 mm
5-6 mm
5-6 mm
in
out
F
1
2
PE
3 PE4
PE4
Coupling
1 PE2
2
Maßbild / Dimensions
3
4
zu schützen-
des Endgerät
PE (1)
Protected
Device
Potentialausgleich PE (1) herstellen!
Install equipotential bonding PE (1)
Schaltbild / Wiring diagram
Typ
FLD
FLD
2- - 5
2- - 12
Maximum continuous operating voltage Uc
8 V
13 V
DC
Maximum continuous operating voltage Uc
5 V
9 V
AC
Dividing unit
Protection rating
Rated current I
L
Capacitance C line-line
Capacitance C line-earth
Isolation resistance R
> 1MS
iso
Series resistance R
s
Protection level U
line-line
30 V
60 V
p
Protection level U
line-earth
15 V
30 V
p
Impulse durability line-line
C1: 1 kV / 0,5 kA
C1: 1 kV / 0,5 kA
Impulse durability line-earth
Total discharge current I
Total (8/20)
C2: 2 kV / 1 kA
Total discharge current I
Total
Temperature range 2
Connection cross-section, rigid
Connection cross-section, multi-wire
Connection cross-section, flexible
UL-values
Model
Rated
Voltage Breakdown Range,
Number
current
L ---L
FLD2 ---5
580 mA
16.5 ---27.5
FLD2 ---12
580 mA
36 ---60
FLD2 ---24
580 mA
70.5 ---117.5
FLD2 ---48
580 mA
150 ---250
FLD2 ---110
580 mA
330 ---550
UL 497B
UL
IEC 61643--21:2009
IEC
Das Überspannungsschutzgerät darf nur im
Safety
spannungsfreien Zustand eingebaut werden!
instructions
The SPD may only be installed into the circuit
on voltage free lines!
Head Office
OBO BETTERMANN GmbH & Co. KG
Postfach 1120 · 58694 Menden, Germany
Hüingser Ring 52 · D-58710 Menden
Tel. +49 (0)2373-89-0·Fax +49 (0)2373-89-238
E-Mail: info@obo.de · www.obo-bettermann.com
FLD
FLD
FLD
2- - 24
2- - 48
2- - 110
28 V
53 V
122 V
19 V
37 V
86 V
1
IP 20
1 A
< 10 nF
< 1 nF
< 10 nF
> 10MS
> 100MS
120 :H±20%
120 V
240 V
500 V
60 V
130 V
300 V
C1: 0,5
C2: 5 kV
kV / 0,25
/ 2,5 kA
kA
C1: 0,5
C2: 5 kV
kV / 0,25
/ 2,5 kA
kA
-
C1: 1 kV
C2: 10
/ 0,5 kA
kV / 5 kA
-40°C - + 80°C
2
0,14- -2,5 mm
2
0,14- -2,5 mm
2
0,14- -2,5 mm
Vdc 100 V/s
L ---G
184 ---276
184 ---276
184 ---276
184 ---276
184 ---276
Technical Hotline
Telefon +49 (0)2373/89-1500
Telefax
+49 (0)2373/89-7777
E-Mail
hotline@obo.de

Advertisement

loading

Summary of Contents for OBO Bettermann FLD2 Series

  • Page 1 Zustand eingebaut werden! Coupling instructions The SPD may only be installed into the circuit on voltage free lines! Head Office OBO BETTERMANN GmbH & Co. KG Technical Hotline Postfach 1120 · 58694 Menden, Germany Telefon +49 (0)2373/89-1500 1 PE2 1 PE2 Hüingser Ring 52 ·...
  • Page 2 Sicherheitshinweise Safety instructions Indications de sécurité Norme di sicurezza The device is a surge arrester (surge Das Gerät ist ein Überspannungsa- L’appareil est un appareil de parasur- Il appareccio è un limitatore di sovra- El protector contra sobretensione se protection device, SPD) to IEC bleiter (SPD-Surge-Protection-Devi- tension (SPD-Surge-Protection-De- tensione (SPD = Surge- Protective-...

This manual is also suitable for:

Fld2-5Fld2-12Fld2-24Fld2-48Fld2-110