Advertisement

Quick Links

Machine Translated by Google
operating manual
garden pump
GPI 5548
GPI 5548

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GPI 5548 and is the answer not in the manual?

Questions and answers

Summary of Contents for CleanCraft GPI 5548

  • Page 1 Machine Translated by Google operating manual garden pump GPI 5548 GPI 5548...
  • Page 2: Table Of Contents

    Customer Service............ 3 item number garden pump 1.3 Limitation of liability........3 GPI 5548 7521400 2 Security ..............3 2.1 Explanation of symbols......... 3 2.2 Responsibility of the operator ......4 2.3 Personnel qualifications ........ 5 2.4 Personal protective equipment ..
  • Page 3: Introduction

    1.3 Limitation of Liability You have made a good choice with the purchase of All information and instructions in the operating the CLEANCRAFT garden pump. instructions have been compiled taking into account the applicable standards and regulations, the state of...
  • Page 4: Security

    Machine Translated by Google security 2.2 Responsibility of the operator WARNING! The operator is the person who operates the machine himself for This combination of symbol and signal word indicates a commercial or economic purposes or lets a third party use it and potentially dangerous situation which, if not avoided, will bears the legal product responsibility for the protection of the result in death or serious injury.
  • Page 5 Machine Translated by Google security 2.3 Personnel Qualifications Manufacturer: Certain work may only be carried out by the The various ones described in this guide manufacturer's specialist staff. Other personnel are Tasks place different demands on the qualifications not authorized to carry out this work. Our customer of the people who are entrusted with these tasks.
  • Page 6 Machine Translated by Google security - Never work under the influence of illnesses that affect concentration, overtiredness, drugs, alcohol ATTENTION! or medication. The pumped liquid can be hot and under high - Do not start the water pump until the pump pressure.
  • Page 7: Pump

    Machine Translated by Google Intended Use 2.6 Safety markings on the Was ATTENTION! water pump Any modification of the device is prohibited. The Safety markings and instructions are attached to the water modification may result in fire and injury, including pump (Fig.
  • Page 8: Nameplate

    If you discover damage to the water pump, report this immediately to the transport company or dealer. 6.2 Transportation ATTENTION! Fig. 2: Nameplate GPI 5548 Let the water pump cool down completely and drain it completely of water. 5 Specifications The water pump may only be transported in an upright position.
  • Page 9 Mistake, pressure setting, leakage, temperature On/off switch Pump is running or in Standby mode Fig. 3: Description of GPI 5548 1 display 2 suction port 3 filler necks manual operation, the Pump is 4 suction connection switched off 5 water drain port...
  • Page 10: Accessories

    Machine Translated by Google device description 7.1 Accessories When the user needs water, manual intervention is required, press the power button - Suction hose 7 meters 1" (green); When the user does not use water, press the power Article number: 7531001 button (red) to prevent the pump from starting.
  • Page 11: Installation

    Machine Translated by Google installation anti-lock function Step 1: Loosen the filler plug and fill the pump chamber with clean water. If the pump stops, the error indicator lights up and the Tighten the filler plug after the air has been error code E02 is displayed on the screen.
  • Page 12: The Pump

    Machine Translated by Google installation 8.3 Connection of the suction line Precautions for installing the water supply line ATTENTION! ATTENTION! Make sure there is sufficient distance (30 cm) between the suction line and the ground and the The diameter of the outlet pipe should be min shore to avoid damage caused by sucking in sand or as close as possible to the diameter of the outlet stones.
  • Page 13: Commissioning

    Machine Translated by Google Installation 9 Commissioning All connection lines must be absolutely tight, since leaky lines can impair the performance of the pump and cause considerable damage. It is therefore essential to WARNING! seal the threaded parts of the lines with one another and the connection to the pump with Teflon tape.
  • Page 14: Operation

    Machine Translated by Google operation 10 operation 10.1 Operation of the water pump DANGER! ATTENTION! Danger to life from electric shock! There is a risk of fatal injury if you come into contact Before starting the engine, the pump must be completely with live components.
  • Page 15: The Pump

    Machine Translated by Google operation Difference between manual mode and constant pressure mode Once the pump is running, flip the switch and the pump will toggle between constant pressure and manual control modes. The main difference is the unit displayed. Display m is constant pressure mode and X100min-1 is manual control mode.
  • Page 16 Machine Translated by Google Care, maintenance and repair/repair 11 Care, maintenance and repair/ 11.2 Maintenance and repairs repair ATTENTION! ATTENTION! Maintenance and repairs must always be carried out by skilled personnel are executed; any damaged parts are only Before maintenance work, the pump must be disconnected to be replaced with original spare parts from the power supply.
  • Page 17: Disposal, Recycling Of Old Devices

    A NOTICE! If you are unable to rectify the problems with your water 12.2 Disposal of Electrical Equipment pump yourself, please contact your nearest CLEANCRAFT dealer. Please note that electrical equipment contains a variety of recyclable materials as well as those that are harmful to the environment Please write down the following information from the water components included.
  • Page 18 Machine Translated by Google Malfunctions, possible causes and measures remedy Possible Cause Disturbance Engine will not start 1. There is no electricity 1. Use a GS compliant device to verify that voltage is present. Check mains plug. 2. Contact customer service 2.
  • Page 19: Error Codes

    Machine Translated by Google error codes 14 error codes mistake code remedy screen Possible Cause communication Contact customer service for 1. loose connection on error inspection and repair. cable; 2. Desoldering the conn drain line. Standstill 1. The pump sucks in 1.
  • Page 20: Spare Parts

    Machine Translated by Google spare Parts 15 spare parts example The bearing for the water pump GPI 5548 must be ordered. The bearing has the number 48 in the spare parts drawing DANGER! Risk of injury through the use of incorrect...
  • Page 21: 15.2 Spare Parts Drawing

    Machine Translated by Google spare Parts 15.2 Spare Parts Drawing The following drawing is intended to help you to identify the necessary spare parts in the event of service. If necessary, send a copy of the parts drawing with the marked components to your authorized dealer. Fig.
  • Page 22: Eu Declaration Of Conformity

    EU Declaration of Conformity 16 EU Declaration of Conformity Striker Machines GmbH Manufacturer/distributor: Dr.-Robert-Pfleger-Str. 26 D-96103 Hallstadt hereby declares that the following product Product group: Cleancraft® water pumps Machine type: water pump GPI 5548 Designation of the machine: Item number: 7521400 Serial number*:...
  • Page 23: Notes

    Machine Translated by Google notes 17 notes GPI series | Version 1.02...
  • Page 24 Machine Translated by Google www.cleancraft.de...

This manual is also suitable for:

7521400

Table of Contents