Sfere DASv10 User Handbook Manual

Programmable setpoint detectors

Advertisement

Quick Links

PROGRAMMABLE SETPOINT DETECTORS
DASv10 / DASCv10
version 05.x
LCD µconsole
SFERE
Software SlimSET
Société Française d'Etudes et
de Réalisations Electroniques
Tél. : 04 78 16 04 04 - Fax. : 04 78 16 04 05
Tel. Intern. : 33 4 78 16 04 04 - Fax Intern. : 33 4 78 16 04 05
User handbook
siège : Route de Brindas - Parc d'Activité d'Arbora - N°2
69510 SOUCIEU EN JARREST - FRANCE

Advertisement

loading
Need help?

Need help?

Do you have a question about the DASv10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Sfere DASv10

  • Page 1 PROGRAMMABLE SETPOINT DETECTORS DASv10 / DASCv10 version 05.x LCD µconsole SFERE Software SlimSET Société Française d’Etudes et de Réalisations Electroniques Tél. : 04 78 16 04 04 - Fax. : 04 78 16 04 05 Tel. Intern. : 33 4 78 16 04 04 - Fax Intern. : 33 4 78 16 04 05 User handbook siège : Route de Brindas - Parc d’Activité...
  • Page 2 3 . CONNECTINGS France 4 . PROGRAMMING declares that the following products: Name: Programmable setpoint detectors Measure screen Type: DASv10, DASCv10 Menu MAIN Menu DIR.FCT comply with the following directives and standards: Menu INPUT Menu DISPLAY The EMC Directive 2014/30/UE...
  • Page 3 It must be mounted, connected and implemented respecting The products DASv10 and DASCv10 are setpoint detectors, fully programmable the current specific regulations, by a qualified technician, trai- either with the µconsole or by PC via the configuration software and a standard USB/ ned to the safety regulations, who will have read this manual.
  • Page 4 Features of the inputs Type Features of OUTPUTS Types of Measure range Permanent Intrinsic Input INPUTS adjustable from: overload error impedance 2 setpoints per relay configurable over the whole MR. 2 change-over relays Hysteresis programmable from 0 to 100%. Time delay programmable from 0 to 999.9 sec. mA (1) -2 to +22mA (U) ±100mA...
  • Page 5 2. SPACE REQUIREMENTS Measure: • Standard sampling time: 100 ms option F: programmable at 1 ms, 16.6 ms, 20 ms, or 100 ms 136 mm (with µconsole) 22,6 • Common mode rejection rate: 130 dB numbering of 122 mm (without µconsole) the terminals: Serial mode rejection rate: 70 dB 50/60 Hz 1 2 3 4...
  • Page 6 This µconsole for clipping on the front face allows the visualisation of the measure or occasional modifications of the programming via its tactile keyboard. It also allows the teleloading of a programming file to other products of the SFERE range. It must be installed in a protecting enveloppe conform with the EN 60079-15.
  • Page 7 Measure screen Unlocking of the keyboard Description Locked keyboard symbole. After 30 sec of inactivity of the keyboard in measure mode, it will be blocked Tactile screen. Press Display of the measure, of the error messa- in order to prevent any the measure screen for ges (eg.: sensor break, scale overrange etc.) unintentional pressing.
  • Page 8 Moving through the list menus: Entering of a value: Eg.: CODE CODE CODE READ READ READ 0000 0000 2000 INPUT INPUT INPUT DISPLAY DISPLAY DISPLAY MODIF VALID VALID CONF ADV CONF ADV CONF ADV RELAYS RELAYS RELAYS Press SAFETY SAFETY SAFETY MODIF to Use the...
  • Page 9 MEASURE SCREEN DIR.FCT MIN MAX 120.3 Menu of the functions with direct MES DIR access see page 12 Press the screen in measure mode to CLR ALR DIAG PROG REL access the menu of the direct functions FILE 1 ADJUST or the display of the details of the lat- BRIGHT ched self-diagnosis errors: ERxxx...
  • Page 10 MAIN READ CFG CODE PROGRAM SET CODE 0000 SIMULAT µ MODIF CON.MEM FUNCTION LANGUAGE SENS.KEY ABOUT if code DISABLE in MANUAL menu SET CODE...
  • Page 11 MAIN if access blocked by code READ CFG SIMUL PROGRAM SENSOR CODE SIMUL SET CODE 000.0 SIMUL menu simulation SIMULAT 0000 SENSOR µ (unit) INFO CON.MEM DISPLAY MODIF SENSOR FUNCTION 000.0 MODIF (unit) LANGUAGE SENS.KEY DISPLAY 000.0 ABOUT (unit) MANUAL Enter the value corres- SIMUL...
  • Page 12 Reading of the configuration file stored MENU inside the µconsole memory (same orga- nigramme as for the instrument). INPUT MAIN DISPLAY Note (A) READ CFG if access blocked by code CONF ADV PROGRAM RELAYS μ CONS CODE SET CODE SAFETY MEMORY SIMULAT SET CONS...
  • Page 13 menu MEASURE SCREEN DIR.FCT DIR.FCT MIN : MIN MAX 0000 120.3 MES DIR MAX : CLR ALR 0000 PROG REL Functions with direct access FILE 1 (unit) ADJUST BRIGHT Press the key CLR MIN MAX To simplify the use, some functions can be accessed in LIGHT to delete the recorded min MIN MAX...
  • Page 15 menu INPUT menu programming (or reading) CURRENT INPUT PROG of the input 0-20mA INPUT CURRENT 4-20mA DISPLAY VOLTAGE CONF ADV TEMPERA -/+ 20mA OTHER SC RELAYS RESISTOR SAFETY POTENTIO SET CONS other current down see note (A) and up scale EXIT CURRENT DS.INP...
  • Page 17 menu No display scale (the output parameters will be programmed in physical DISPLAY PHYSICAL PROG magnitude according to the input type (V, mA, Ω etc.). DISPLAY DISPLAY INPUT PHY DISP DISPLAY PHY UNIT CONF ADV D.POINT Menu if PHY menu programming (or DISP = YES RELAYS DS DISP...
  • Page 18 transfer function menu ADVANCE ADVANCE SPECIAL CONF ADV PROG NB PTS CONFIG CONFIG LINEAR INPUT DISPLAY TRANSFER LINEAR NB PTS menu programming (or reading) CONF ADV MODIF CUT OFF LIN SPE ABSCISSE of the advanced functions RELAYS TIME ACQ ROOT ORDINATE SAFETY FILTER...
  • Page 19 TRANSFER LINEAR : Linear function ROOT : extraction of the square root √ of the measure brought back in % of the programmed measure range. Eg.: Input 4-20mA => 12mA gives 0.707 (√0,5) The function square root tends to amplify the input signal background noise when getting near zero.
  • Page 20 menu RELAYS ALARM 1 ALARM 1 PROG ACTIV RELAYS Relay not active M.ACTIV INPUT RELAY 1 FCT MODE Programming of DISPLAY RELAY 2 DISABLE SET SPT1 the next relay CONF ADV ACTIVATE SET SPT2 menu programming (or reading) of the RELAYS Menu present HYSTERES...
  • Page 21 ALARM 1 M.ACTIV FCT MODE ALARM 1 Status of the LED SET SPT1 SET SPT2 when the relay coil is HYSTERES supplied LED OFF DELAY AL LED LED ON MEMO AL MESSAGE ALARM 1 M.ACTIV FCT MODE SET SPT1 SET SPT2 HYSTERES DELAY AL LED...
  • Page 22 • Mode setpoint setpoint setpoint SPI.X SPI.X Legend: coil supplied OFF coil not supplied • Mode window setpoints setpt setpt SP1.X SP2.X SP1.X SP2.X HYSTx • Setting of the hysteresis The hysteresis is activated on switching from led ON to led OFF; that is to say on switching out of alarm, since the led represents the alarm status.
  • Page 23 menu PROG RUPTURE Only if input mV/TC SAFETY DETECT SAFETY INPUT DETECT RUPTURE ENABLE Disconnection of the sensor DISPLAY RELAY 1 break detection DIAGNOSI DISABLE CONF ADV RELAY 2 menu programming (or reading) of the RELAYS safety functions SAFETY SET CONS Sensor break / Self-diagnosis EXIT RELAYx...
  • Page 24 SAFETY SAFETIES : • Sensor break The sensor break can be detected on the inputs mV, Tc, Pt100, Ni100, resistance (<400Ω) and current if the down and up scale <3.5mA. On the µconsole: the message OPEN appears On the converter: The LED ON blinks (approx. 4Hz) Disconnection of the sensor break detection: (if input mV or temperature) The sensor break detection can be disconnected in order not to disturb some calibrators which may be sensitive to the rupture detection current.
  • Page 25 menu Setting of the BRIGHT LIGHT PROG µconsole contrast and SET CONS µ CONS INPUT LEVEL 1 LEVEL 1 brightness DISPLAY LEVEL 2 LEVEL 2 BRIGHT CONF ADV LIGHT menu programming (or reading) of the RELAYS LEVEL 10 LEVEL 10 SENS.KEY SAFETY functions concerning the µconsole...
  • Page 26 µ CONS Mode idle of the µconsole BRIGHT after 10 min. of inactivity IDLE LIGHT MODE SENS.KEY IDLE OFF LANGUAGE IDLE ON IDLE MOD TOUCH F1 TOUCH F2 PROG INPUT µ CONS DISPLAY KEY Fx CONF ADV BRIGHT RELAYS MIN MAX LIGHT SAFETY DIR MES...
  • Page 27 menu PROG PROG INPUT INPUT DISPLAY DISPLAY CONF ADV CONF ADV Entering of the name given RELAYS RELAYS to the configuration (8 cha- SAFETY SAFETY racters max.) displayed on SET CONS SET CONS the measure screen FILE 1 EXIT EXIT MODIF menu EXIT...
  • Page 28 5. ERROR MESSAGES Upper or lower electrical Measure in overrange 2000 ---- overstepping of the input Sensor break OPEN Displayable value overload. Self-diagnosis error Value set out of range ERR1 ERxx (see p23) 5.1 Blinking of the led ON: Fast blinking (approx. 4 Hz): ERxx Self-diagnosis active (display ) OR...