5- Installation

Rules of installation:

Electric and hydraulic connections must be carried out according to standards
in effect (NF C 15 100, CE I 364).
The machine must be installed outside.
The machine must be posed on its ant vibratory studs, set and lying flat and on a
massive base (concrete slab); this base must have a sufficient height to prevent any
entry of water by the bottom of the machine. Height must be adjusted to fit the
connector collecting the condensates.
The obstacles such as wall and vegetation must be separated from the machine as
indicated on the diagram below.
Do not to install the Heat pump in a confined place (the fan would recycle its air and
the Heat pump would be down performance).
The fan should not blow towards the windows or crossing point.
Safety distance between the swimming pool and the foot bath: the fitter must
imperatively refer to the standard C15-100 section 702; the machine should not be
installed in volume 1 surrounding the swimming pool but at least in volume 2 so at a
distance of 3 m minimum of the swimming pool and foot bath.
Other precautions of installation:
- Do not to install the machine near a way with circulation of car in order to avoid
mud projections.
- Avoid directing blowing against dominant winds.
- If the machine is intended to be used in winter, put it in a place protected from the
falls of snow.
- The machine must be able to be supervised in order that children do not play
around