This manual provides instructions on installation, operation, cleaning and routine. Information contained in this manual may be subject to change. Please check online or contact your local Spaceman distributor for continued updates and detailed information about your Spaceman machine.
6. Place the machine in its final location according to the Installation Requirements. Check for shipping damage Inspect the machine for any shipping damage. If you find any, contact Spaceman Technical Service immediately after unpalletizing. Our technicians will help you assess the damage and determine the appropriate action prior to accepting the delivery.
Getting to Know Your Machine Machine Parts Dispensing Door Star Cap Beater Rod Beater Guide Door Gasket Hand Screws Dispensing Handle Beater Beater Seal Draw Valve with O-Rings Brush Kit Air Tube Hopper Lid Front Drip Tray with Internal Drip Tray O-Ring Removal Tool Splash Shield Brush Kit...
Circuit Breaker or Wall Receptacle before If you require an alternative refrigerant, please switching on or plugging in the machine. call Spaceman Technical Support for a list of compatible alternatives for your compressor. 1PH, 50/60HZ Machine placement requirements...
For optimal machine performance and many years of efficiency and reliability from your machine, Spaceman recommends cleaning and sanitizing the machine and its parts daily. The machine comes equipped with a brush kit specifically designed to efficiently and properly clean the machine.
Routine Maintenance Drain Product NOTE: To expedite draining, turn off machine 30 minutes prior to softening product. To expedite process, keep a bucket nearby to temporarily store removed parts. CAUTION: Never use warm water when rinsing the machine to prevent damage. 1.
Routine Maintenance Disassemble Parts NOTE: Prepare dishwashing area prior to disassembly, use bucket to temporarily store large removed parts and a small container for O-rings, and have a towel nearby to capture excess water. CAUTION: Always separate O-rings and gaskets from metal parts to prevent damage while washing.
Routine Maintenance Wash Parts 1. Verify power switch is in the OFF position. 2. Use the large brush and cool water to thoroughly clean inside the cylinder; be sure to scrub the back of the cylinder and verify the cylinder is free of ALL product. 3.
Rotate to lock in place, make sure the beater fully inside. 3. INSTALL DISPENSING DOOR a. Place O-rings on draw valve; coat all ring areas with Spaceman lubricant. b. Insert draw valve into dispensing door. c. Install dispensing handle. Insert left part first.
Routine Maintenance Sanitize IMPORTANT: After sanitizing the machine, DO NOT rinse or touch areas that have been sanitized. Product must be added immediately. If new product will not be added immediately, rinse machine with clean water and loosen door hand-screws to allow cylinder to air-dry.
Frozen Prodcut Add product to machine NOTE: The mix-low lights illuminate when a hopper is low on product mix and automatically de-illuminate when machine is filled. 1. Verify machine has been recently sanitized (within 1 hour); if machine has not been recently sanitized, verify door hand-screws are tight, and perform sanitizing steps (Page 10).Thoroughly mix and prepare at least 7.57 liters (2 gallons) of product according to...
Frozen Product Machine power reset IMPORTANT: Machine shuts down automatically if cylinder experiences freeze-up (usually because the viscosity is set too high for the selected product) to prevent motor damage. Use the green reset button to return the machine to normal operation. Proper Machine Reset CAUTION: If machine makes any 1.
1. Allow at least 1 hour after adding new mix for hopper temperatures to stabilize. 1. Stop machine use, drain product with 2. Call Spaceman Technical Support. machine powered OFF; clean and inspect parts. 2. Replace wearable parts at least once every Problem: Hopper is freezing 3 months.
Page 15
Troubleshooting Problem: Product leaks excessively Problem: Machine Shuts down from dispensing door spout Automatically Probable Cause Probable Cause 1. Improper or inadequate lubrication of draw Cylinders are experiencing freeze-up due to valve and draw valve O-rings. 1.Viscosity set too high 2.
Need help?
Do you have a question about the 6218 and is the answer not in the manual?