AquaCore User Manual The Next Generation in Super Energy Efficient Hot Water Heating Designed and manufactured in New Zealand by Black Diamond Technologies...
CONTENTS Features Features ..............................Page 1 Smart Operation ............................Page 2 Mandatory Legionella Control ........................ Page 2 Low Usage Conditions ..........................Page 2 Modes ..............................Page 2 Interface Control Panel ............................Page 3 Power Button Features ..........................Page 3 Internet Connection ..........................Page 3 Menu Structure ............................
AQUACORE | Features AquaCore Features The Black Diamond AquaCore has many user-friendly intuitive functions and features including: Starting Features: • Manual Power On/Standby • Smart Meter Interface • 7 Day Programmable Timer • Ripple Feed Power Management Compatible • Automatic Reheat Automatic switching to hot water cylinder’s electric...
Unit Activation PLEASE NOTE: The AquaCore System is either turned on by the user or it will Cylinder thermostat must be set to 60°C. automatically power on from Standby when: • The power is initially connected or recovers from a Low Usage Conditions power outage.
AQUACORE | Interface Control Panel Power Button Features The AquaCore Controller is an easy to use 4 button control On/Standby panel with a backlit LED display which automatically lights • Press the power button to turn the system on. up when a button is pressed. Once installed the unit should not require adjustment outside use of the 7 Day Timer.
ON MAC: 801212121212 EXIT EXIT REM ID: REM ID: 1234567891 1234567891 OTHER NON SPECIFIC OTHER NON SPECIFIC DIAGNOSTIC MENUS DIAGNOSTIC MENUS WATER METERING WATER METERING MENU MENU SERVICE DIAGNOSTICS SERVICE DIAGNOSTICS EXIT EXIT MENUS MENUS EXIT EXIT AQUACORE – User Manual...
MAR 11 2022 20/08/22 12:55 ECON0 20/08/22 12:55 ECON0 The standby screen displays the following information: As described previously there are three modes the AquaCore can be set to: Economic (ECON), Disinfect (DISIN) and • Current status Normal (NORM). • Timer To change the AquaCore operating mode, use the •...
Page 8
MENU to enter the Time/Date Summer Menu. • Press MENU SELECT The AquaCore System is set to 62°C as factory standard. • Scroll to the Summer/Winter Time Screen by However the set temperature adjustment range is from Down or 58–63°C.
Page 9
Off 17:00 SERVICE DIAGNOSTICS SERVICE DIAGNOSTICS MENU MENU The AquaCore System has a total of 7 timers. Each timer can be set in one of four ways: 1. As an Operational Window Timer to enter the Service Diagnostics Menu. • Press...
Page 10
– Off Timer set the hour and minute to match the same time chosen previously e.g. both time selections should match. • Press to confirm and end the timer MENU SELECT setting process. AQUACORE – User Manual...
Water Leaks The AquaCore System has two levels of fault codes: In the event a water leak is discovered, immediately turn off the AquaCore System. Proceed to call your plumber or Level 1 technical/service agent. • Minor faults which are automatically self-corrected.
Page 12
AquaCore System by turning off the water to the Storage Tank Isolation Valve, ensuring that the cold and hot water supply valves to the AquaCore are open, press the menu button to open the motorised ball valve and turn on a hot tap until the flow has no air bursts. Turn off the hot tap and open the Storage Tank Isolation Valve.
IA too high >= 3A Call for service refer to note 1 Possible refrigerant FLT10 Call for service Turn off power and water taps to AquaCore gas leak Water too cold to defrost possible water FLT11 Defrost WE < 4.0 System will retry...
When installing, relocating, or servicing the unit, make sure that no substance other than the specified refrigerants (R32 in the outdoor unit and R134A in the AquaCore unit) enters the refrigerant circuit. • Any presence of foreign substance such as air can cause abnormal pressure rise and may result in explosion or injury.
Page 15
If a leakage of refrigerant is found which requires brazing, all of the refrigerant shall be recovered from the system, or isolated (by means of shut off valves) in a part of the system remote from the leak. Removal of refrigerant shall be according to Clause DD.9. AQUACORE – User Manual...
Page 16
Only electric heating to the compressor body shall be employed to accelerate this process. When oil is drained from a system, it shall be carried out safely. AQUACORE – User Manual...
Outdoor Unit Type Refrigerant Quantity Operation Range Heating [°C] -15 / +45 Outdoor Ethernet connection (Standard), Optional Water Inlet Temperature Probe, Optional Water Outlet Temperature Optional Extras Probe, Optional Water Usage Meter, Optional Water Flow Meter AQUACORE – User Manual...