WELCOME Congratulations on choosing to buy a Sheffield product. All products brought to you by Sheffield are manufactured to the highest standards of performance and safety, and, as part of our philosophy of customer service and satisfaction, are backed by our comprehensive 24 Month warranty.
1 x Warranty Card Confirm all parts before disposing of the carton. Safely dispose of all plastic bags and other packaging components. They may be potentially dangerous to children. TECHNICAL SPECIFICATION MODEL PL617 POWER SUPPLY 220-240V~ / 50Hz CLASS I, IPX1 COOLING CAPACITY 7000BTU/h (2.05kW)
IMPORTANT SAFETY INSTRUCTIONS READ CAREFULLY AND KEEP FOR FUTURE REFERENCE Carefully read this manual before using this appliance. Ensure that you know how the appliance functions and how to operate it. Maintain the appliance in accordance with the instructions to ensure that it functions properly.
Page 6
Any person who is involved with working on or breaking into a refrigerant circuit should hold a currently valid certificate from an industry-accredited assessment authority, which authorises their competence to handle WARNING refrigerants safely in accordance with industry, recognized assessment specification. This unit uses a flammable refrigerant.
Page 7
Never place the appliance close to a radiant heat source. Avoid contact with the moving parts. Keep hands, hair, clothing, away from the blade of the fan during operation to reduce the risk of injury to person and/or damage to the unit. ...
Page 8
Water Do not immerse the appliance or its supply cord in water. Do not use with wet hands or use in damp or humid situations. Never use this appliance in the immediate surrounds of a bath, a shower, or a swimming pool or other liquids.
Page 9
THE FOLLOWING SHOULD ALWAYS BE OBSERVED FOR SAFETY The environmentally friendly R290 is used as the refrigerant. R290 has no damaging influence on the ozone layer (ODP), a negligible greenhouse effect (GWP) and is available worldwide. Because of its efficient energy properties, R290 is highly suitable as a coolant for this application.
ASSEMBLY AND PARTS 1. Control Panel 5. Castor 2. Air Outlet 6. Drain Opening 3. Handle 7. Air Exhaust 4. Air Inlet with Filter Exhaust Hose Hose Connector Window Kit Adapter Remote Control Sliding Window Kit AFTER SALES SUPPORT Email: service@prolinkbrands.co.nz Page Phone: 0508 776 546 - Mon-Fri 8:30am –...
Page 11
CONTROL PANEL 1. POWER Press to switch the machine on or off. Press to switch the operation mode between 2. MODE cool, dehumidify, and fan. Press to adjust the fan speed between HIGH 3. SPEED and LOW. Indicator for showing what fan speed is 4.
INSTALLATION Note: If the exhaust is not vented either out of the window or into the Roof space this unit will not effectively cool down the room. If tipped more than 45°, allow the unit to sit upright for at least 24 hours before start-up.
Page 13
2. Connect the windows kit adapter to the other end of the exhaust hose. 3. Extend the adjustable sliding window kit to the length of your window. Connect the exhaust hose to the window kit. 4. Close your window to secure the kit in place. It needs to hold the window kit firmly in place, secure the window kit with duct tape if required.
OPERATION Before First Use After unpacking, ensure that the contents are complete and check for any transit damage in order to avoid any danger. Do not use it if in any doubt, but contact our customer service team. To protect against damage during transit, your appliance is packaged. ...
Page 15
Dehumidifying mode Press “MODE” to select dehumidifying mode, DEHUMIDIFY mode indicator turns In dehumidifying mode, the sleeping function cannot be used, and the fan speed is low. Note: The user should connect the hose to the drain outlet at the bottom of the unit when using this mode.
Page 16
When the unit operates in the cooling function or drying operation, the ambient temperature sensor senses the evaporator coil temperature. If it is below -1°C, the compressor will stop operating for 10 minutes Once it is up to 7℃, the unit restarts in cool operating mode. Overflow Protection Function When the water in the water pan exceeds the warning level, the machine will automatically sound an alarm, and the "FULL"...
Page 17
Continuous Drainage For continuous operation or unattended operating in dehumidifier mode, please connect a hose to the unit at the bottom drainage plug. NOTE: to operate permanent drainage you need to allow the water to drain outside via gravity. When the appliance is in cooling or dehumidifying mode, the continuous drainage house needs to be inserted into the bottom drain hole.
CLEANING and MAINTENANCE This appliance contains no user-serviceable parts. Any servicing requiring disassembly other than cleaning must be performed by a qualified appliance repair technician. Before Cleaning Before unplugging the unit ensure all controls are set off. When not in use or before cleaning, always disconnect the appliance from the mains supply.
Page 19
Rinse the air filter under running Switch off the unit and remove water. the two air filters. Warning!!! Do not touch the evaporator surface with bare-hand, or may cause injury to your fingers. Storing the Air Conditioner If the machine will be unused for a long period store your appliance and all its accessories and instruction manual in a safe and dry place.
TROUBLESHOOTING If a condition listed below occurs, please check the following items before calling customer service. Symptom Inspection Solution Insert the power cord securely into Check the power connection is the wall secure. Outlet. The unit is ...
Page 21
SAFETY PRECAUTIONS ON SERVICING Please follow these warnings when to undertake the following when servicing an appliance with R290. Checks to the area Before beginning work on systems containing flammable refrigerants, safety checks are necessary to ensure that the risk of ignition is minimized. For repair to the refrigerating system, the following precautions shall be complied with before conducting work on the system.
Page 22
Ventilated area Ensure that the area is in the open or that it is adequately ventilated before breaking into the system or conducting any hot work. A degree of ventilation shall continue during the period that the work is carried out. The ventilation should safely disperse any released refrigerant and preferably expel it externally into the atmosphere.
Page 23
Cleaning up refrigerant General Measures: Gas/vapour is heavier than air and may accumulate in confined spaces, particularly at or below ground level. Eliminate every possible source of ignition. Use appropriate personal protection equipment (PPE). Evacuate unnecessary personnel, isolate, and ventilate the area. Do not get in eyes, on the skin, or clothing.
Need help?
Do you have a question about the PL617 and is the answer not in the manual?