1
The Puck Module must be identified and configured using the Control4
Composer software application. See the Composer Pro User Guide for
information about configuring the Puck Module.
2
To test/operate the Puck Module prior to configuration:
• Press and release the Identify button on the puck to toggle the load. With
a Puck Dimmer, pressing and holding the Identify button will ramp/fade
the load. The LED on the ID button will be lit when the load is on, and the
LED will be off when the load is off.
Figure 6. Puck Module with Button LED
Both auxiliary contacts are configured to toggle the load by default. If a
keypad/switch is connected to an auxiliary contact, press and release the
button to toggle the load.
The default behavior for both auxiliary LEDs is Load On = LED on, Load
Off = LED Off.
3
In the case of a short circuit or overload condition, the Puck Module has
built-in circuit protection that will put the module into a safe mode. When an
incandescent bulb burns out, it creates a momentary high-current situation
that can activate this protection. If the protection has been activated:
The LED on the Puck Module and any LEDs on connected switches will
blink once every two (2) seconds.
To reset the device:
Click the ID button on the puck, OR
Press and release the button connected to auxiliary Contact 1 (One).
If the Puck Module goes back into safe mode after resetting, the fault
condition still exists and must be addressed before attempting to reset the
Puck Module again.
When the Puck Module returns to safe mode within 10 seconds of a reset,
it cannot be reset by a single click of the ID button or auxiliary contact.
To reset the device in this case:
Click the ID button on the puck 15 times, OR
Press and release the button connected to auxiliary Contact 1 (One)
15 times.
4
Button tap sequences can be performed using either the button on the
Puck Module or the buttons attached to the auxiliary contact. When using
a latching switch, each toggle of the switch (up to down or down to up) is
treated as one (1) tap.
Function
Button on Puck
Identify
4
ZigBee Channel
7
Reboot Device
15
Factory Reset
9
Leave Mesh &
13
Reset
©2011 Control4. All rights reserved. Control4, the Control4 logo, the Control4 iQ logo and the Control4 certified logo are registered trademarks or trademarks of
Control4 Corporation in the United States and/or other countries. All other names and brands may be claimed as the property of their respective owners.
Aux. Contact 1
Aux. Contacts
1 & 2
4
N/A
7
N/A
15
N/A
22
9-4-9
30
13-4-13
Troubleshooting
1
If the load does not turn on:
• Ensure that the circuit breaker is not turned off or tripped.
• Ensure that the light bulb is not burned out and is screwed in properly.
• Ensure that the Puck Module is not in short circuit safe mode. (See Step 3
in the "Operation and Configuration.")
• Check for proper wiring (see "Sample Wiring Diagrams").
2
If the button(s) connected to the auxiliary contacts do not operate the load,
check for proper wiring (see "Sample Wiring Diagrams").
3
If the LEDs connected to the auxiliary LED terminals do not illuminate:
• Check for proper wiring (see "Sample Wiring Diagrams").
• Ensure that the LEDs are designed to operate at 220-240V.
Regulatory/Safety Compliance
To review regulatory information for your particular Control4 products, see
the information located on the Control4 website at: http://www.control4.com/
regulatory/.
Patent Information
Protected under U.S. Patents 7,336,463 and licensed under U.S. Patents 5,905,442
and 5,982,103
Warranty
For complete warranty information, including details on consumer legal rights as
well as warranty exclusions, visit www.control4.com/warranty.
About this Document
Part Number: 200-00205 Rev B, 7/29/2011

Advertisement

loading

This manual is also suitable for:

C4-sm201-z