  • Page 1 Electric Towel Warmer Model: FLB500W, FLB750W...
  • Page 2 WARNING CAUTION: Some parts of this product can become very hot and cause burns. Particular attention has to be given where children and vulnerable people are present. Children of less than 3 years should be kept away unless continuously supervised. Children aged from 3 years and less than 8 years shall only switch on/off the appliance provided that it has been placed or installed in its inten-ded normal operating position and they have been given supervision or instruction concerning use of the appliance in a safe way and unders-tand the hazards involved.
  • Page 3: Specifications Of The Appliance

    Voltage: 230 V ~ 50 Hz Insulation class: II Protection class: IP24 Product dimension Item NO. POWER Horizontal tube quantity L(CM) W(CM) H(CM) FLB500W 500W 2+2+4 FLB750W 750W 3+4+5 2. GENERAL INFORMATION Storage and maintenance: Avoid storing the appliance in places at risk of freezing. Protect from frost.
  • Page 4: Wall Mounting

    The appliance must be installed in such a way that the switch, electronic controls and other control devices cannot be touched by someone in the bath or shower. The electronic controls and other control devices must always be in volume 3. The appliance must not be connected with a plug. 3.1 WALL MOUNTING The screws and wall plugs supplied are suitable for solid walls.
  • Page 5 Picture Name Quantity Product Bracket part Screw Bracket part Bracket part Screw Bracket part Screw Screw Fig. 2...
  • Page 6: Electrical Connections

    Fig. 4 The minimum recommended distance between the bottom and the floor is 600 mm. 2, With a pencil, mark the four holes on the wall according to Fig.3(FLB500W) and Fig.4(FLB750W), drill and insert the screw 9. 3, Fix part 7 by using screw 6.
  • Page 7: Regulation And Operation

    The power supply line must be protected by the same differential protection device. Permanently connected appliances must be connected using a connector block placed within a proper junction box. When installing the appliance in damp rooms (kitchen, bathroom), the point of connection with the household mains must be at least 25 cm from the floor.
  • Page 8: Operation

    4.2 OPERATION: 4.2.1 Select mode: Each time press button, you can select confort , ECO , anti freeze , timer , booster in sequence. 4.2.2 Comfort mode: Press and select to confort mode . Default temperature is 19℃. Temperature range from 5℃ to 30℃. Press to set temperature.
  • Page 9 4.2.5 Time set and Week timer mode: Press and select to timer mode , then you can set hour, minute, week(1 to 7 means Monday to Sunday) and select running program(P1 to P9) for week. Please note there are 9 default programs(P1 to P9), and if you want, you also can change these 9 programs by yourself.
  • Page 10 This show the time is 12:05, and the red arrow indicate it run comfort mode, and comfort icon also bright. Default P1-P9 setting as below: P1: comfort mode 6:00 to 22:00, the others all ECO mode. P2: comfort mode 19:00 to 6:00, the others all ECO mode. P2: comfort mode 6:00 to 9:00 and 16:00 to 22:00, the others all ECO mode.
  • Page 11 Press and select to booster mode . It can keep heating from 0.5 to 2 hours, and press to change hours.It will return to previous mode after booster finished. 4.2.7 Open window function: If you open a window widely in the space where the towel warmer is located, a sensor will detect the sharp drop in temperature.
  • Page 12 5. ERP table Information requirment for the electric local space heaters Model identifier(s): FLB500W Item Symbol Value Unit Item Unit Heat output Type of heat input, for electric storage local space heaters only (select one) manual heat charge control, with...
  • Page 13 Information requirment for the electric local space heaters Model identifier(s): FLB750W Item Symbol Value Unit Item Unit Heat output Type of heat input, for electric storage local space heaters only (select one) manual heat charge control, with Nominal heat output Pnom 0,75 integrated thermostat...
  • Page 14: Maintenance And Cleaning

    6. MAINTENANCE AND CLEANING If technical problems arise, contact a qualified professional (recognised or authorised by the dealer or manufacturer) or your local dealer. All operations on the appliance must be carried out by a qualified professional who before performing maintenance must make sure the appliance is turned off, cold and disconnected from the household mains.