  • Page 1 WallBox User manual V 2.0 Mod. 7 Kw - C K 7 - 1 3 2 11 Kw - CK11-316 22 Kw - CK22-332...
  • Page 2 Celektron charging stations in alternating current for vehicles electric of the CK series User Manual...
  • Page 3 TO A DANGER OF DEATH, INJURY AND DAMAGE TO THE DEVICE, CELEKTRON CANNOT ACCEPT ANY LIABILITY FOR CLAIMS RESULTING FROM THIS. THIS DOCUMENT IS PROPERTY OF CELEKTRON S.R.L., ANY INFORMATION CONTAINED HEREIN SHALL BE NEITHER COPIED OR DISCLOSED TO ANY THIRD PARTY...
  • Page 4 CK-series AC EV Charging Station User Manual INDEX 5.2 Unboxing 1. ABBREVIATIONS 5.3. Installation preparation 2. SAFETY NOTES 5.4. Installation Steps 2.1 Safety Signs 2.2 Environment 6. OPERATION 2.3 Installation 6.1. Power on 6.2. Human-machine interface 2.4 Operating 2.5 Maintenance 6.4.
  • Page 5 CK-series AC EV Charging Station User Manual ABBREVIATIONS Abbreviations Description International Electrotechnical Commission Electrical Vehicle, this can be BEV (battery EV) or PHEV (plug-in hybrid EV) EVSE Electric Vehicle Supply Equipment [IEC61851-1] KiloWatt (unit of Power) Ampere (unit of Current) Volt (unit of Voltage) Hertz (unit of Frequency) Liquid Crystal Display...
  • Page 6: Safety Notes

    CK-series AC EV Charging Station User Manual 2. SAFETY NOTES 2.1. Safety signs The following warning signs, mandatory signs and information signs are used in the user manual, and in the CK EV Charging stations: Warning Signs CAUTION: Warning of electrical hazards This sign is intended to alert the user that severe personal injury or substantial property damage can result if the device is not operated as requested.
  • Page 7 CK-series AC EV Charging Station User Manual Mandatory signs Use protective footwear Must wear a safety helmet 2.2. Environment EV charging station should be installed on the incombustible materials such as metal; The charging station for electric vehicles must not be installed in areas that contain explosive gases;...
  • Page 8 CK-series AC EV Charging Station User Manual 2.3. Installation Safety protection must be worn when installing the EV Charging station. otherwise, hazardous electric shock may result. Make sure input power supply is entirely disconnected before wiring; otherwise, hazardous electric shock may result. Earth terminal of the EV Charging station must be grounded securely;...
  • Page 9 CK-series AC EV Charging Station User Manual 2.4. Operating Strictly forbidden for minors or persons of restricted capacity to approach the charging station to avoid injury. Forced charging is strictly forbidden when the electric vehicle or charging station fails. "emergency stop" button of the charging station, and immediately stay away from the charging station.
  • Page 10 CK-series AC EV Charging Station User Manual After replacing main PCBA, parameters must be adjusted and matched before operation; otherwise, property loss may result. It is recommended that routine safety inspection visits to charging station be conducted at least once a week. Keep the charging connector clean and dry and wipe it with a clean dry cloth if soiled.
  • Page 11 STANDARDS 3.1. Reference standards Celektron’s CK-series AC EV charging stations are designed according to IEC standards. The standards of this series of products include: IEC 61851-1:2017, Electric vehicle conductive charging system - Part 1: General requirements. IEC 62196-2:2016, Plugs, socket-outlets, vehicle connectors and vehicle inlets – Conductive charging of electric vehicles –...
  • Page 12 3.4. Charging connector The charging connector of Celektron’s CK-series products meet IEC 62196-2, type 2 (Schematic The charging vehicles of Celektron’s CK-series products are the electric vehicle with type 2 (a) 1-phase type 2 plug (b) 3-phase type 2 plug...
  • Page 13: Product Informations

    PRODUCT INFORMATIONS 4.1. General informations Welcome to use your new Celektron’s CK-series AC EV Charging station. The shape & dimensions of CK-series AC EV charging station shown as Fig. 4-1. Fig. 4-1 The Shape & Dimensions of CK-series Wallbox CK-series AC EV charging station provides a friendly HMI, with the corresponding control, metering and communication functions, belongs to the special AC power supply device for EV.
  • Page 14 CK-series AC EV Charging Station User Manual Ethernet Main PCBA RFID Charging Connector RCCB 4.3. Product series Maximum output rated current 16: 16A; 32: 32A Phases number: 1: 1-phase; 3: 3-phases Celektron Wallbox shell code...
  • Page 15 CK-series AC EV Charging Station User Manual 1-phase and 3-phase products Model CK7-132 CK11-316 CK22-332 Maximum Rated Power Maximum Rated Current RCCB recommended Type B, 25A, 3-Pole Type B, 25A, 5-Pole Type B, 40A, 5-Pole Input cable conductor 3x6mm , copper...
  • Page 16 CK-series AC EV Charging Station User Manual Mechanical parameters Mounting Charging connector IEC 62196-2, Type 2 Charging cable length Net Weight Front panel: Black, Tempered Glass Color & Material Back cover: Gray, Metal Plate Enclosure rated IP54 Ambient conditions Storage temperature -40 ~ 75°C Operating temperature -30 ~ 55°C...
  • Page 17 4.5. Nameplate the content is shown as Fig. 4-3. AC EV Charging Station Model No.: CK7-132 Input Phase: 1P + N + PE Rated Input: 230VAC, 50/60Hz, 32A Rated Output: 230VAC, 50/60Hz, 32A Rated Power: 7kW Connector: IEC 62196-2, Type 2...
  • Page 18: Installation Instruction

    CK-series AC EV Charging Station User Manual INSTALLATION INSTRUCTION Transport or movement When transporting or moving, please pay attention to the following points to ensure product safety: 5.2. Unboxing In the box, there is a packing list, which includes: 2 RFID cards, 1 user manual, When unboxing, please ca rm the following points:...
  • Page 19 Operator must always notice safe protection such as wear protective footwear, wear goggles, otherwise it may occurs personal injuries. Tools for installation Prepare the following tools before installing the Celektron’s CK-series AC EV charging station. Sr No. Tool’s Name Schematic Picture...
  • Page 20 CK-series AC EV Charging Station User Manual Crimping pliers Press cables terminals Cross screwdriver Fastening screws Ambient Refer to 2.2 for more safety notes. The electrical power supply cable must be prepared. Please refer to page 44 to select the power cable. In order to ensure the long-term stable operation of the product, it is recommended to avoid installing charging stations in extreme weather as far as possible, especially low or high ambient to ensure good ventilation condition, you should mount the charging station vertically.
  • Page 21 CK-series AC EV Charging Station User Manual Installation Steps Install the attachment height, spaced 130mm×70mm apart, and secure the mounting accessories to the wall with the expansion screw contained in the package. Fig. 5-2 Install the attachment Step 2: Fix the Wall-hanging accessories Wall-hanging accessories Input cable...
  • Page 22 CK-series AC EV Charging Station User Manual As shown in Fig. 5-5, open the terminal cover, pass the prepared power cable through the input cable interface, connect each cable to the input terminals according to the terminal label. Fig. 5-5 Wiring the input power cable If the CMS need to be connected through the network cable, put the network cable through the Input cable interface, then crimp the RJ-45 head, and then insert it into the Network interface.
  • Page 23: Operation

    CK-series AC EV Charging Station User Manual OPERATION 6.1. Power on indicator light is on, and the charging station enters the standby state. 6.2. Human-machine interface HMI information nterfaces. ① ④ LED indicators Emergency stop button ② ⑤ Charging connector ③...
  • Page 24 CK-series AC EV Charging Station User Manual LED indicators The LED indicators on the panel are used to indicate the status of the charging station and the various combinations of indicators are described as below. Power Connect Charging Fault Connection GREEN GREEN YELLOW...
  • Page 25 CK-series AC EV Charging Station User Manual Area n. Icon Status Area No icon Connected to the router via WiFi Exchanging data with CMS via WiFi Connected to the router via Ethernet Exchanging data with CMS via Ethernet Area S/N: 88888888888888 Serial number of the charging station Area Standby...
  • Page 26 Then contact our after sell service center or your supplier. Celektron’s When the charging station is in standby state, please plug the charging connector in the empty socket...
  • Page 27 CK-series AC EV Charging Station User Manual Step 1: connect to WiFi hotspot Keep your laptop in a state where it can connect to WiFi hotspots. Within two minutes after power on, the hotspot with a name is similar to "EVSE-12345678" in the "WiFi network" of the laptop. It is no password to connect the hotspot.
  • Page 28 CK-series AC EV Charging Station User Manual Type the correct login password to enter the page shown in Fig. 6-8. Please contact the supplier for the login 12345678 by default password (usually Enter your WiFi name Enter your WiFi password Select the start charging mode: YES - Plug and play NO - Need to swipe RFID card...
  • Page 29 CK-series AC EV Charging Station User Manual 6.4. Start charging EV, then the “Connect” LED of the charging station lights up. Fig. 6-9 EV socket With “swipe card-controlled” charging mode, the station needs to swipe card to start. Using the APP controlled charging mode, the station needs to scan the QR code with the mobile phone to start.
  • Page 30 CK-series AC EV Charging Station User Manual 6.5. Normal recharge stopping full charge, and second, manual stoppage. the remote key of the electric vehicle, the vehicle will stop charging is not stopped, press the button of the adapter Fig. 6-11 pull adapter out the vehicle automatically.
  • Page 31 CK-series AC EV Charging Station User Manual FA U LT S H A N D L I N G A N D M A I N T E N A N C E 7. 1 . F a u l t s H a n d l i n g The charging station is automatically protected in the event of faults.
  • Page 32 CK-series AC EV Charging Station User Manual Fault code 18: Check whether the charging adapter Output shortage and its cables are damaged or wet 1xslowly, 8xfast Fault code 19: Check whether the charging connector is Output overcurrent correctly connected to the car, and check whether the 1xslowly, 9xfast on-board charger is normal Fault code 21: Make sure that the charging connector is...
  • Page 33: Warranty Agreement

    CK-series AC EV Charging Station User Manual WARRANTY AGREEMENT The scope of warranty refers to the product itself. The warranty period is 5 years. During the warranty period, the company will repair the product free of charge in case of failure or damage occurred under normal and proper use. The starting time of warranty period is the date of purchase.
  • Page 34 CK-series AC EV Charging Station User Manual...
  • Page 35 CK-series AC EV Charging Station User Manual COMPLIANCE STATEMENT OF WEE regulations. It cannot be abandoned or thrown away as a normal waste. Address: Via Gioberti, 15 , 56024, San Miniato (PI), Italy...
  • Page 36 Sede legale: Via Vincenzo Gioberti, n. 15, 56024 Sede operativa: Via Lungarno Pacinotti, 31, 56020 Telefono: +39 0571 544948 Fax: +39 0571 544948 Partita IVA: 02375390503 C.C.I.A.A. Reg. Imprese Pisa n. 02375390503 customerservice@celektron.eu social@celektron.eu info@celektron.eu sales@celektron.eu app@celektron.it...

This manual is also suitable for:

Ck11-316Ck22-332